Use of mean platelet component to measure platelet activation on the ADVIA 120 haematology system

被引:0
|
作者
Macey, MG [1 ]
Carty, E
Webb, L
Chapman, ES
Zelmanovic, D
Okrongly, D
Rampton, DS
Newland, AC
机构
[1] Royal London Hosp, Dept Haematol, London E1 1BB, England
[2] Royal London Hosp, Dept Gastroenterol, London E1 1BB, England
[3] Bayer Diagnost, Div Diagnost, New York, NY USA
来源
CYTOMETRY | 1999年 / 38卷 / 05期
关键词
mean platelet component; platelet activation; ADVIA; 120; system;
D O I
10.1002/(SICI)1097-0320(19991015)38:5<250::AID-CYTO8>3.0.CO;2-K
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Platelet activation results in changes in a number of cell surface molecules including an increase in P-Selectin (CD62P) that may be rapidly and conveniently measured by immunofluorescent flow cytometry. The ADVIA 120 (Bayer) is a new system that facilitates more accurate measurement of platelet volume and in addition provides an approximate measure of the mean refractive index (RI) of the platelets reported as mean platelet component (MPC) concentration. We were interested to determine whether changes in MPC might reflect changes in platelet activation status. To investigate this, the platelet CD62P expression, determined by flow cytometry, and change in MPC, measured an the ADVIA 120 system, was first examined in vitro after stimulation of EDTA anticoagulated whole blood with submaximal concentrations of bovine thrombin in the presence or absence of the thromboxane synthase inhibitor, Ridogrel. Thrombin produced a dose-dependent increase in platelet CD62P expression and a decrease in MPC that could be inhibited by Ridogrel at physiological concentrations. In the second set of experiments, blood from 20 normal controls was collected into both EDTA and sodium citrate (SC) anticoagulants. Within 30 min of venesection and again at 3 h post-venesection after storage at room temperature, the platelet MPC and CD62P expression were determined. Platelets in all samples with both anticoagulants showed very low levels of CD62P expression when first analysed. At 3 h there was a small increase in CD62P expression on platelets in whole blood anticoagulated with SC, but a significant (P < 0.001) increase was observed on platelets anti-coagulated with EDTA. A negative correlation was found between the change in MPC of the platelets and the increase in the mean fluorescence intensity (MFI) (r = -0.69, P < 0.001, n = 20) and the percentage (r = -0.72, P < 0.001, n = 20) of CD62P positive platelets at 3 h in blood anticoagulated with EDTA. We conclude that a reduction in MPC as measured by the ADVIA 120 may be used to detect anticoagulant induced, as well as thrombin stimulated, in vitro platelet activation in blood anticoagulated with EDTA. Further, we conclude that platelet activation is negligible for up to 3 h in sodium citrate anticoagulated whole blood. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:250 / 255
页数:6
相关论文
共 50 条
  • [21] Mean platelet component and mean platelet volume as useful screening markers for myelodysplastic syndrome
    Masutani, Ryota
    Ikemoto, Toshiyuki
    Maki, Ayako
    Tanada, Hiroko
    Iwatani, Yoshinori
    Watanabe, Mikio
    Takubo, Takayuki
    Okada, Yoshikatsu
    HEALTH SCIENCE REPORTS, 2018, 1 (05)
  • [22] Mean platelet volume as an indicator of platelet activation: methodological issues
    Jagroop, IA
    Tsiara, S
    Mikhailidis, DP
    PLATELETS, 2003, 14 (05) : 335 - 336
  • [23] Mean platelet volume as an indicator of platelet activation: methodological issues
    Park, Y
    Schoene, N
    Harris, W
    PLATELETS, 2002, 13 (5-6) : 301 - 306
  • [24] Mean platelet volume as an indicator of platelet activation: Methodological issues
    Park, Y
    Schoene, N
    Harris, WS
    FASEB JOURNAL, 2002, 16 (04): : A240 - A240
  • [25] Platelet count and parameters determined by the Bayer ADVIA™ 120 in reference subjects and patients
    Giacomini, A
    Legovini, P
    Gessoni, G
    Antico, F
    Valverde, S
    Salvadego, MM
    Manoni, F
    CLINICAL AND LABORATORY HAEMATOLOGY, 2001, 23 (03): : 181 - 186
  • [26] Platelet counting by the Coulter LH 750, Sysmex XE 2100, and Advia 120
    Sandhaus, LM
    Osei, ES
    Agrawal, NN
    Dillman, CA
    Meyerson, HJ
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2002, 118 (02) : 235 - 241
  • [27] Changes of platelet parameters determined by the Bayer ADVIA™ 120 with EDTA sample age
    Song, KS
    Song, JW
    PLATELETS, 2005, 16 (3-4) : 223 - 224
  • [28] Preanalytical treatment of EDTA-anticoagulated blood to ensure stabilization of the mean platelet volume and component measured with the ADVIA counters
    Diaz-Ricart, Maribel
    Brunso, Lucas
    Pino, Marc
    Navalon, Fulgencio
    Jou, Josep M.
    Heras, Magda
    White, James G.
    Escolar, Gines
    THROMBOSIS RESEARCH, 2010, 126 (01) : E30 - E35
  • [29] THE USE OF MEAN PLATELET VOLUME FOR EVALUATION OF QUALITY OF PLATELET CONCENTRATES
    BROZOVIC, B
    SEGHATCHIAN, MJ
    MCSHINE, RL
    BLOOD COAGULATION & FIBRINOLYSIS, 1992, 3 (05) : 629 - 631
  • [30] USE OF MEAN PLATELET VOLUME IMPROVES DETECTION OF PLATELET DISORDERS
    BESSMAN, JD
    GILMER, PR
    GARDNER, FH
    BLOOD CELLS, 1985, 11 (01): : 127 - 135