Microwave plasma source as an ion beam neutralizer

被引:5
|
作者
Medhisuwakul, M [1 ]
Boonyawan, D
Vilaithong, T
Engemann, J
机构
[1] Chiang Mai Univ, Fac Sci, Dept Phys, Fast Neutron Res Facil, Chiang Mai 50200, Thailand
[2] Univ Wuppertal, Microstruct Res Ctr FMT, D-42119 Wuppertal, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2004年 / 75卷 / 05期
关键词
D O I
10.1063/1.1699519
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A 13.56 MHz radio-frequency (rf) driven multicusp ion source has been developed at the Fast Neutron Research Facility. An argon ion current density of 29 mA cm(-2) can be obtained for argon gas at a pressure of 0.4 Pa, rf power of 500 W and extraction voltage of 3 kV. For such a low energy and high current of several milliampere ion beam, additional low energy electrons are needed to suppress the unwanted beam broadening by the low energy At+ ions. This can be achieved by injecting additional electrons into the Ar+-ion beam. An in-waveguide microwave plasma source, operating at a frequency of 2.45 GHz, has been constructed based on the design of Korzec et al. [D. Korzec, A. Muller, and J. Engemann, Rev. Sci. Instrum. 71, 800 (2000)], at Wuppertal. An electron current of up to 250 mA can be extracted from the source, at an absorbed microwave power of 90 W, a pressure of 8 x 10(-2) Pa, and an extraction voltage of 50 V. The neutralization source is installed downstream close to the beam line. By electrostatic interaction the plasma electrons are attracted to the positively charged ion beam forming a beam envelope. To investigate the neutralization effect, the ion extractor is modified to produce a parallel beam. A fluorescent beam profile monitor is used to measure the beam size in both cases; with and without the neutralizer. The profile of the beam can give information about the effect of the neutralizer on the ion beam. The beam current was also measured by using a Faraday cup. Results of the measurements will be presented and discussed. (C) 2004 American Institute of Physics.
引用
收藏
页码:1684 / 1686
页数:3
相关论文
共 50 条
  • [21] THE PLASMA BEAM ION-SOURCE
    LANGBEIN, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (01): : 228 - 232
  • [22] PLASMA AND ION BEAM CHARACTERISTICS OF DYNAMAG ION SOURCE
    KELLOGG, EM
    EKLUND, KE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (12): : 1338 - &
  • [23] On plasma ion beam formation in the Advanced Plasma Source
    Harhausen, J.
    Brinkmann, R. P.
    Foest, R.
    Hannemann, M.
    Ohl, A.
    Schroeder, B.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2012, 21 (03):
  • [24] Negative ion beam production by a microwave ion source equipped with a magnetically separated double plasma cell system
    Tanaka, M
    Amemiya, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 1125 - 1127
  • [25] Plasma and beam production experiments with HYBRIS, a microwave-assisted H- ion source
    Keller, R.
    Kwan, J.
    Hahto, S.
    Regis, M.
    Wallig, J.
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS, 2007, 925 : 164 - +
  • [26] Plasma source for ion and electron beam lithography
    Lee, Y
    Gough, RA
    Leung, KN
    Vujic, J
    Williams, MD
    Zahir, N
    Fallman, W
    Tockler, M
    Bruenger, W
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1998, 16 (06): : 3367 - 3369
  • [27] Schemes and optimization of gas flowing into the ion source and the neutralizer of the DIII-D neutral beam systems
    Hong, RM
    Chiu, HK
    18TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 1999, : 507 - 510
  • [28] GENERATION OF PLASMA TARGETS FOR A NEGATIVE-ION NEUTRALIZER
    HERSHCOVITCH, AI
    KOVARIK, VJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (03): : 328 - 331
  • [29] Microwave plasma source for the negative hydrogen ion production
    Mozjetchkov, M
    Takanashi, T
    Oka, Y
    Tsumori, K
    Osakabe, M
    Kaneko, O
    Takeiri, Y
    Kuroda, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 971 - 973
  • [30] A BUCKET ION-SOURCE WITH MICROWAVE PLASMA GENERATOR
    ISAIA, G
    BECKER, R
    LEUNG, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2593 - 2594