Influence of Ambient Humidity on PDIV and Endurance of Inverter-fed Motor Insulation

被引:0
|
作者
Wang, Peng [1 ]
Li, Peiyi [1 ]
Li, Ying [1 ]
Cavallini, Andrea [2 ]
Zhang, Qin [3 ]
Zhang, Jiawei [4 ]
机构
[1] Sichuan Univ, Chengdu, Peoples R China
[2] Univ Bologna, Bologna, Italy
[3] St Johns Univ, New York, NY USA
[4] Northeast Elect Power Univ, Jilin, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
inverter-fed motor; insulation systems; partial discharge; endurance; PWM;
D O I
10.1109/eic43217.2019.9046593
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
this work aims to report the influence of ambient humidity on partial discharge inception voltage (PDIV) and lifetime (endurance) of the insulation for inverter-fed motors. The PDIV on polyimide film and rotor bar insulated by NOMEX at sinusoidal voltages with 50 Hz frequency and the endurance tests of inverter-fed motor turn insulation under repetitive unipolar impulsive voltages with 10 ns rise time and 200 ns voltage on-time were performed at four relative humidity (RH), i.e. 40% 60%, 80% 95%, controlling the ambient temperature at 50 degrees C . Experimental results show that both the PDIV and endurance decrease significantly with increasing RH. Accordingly, the influence of ambient humidity on the test results should be carefully considered when performing PDIV and endurance tests on the insulation of low-voltage and high-voltage inverter-fed motors according to IEC standards.
引用
收藏
页码:201 / 204
页数:4
相关论文
共 50 条
  • [1] The Influence of SPWM Frequency on the Endurance of Inverter-fed Motor Insulation
    Wang, Peng
    Zhao, Ming
    Zhou, Qun
    Zhang, Jiawei
    2019 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2019, : 142 - 145
  • [2] The Influence of Overvoltage from Repetitive Impulsive Voltages on PDIV and PDEV of Inverter-fed Motor Insulation
    Li J.
    Wang P.
    Wu Q.
    Zhou W.
    Yang N.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (15): : 4541 - 4549
  • [3] Modeling Humidity Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors at Different Temperatures
    Naderiallaf, H.
    Ji, Y.
    Giangrande, P.
    Galea, M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (03) : 1573 - 1582
  • [4] The Design of Automatic Test System Used for PDIV Measurement of Inverter-fed Motor
    Wang, Kejing
    Meng, Guodong
    Dong, Chengye
    Zhang, Dujiao
    Gao, Chong
    Cheng, Yonghong
    2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, : 651 - 654
  • [5] Voltage Endurance Testing Stator insulation systems for inverter-fed machines
    Stranges, Meredith K. W.
    Stone, Greg C.
    Bogh, Dennis L.
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2009, 15 (06) : 12 - 18
  • [6] Influence of Repetitive Impulse Voltage Parameters on the Signal-to-noise Ratio of PDIV Test for Inverter-fed Motor
    Li P.
    Wang P.
    Ma S.
    Dong H.
    Gu Y.
    Zhou W.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (08): : 2981 - 2990
  • [7] Low voltage PWM inverter-fed motor insulation issues
    Melfi, MJ
    INDUSTRY APPLICATIONS SOCIETY 51ST ANNUAL PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE, 2004, : 137 - 142
  • [8] Partial discharge detection technology on inverter-fed motor insulation
    Wang, Peng
    Zhou, Kai
    Wu, Guangning
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (02): : 519 - 525
  • [9] The Measurement of Space Charge in Solid Insulation of Inverter-fed Motor
    Liu, Jun
    Wu, Guangning
    Zhou, Kai
    Thou, Lijun
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 47 - 47
  • [10] Influence of Cable Insulation Structure on Terminal Over-voltage of Inverter-fed Motor
    Zhu Yongzhan
    Liu Xuezhong
    Gao Chao
    Deng Xianbo
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 75 - 78