Functional slit lamp biomicroscopy for imaging bulbar conjunctival microvasculature in contact lens wearers

被引:52
|
作者
Jiang, Hong [1 ,2 ]
Zhong, Jianguang [1 ,3 ]
DeBuc, Delia Cabrera [1 ]
Tao, Aizhu [1 ,4 ]
Xu, Zhe [1 ,4 ]
Lam, Byron L. [1 ]
Liu, Che [1 ,5 ]
Wang, Jianhua [1 ]
机构
[1] Univ Miami, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Univ Miami, Dept Neurol, Miami, FL 33136 USA
[3] Hangzhou First Peoples Hosp, Dept Ophthalmol, Hangzhou, Zhejiang, Peoples R China
[4] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[5] Univ Miami, Dept Biomed Engn, Miami, FL 33136 USA
关键词
ASSISTED INTRAVITAL MICROSCOPY; SHEAR-STRESS QUANTIFICATION; BLOOD-CELL VELOCITY; FRACTAL ANALYSIS; RESOLUTION; MICROANGIOPATHY; ABNORMALITIES; CAPILLARIES; METHODOLOGY; RETINOPATHY;
D O I
10.1016/j.mvr.2014.01.005
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: To develop, test and validate functional slit lamp biomicroscopy (FSLB) for generating non-invasive bulbar conjunctival microvascular perfusion maps (nMPMs) and assessing morphometry and hemodynamics. Methods: FSLB was adapted from a traditional slit-lamp microscope by attaching a digital camera to image the bulbar conjunctiva to create nMPMs and measure venular blood flow hemodynamics. High definition images with a large field of view were obtained on the temporal bulbar conjunctiva for creating nMPMs. A high imaging rate of 60 frames per second and an similar to 210x high magnification were achieved using the camera inherited high speed setting and Movie Crop Function, for imaging hemodynamics. Custom software was developed to segment bulbar conjunctival nMPMs for further fractal analysis and quantitatively measure blood vessel diameter, blood flow velocity and flow rate. Six human subjects were imaged before and after 6 h of wearing contact lenses. Monofractal and multifractal analyses were performed to quantify fractality of the nMPMs. Results: The mean bulbar conjunctival vessel diameter was 18.8 +/- 2.7 mu m at baseline and increased to 19.6 +/- 2.4 mu m after 6 h of lens wear (P = 0.020). The blood flow velocity was increased from 0.60 +/- 0.12 mm/s to 0.88 +/- 0.21 mm/s (P = 0.001). The blood flow rate was also increased from 129.8 +/- 59.9 pl/s to 207.2 +/- 81.3 pl/s (P = 0.001). Bulbar conjunctival nMPMs showed the intricate details of the bulbar conjunctival microvascular network. At baseline, fractal dimension was 1.63 +/- 0.05 and 1.71 +/- 0.03 analyzed by monofractal and multifractal analyses, respectively. Significant increases in fractal dimensions were found after 6 h of lens wear (P < 0.05). Conclusions: Microvascular network's fractality, morphometry and hemodynamics of the human bulbar conjunctiva can be measured easily and reliably using FSLB. The alternations of the fractal dimensions, morphometry and hemodynamics during contact lens wear may indicate ocular microvascular responses to contact lens wear. (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 50 条
  • [41] ULTRASTRUCTURE OF SNAKE-LIKE CHROMATIN IN CONJUNCTIVAL EPITHELIAL-CELLS OF CONTACT-LENS WEARERS
    KNOP, E
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 771 - 771
  • [42] Corneal fluorescein and lissamine green conjunctival staining in soft contact lens wearers with dry eye symptoms
    Caffery, B
    Begley, CG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 677 - 677
  • [43] ANALYSIS OF CONJUNCTIVAL VASCULAR DENSITY IN SCLERAL CONTACT LENS WEARERS USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY
    Jesus, Jeniffer
    Dias, Libania
    Almeida, Ines
    Costa, Tatiana
    Chibante-Pedro, Joao
    CONTACT LENS & ANTERIOR EYE, 2022, 45 (01):
  • [44] A slit lamp based imaging system for measuring blood velocity in the conjunctival microcirculation of the human eye
    Koutsiaris, A. G.
    Tachmitzi, S. V.
    Kotoula, M. G.
    Karabatsas, C. H.
    Tsironi, E.
    Batis, N.
    Chatzoulis, D. Z.
    JOURNAL OF VASCULAR RESEARCH, 2006, 43 : 40 - 40
  • [45] Conjunctival impression cytology and tear fluid pH in semi-soft gas permeable contact lens wearers
    Bhatia, RP
    Kumar, M
    Singh, S
    ANNALS OF OPHTHALMOLOGY-GLAUCOMA, 1995, 27 (06): : 326 - 330
  • [46] Conjunctival impression cytology versus routine tear function tests for dry eye evaluation in contact lens wearers
    Kumar, Prachi
    Bhargava, Rahul
    Arora, Yogesh C.
    Kaushal, Sidharth
    Kumar, Manjushri
    JOURNAL OF CYTOLOGY, 2015, 32 (04) : 261 - 267
  • [47] Association between dryness sensation and ocular surface temperature and conjunctival blood flow in soft contact lens wearers
    Itokawa, Takashi
    Okajima, Yukinobu
    Iwashita, Hiroko
    Koji, Kakisu
    Tashiro, Shigeki
    Suzuki, Takashi
    Hori, Yuichi
    CONTACT LENS & ANTERIOR EYE, 2024, 47 (03):
  • [48] Objective Assessment of Squamous Metaplasia of Conjunctival Epithelial Cells as Associated With Soft Contact Lens Wear Versus Non-Lens Wearers
    Doughty, Michael J.
    CORNEA, 2014, 33 (10) : 1095 - 1102
  • [49] Association between conjunctival goblet cells and corneal resident dendritic cell density changes in new contact lens wearers
    Colorado, Luisa H.
    Pritchard, Nicola
    Alzahrani, Yahya
    Edwards, Katie
    Efron, Nathan
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2020, 103 (06) : 787 - 791
  • [50] Evaluation of lens transparency using Scheimpflug photography and slit lamp biomicroscopy in the CJ-12,918 cataract model in the albino rat
    Baltrukonis, DJ
    Doshna, CM
    Fortner, JH
    Render, JA
    Verdugo, ME
    Somps, CJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U171 - U171