Semiautomatic determination of ferrous iron in iron ore using a flow-injection technique

被引:0
|
作者
Lin, SL [1 ]
Man, H
Shu, Z
机构
[1] China Univ Geosci, Dept Appl Chem, Wuhan 430074, Peoples R China
[2] China Univ Geosci, Anal & Testing Ctr, Wuhan 430074, Peoples R China
关键词
D O I
10.1002/(SICI)1098-2728(2000)12:2<86::AID-LRA7>3.0.CO;2-K
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A semiautomatic method for mineral-phase analysis for ferrous iron (FeCO3) using on-line leaching technique was developed. A flow-injection manifold is described, which makes on-line leaching of the powdered sample followed by color developing of Fe(II) with o-phenanthroline and its spectrophotometric determination possible. This method can produce meaningful results provided that the experimental conditions are kept at optimum values. The analysis time is greatly reduced by using flow injection techniques. Sample throughput was about 22 samples/hr with a method precision of 2.7% RSD, depending on the leaching time chosen and FeCO3 content in ores. Analytical data were in good agreement with recommended values for analysis of standard references materials. For each analysis, 20-30 mg of powdered sample was required. (C) 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:86-90, 2000.
引用
收藏
页码:86 / 90
页数:5
相关论文
共 50 条
  • [21] SIMULTANEOUS DETERMINATION OF IRON(II), IRON(III), AND TITANIUM(IV) BY FLOW-INJECTION ANALYSIS USING KINETIC SPECTROPHOTOMETRY WITH TIRON
    OGUMA, K
    KOZUKA, S
    KITADA, K
    KURODA, R
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 341 (09): : 545 - 549
  • [22] SIMULTANEOUS DETERMINATION OF IRON AND COPPER IN WATERS BY MULTILIGAND FLOW-INJECTION ANALYSIS
    KUBAN, V
    GLADILOVICH, DB
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1988, 53 (07) : 1461 - 1475
  • [23] Automation in flow-injection analysis:: Simultaneous determination of chloride and total iron
    Neira, JY
    Nóbrega, JA
    LABORATORY ROBOTICS AND AUTOMATION, 1999, 11 (05) : 260 - 265
  • [24] Determination of Iron in Tap and Waste Water Using Liquid–Liquid Extraction in a Flow-Injection System
    María Jesús Almendral
    Angel Alonso
    María José Porras
    Marco A. García
    Yolanda Curto
    Microchimica Acta, 2004, 147 : 117 - 123
  • [25] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF COPPER(II) USING THE IRON(III) - THIOSULFATE CATALYTIC REACTION
    KAWAKUBO, S
    KATSUMATA, T
    IWATSUKI, M
    FUKASAWA, T
    FUKASAWA, T
    ANALYST, 1988, 113 (12) : 1827 - 1830
  • [26] Flow-injection determination of iron(III) in soil by biamperometry using two independent redox couples
    Chen, JQ
    Gao, W
    Song, JF
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01) : 194 - 200
  • [27] SIMULTANEOUS DETERMINATION OF TOTAL IRON AND CHROMIUM(VI) IN WASTE-WATER USING A FLOW-INJECTION SYSTEM BASED ON THE SANDWICH TECHNIQUE
    ARAUJO, AN
    LIMA, JLFC
    RANGEL, AOSS
    ALONSO, J
    BARTROLI, J
    BARBER, R
    ANALYST, 1989, 114 (11) : 1465 - 1468
  • [28] USE OF ACETOHYDROXAMIC ACID IN THE DIRECT SPECTROPHOTOMETRIC DETERMINATION OF IRON(III) AND IRON(II) BY FLOW-INJECTION ANALYSIS
    SENIOR, AT
    GLENNON, JD
    ANALYTICA CHIMICA ACTA, 1987, 196 : 333 - 336
  • [29] DETERMINATION OF IRON(II) AND IRON(III) BY FLOW-INJECTION AND AMPEROMETRIC DETECTION WITH A GLASSY-CARBON ELECTRODE
    DIEKER, JW
    VANDERLINDEN, WE
    ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) : 267 - 274
  • [30] SANDWICH TECHNIQUES IN FLOW-INJECTION ANALYSIS .2. SIMULTANEOUS DETERMINATION OF IRON(II) AND TOTAL IRON
    ALONSO, J
    BARTROLI, J
    DELVALLE, M
    BARBER, R
    ANALYTICA CHIMICA ACTA, 1989, 219 (02) : 345 - 350