Discrimination of Beers by Cyclic Voltammetry Using a Single Carbon Screen-Printed Electrode

被引:10
|
作者
Rosello, Adam [1 ]
Serrano, Nuria [1 ,2 ]
Diaz-Cruz, Jose Manuel [1 ,2 ]
Arino, Cristina [1 ,2 ]
机构
[1] Univ Barcelona, Dept Chem Engn & Analyt Chem, Marti & Franques 1-11, Barcelona 08028, Spain
[2] Univ Barcelona, Inst Recerca Aigua IdRA, Barcelona 08028, Spain
关键词
Beer discrimination; Cyclic voltammetry; Screen-printed carbon electrode; Partial least squares; Partial least squares discriminant analysis; Support vector machine discriminant analysis; Artificial neural networks; MULTIVARIATE CURVE RESOLUTION; SUPPORT VECTOR MACHINES; TONGUES; CLASSIFICATION; FOODSTUFF; CHEMOMETRICS; TRENDS; NOSES;
D O I
10.1002/elan.202060515
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, simple and costless methodology without sample pre-treatment is proposed for the discrimination of beers. It is based on cyclic voltammetry (CV) using commercial carbon screen-printed electrodes (SPCE) and includes a correction of the signals measured with different SPCE units. Data are submitted to partial least squares discriminant analysis (PLS-DA) and support vector machine discriminant analysis (SVM-DA), which allow a reasonable classification of the beers. Also, CV data from beers can be used to predict their alcoholic degree by partial least squares (PLS) and artificial neural networks (ANN). In general, non-linear methods provide better results than linear ones.
引用
收藏
页码:864 / 872
页数:9
相关论文
共 50 条
  • [21] Single-Drop Analysis of Epinephrine and Uric Acid on a Screen-Printed Carbon Electrode
    Majer, David
    Finsgar, Matjaz
    BIOSENSORS-BASEL, 2021, 11 (08):
  • [22] Pb(II) Determination in a Single Drop Using a Modified Screen-Printed Electrode
    Zurga, Nika
    Majer, David
    Finsgar, Matjaz
    CHEMOSENSORS, 2021, 9 (02) : 1 - 10
  • [23] A cross examination of electron transfer rate constants for carbon screen-printed electrodes using Electrochemical Impedance Spectroscopy and cyclic voltammetry
    Randviir, Edward P.
    ELECTROCHIMICA ACTA, 2018, 286 : 179 - 186
  • [24] Voltammetric behavior of mycotoxin zearalenone at a single walled carbon nanotube screen-printed electrode
    Radi, Abd-Elgawad
    Eissa, Alsayed
    Wahdan, Tarek
    ANALYTICAL METHODS, 2019, 11 (35) : 4494 - 4500
  • [25] Determination of Copper(II) Through Anodic Stripping Voltammetry in Tartrate Buffer Using an Antimony Film Screen-printed Carbon Electrode
    Bobrowski, Andrzej
    Maczuga, Mariola
    Krolicka, Agnieszka
    Konstanteli, Evangelia
    Sakellaropoulou, Chrysavgi
    Economou, Anastasios
    ANALYTICAL LETTERS, 2017, 50 (18) : 2920 - 2936
  • [26] Antibiotic susceptibility testing at a screen-printed carbon electrode array
    Mann, Thomas S.
    Mikkelsen, Susan R.
    ANALYTICAL CHEMISTRY, 2008, 80 (03) : 843 - 848
  • [27] The Effect of Repeated Activation on Screen-Printed Carbon Electrode Cards
    Churinsky, C.
    Grgicak, C.
    STUDENT POSTERS (GENERAL) - 225TH ECS MEETING, 2014, 61 (26): : 1 - 8
  • [28] Screen-printed carbon electrode for the electrochemical detection of conjugated bilirubin
    Resmi, P. E.
    Raveendran, Jeethu
    Suneesh, P. V.
    Ramanchandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    MATERIALS LETTERS, 2021, 304
  • [29] Determination of Pd(II) using an antimony film coated on a screen-printed electrode by adsorptive stripping voltammetry
    Perez-Rafols, Clara
    Trechera, Pedro
    Serrano, Nuria
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miguel
    TALANTA, 2017, 167 : 1 - 7
  • [30] Electrochemically Activated Screen-Printed Carbon Electrode for Determination of Ibuprofen
    Tyszczuk-Rotko, Katarzyna
    Kozak, Jedrzej
    Wezinska, Anna
    APPLIED SCIENCES-BASEL, 2021, 11 (21):