Design and test of an ultrasonic experimental set-up for controlled delivery of encapsulated chemotherapy

被引:2
|
作者
Lafon, C. [1 ]
Somaglino, L. [1 ]
Bouchoux, G. [1 ]
Chesnais, S. [1 ]
Mestas, J. -L. [1 ]
Matias, A. [1 ]
Chapelon, J. Y. [1 ]
机构
[1] Univ Lyon, INSERM, U556, F-69424 Lyon 03, France
关键词
Ultrasound; Drug delivery; Liposomes; Inertial cavitation; In vivo; FOCUSED ULTRASOUND;
D O I
10.1016/j.irbm.2009.05.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Applying ultrasound on drug-loaded sonosensitive liposomes offers new possibilities for treating cancer. In vitro experiments were performed in the present study to define an index of inertial cavitation which could be used to monitor the delivery of drugs. This index could also be used to assess the sonosensitivity of new formulations of liposomes. Experiments were then carried out in rats bearing subcutaneous abdominal tumors. Based on pharmacokinetic and biodistribution studies, a period of 48 hours was chosen between the injection of the liposomes and the exposure to ultrasound. At the injected doses, liposomes slowed down significantly the tumor development. Ultrasound combined with liposomes seemed to contribute to the tumor control. However, the important efficacy of liposomes alone and the eventual weak interactions with ultrasound prevent to guarantee that the effect of ultrasound is significant. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:171 / 173
页数:3
相关论文
共 50 条
  • [41] Analysis of the Influence of the Experimental Set-up on the Settlement Observed in a Pile Load Test.
    Dente, Giovanni
    Rivista Italiana di Geotecnica, 1980, 14 (04): : 286 - 298
  • [42] Development of a Test Set-up for the Experimental Investigation of Dross Build-up in Liquid Zinc Baths
    Gerold, Eva
    Antrekowitsch, Helmut
    Reiss, Georg
    EBl, Werner
    World of Metallurgy - ERZMETALL, 2023, 76 (02): : 118 - 123
  • [43] Experimental set-up and data processing of the radial strip-drawing friction test
    Sniekers, RJJM
    Smits, HAA
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 1997, 66 (1-3) : 216 - 223
  • [44] Experimental set-up and data processing of the radial strip-drawing friction test
    Eindhoven Univ of Technology, Eindhoven, Netherlands
    J Mater Process Technol, 1-3 (216-223):
  • [45] Measurement set-up for determining ultrasonic velocity in porous rocks
    Visser, R.
    Heller, H.K.J.
    van Baaren, J.P.
    Delft progress report, 1988, 13 (1-2): : 179 - 188
  • [47] Design Model for the Drive and Actuator of the Test Set-Up of a Novel Flexible Robotic System
    Rauniyar, Aditya
    Roy, Debanik
    Pandit, Pankaj
    Atpadkar, Viinod
    2018 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMPUTING RESEARCH (IEEE ICCIC 2018), 2018, : 15 - 21
  • [48] A new test set-up for skull fracture characterisation
    Verschueren, P.
    Delye, H.
    Depreitere, B.
    Van Lierde, C.
    Haex, B.
    Berckmans, D.
    Verpoest, I.
    Goffin, J.
    Sloten, J. Vander
    Van der Perre, G.
    JOURNAL OF BIOMECHANICS, 2007, 40 (15) : 3389 - 3396
  • [49] Design of fin-propeller test set-up and analysis of roll stabilization ability
    Xia-fu Peng
    Fu-yi Li
    Gui-yun Ye
    Journal of Marine Science and Application, 2002, 1 (1) : 73 - 76
  • [50] CRYOGENIC VIBRATION TEST SET-UP FOR SPACE QUALIFICATION
    WILDEMAN, KJ
    PLOEGER, GR
    CRYOGENICS, 1989, 29 (05) : 559 - 562