A technique for estimating the absolute gain of a photomultiplier tube

被引:5
|
作者
Takahashi, M. [1 ]
Inome, Y. [2 ]
Yoshii, S. [2 ]
Bamba, A. [3 ]
Gunji, S. [9 ]
Hadasch, D. [1 ]
Hayashida, M. [1 ]
Katagiri, H. [6 ]
Konno, Y. [7 ]
Kubo, H. [7 ]
Kushida, J. [8 ]
Nakajima, D. [1 ]
Nakamori, T. [9 ]
Nagayoshi, T. [10 ]
Nishijima, K. [8 ]
Nozaki, S. [7 ]
Mazin, D. [1 ]
Mashuda, S. [7 ]
Mirzoyan, R. [4 ]
Ohoka, H. [1 ]
Orito, R. [5 ]
Saito, T. [1 ]
Sakurai, S. [1 ]
Takeda, J. [10 ]
Teshima, M. [1 ]
Terada, Y. [10 ]
Tokanai, F. [9 ]
Yamamoto, T. [1 ,2 ,5 ]
Yoshida, T. [6 ]
机构
[1] Univ Tokyo, Inst Cosm Ray Res, Kashiwa, Chiba 2778582, Japan
[2] Konan Univ, Fac Sci & Engn, Kobe, Hyogo 6588501, Japan
[3] Univ Tokyo, Dept Phys, Bunkyo Ku, Tokyo 1130033, Japan
[4] Max Planck Inst Phys & Astrophys, D-80805 Munich, Germany
[5] Tokushima Univ, Inst Socio Arts & Sci, Tokushima 7708502, Japan
[6] Ibaraki Univ, Coll Sci, Mito, Ibaraki 3108512, Japan
[7] Kyoto Univ, Dept Phys, Kyoto 6068502, Japan
[8] Tokai Univ, Dept Phys, Hiratsuka, Kanagawa 2591292, Japan
[9] Yamagata Univ, Dept Phys, Yamagata 9908560, Japan
[10] Saitama Univ, Dept Phys, Saitama 3388570, Japan
关键词
Photomultiplier; PMT; Photoelectron; Photon detector;
D O I
10.1016/j.nima.2018.03.034
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Detection of low-intensity light relies on the conversion of photons to photoelectrons, which are then multiplied and detected as an electrical signal. To measure the actual intensity of the light, one must know the factor by which the photoelectrons have been multiplied. To obtain this amplification factor, we have developed a procedure for estimating precisely the signal caused by a single photoelectron. The method utilizes the fact that the photoelectrons conform to a Poisson distribution. The average signal produced by a single photoelectron can then be estimated from the number of noise events, without requiring analysis of the distribution of the signal produced by a single photoelectron. The signal produced by one or more photoelectrons can be estimated experimentally without any assumptions. This technique, and an example of the analysis of a signal from a photomultiplier tube, are described in this study.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [41] An analytical model for photomultiplier tube calibration
    Kalousis, Leonidas N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1058
  • [42] DEVELOPMENT OF MULTIANODE PHOTOMULTIPLIER TUBE.
    Takasaki, Fumuhiko
    Saito, Hitoshi
    Fukui, Tohru
    Matsushita, Teruhiko
    Suzuki, Toshihiro
    Nuclear instruments and methods in physics research, 1987, A260 (2-3): : 447 - 450
  • [43] AN ANTI-CHERENKOV PHOTOMULTIPLIER TUBE
    SELOVE, W
    CORMELL, LR
    DRIS, M
    KONONENKO, W
    ROBINSON, B
    YOST, BT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 203 (1-3): : 615 - 616
  • [44] Calibration and characterization of the IceCube photomultiplier tube
    Abbasi, R.
    Abdou, Y.
    Abu-Zayyad, T.
    Adams, J.
    Aguilar, J. A.
    Ahlers, M.
    Andeen, K.
    Auffenberg, J.
    Bai, X.
    Baker, M.
    Barwick, S. W.
    Bay, R.
    Alba, J. L. Bazo
    Beattie, K.
    Beatty, J. J.
    Bechet, S.
    Becker, J. K.
    Becker, K. -H.
    Benabderrahmane, M. L.
    Berdermann, J.
    Berghaus, P.
    Berley, D.
    Bernardini, E.
    Bertrand, D.
    Besson, D. Z.
    Bissok, M.
    Blaufuss, E.
    Boersma, D. J.
    Bohm, C.
    Botner, O.
    Bradley, L.
    Braun, J.
    Buitink, S.
    Carson, M.
    Chirkin, D.
    Christy, B.
    Clem, J.
    Cohen, S.
    Colnard, C.
    Cowen, D. F.
    D'Agostino, M. V.
    Danninger, M.
    De Clercq, C.
    Demiroers, L.
    Depaepe, O.
    Descamps, F.
    Desiati, P.
    de Vries-Uiterweerd, G.
    DeYoung, T.
    Diaz-Velez, J. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 618 (1-3): : 139 - 152
  • [45] Photomultiplier tube of new dynode configuration
    Kyushima, H.
    Hasegawa, Y.
    Atsumi, A.
    Nagura, K.
    Yokota, H.
    Ito, M.
    Takeuchi, J.
    Oba, K.
    Matsuura, H.
    Suzuki, S.
    IEEE Transactions on Nuclear Science, 1994, 41 (4 pt 1): : 725 - 729
  • [46] An Improved Photomultiplier Tube Color Densitometer
    Sweet, Monroe H.
    JOURNAL OF THE SOCIETY OF MOTION PICTURE & TELEVISION ENGINEERS, 1950, 54 (01): : 35 - 62
  • [47] How to pick the proper photomultiplier tube
    Zankowsky, D
    LASER FOCUS WORLD, 1996, 32 (09): : 159 - +
  • [48] ABSOLUTE BYPHOTON METER OF PHOTOMULTIPLIER QUANTUM EFFICIENCY
    GINSBURG, VM
    KERATISHVILI, NG
    KORZHEVNEVICH, YL
    LUNEV, GV
    SAPRITSKY, VI
    RADIOTEKHNIKA I ELEKTRONIKA, 1992, 37 (07): : 1336 - 1338
  • [49] Comparison of pulsed-excitation and phase-modulation methods for estimating fluorescence lifetime values using a convolved-autoregressive model and a high-gain photomultiplier tube
    Iwata, Tetsuo
    Kiyoto, Hiroshige
    Mizutani, Yasuhiro
    Araki, Tsutomu
    OPTICAL REVIEW, 2010, 17 (06) : 513 - 518
  • [50] THE DETERMINATION OF PHOTOMULTIPLIER TEMPERATURE COEFFICIENTS FOR GAIN AND SPECTRAL SENSITIVITY USING THE PHOTON-COUNTING TECHNIQUE
    SINGH, AS
    WRIGHT, AG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 434 - 437