Prototype energy models for data centers

被引:33
|
作者
Sun, Kaiyu [1 ]
Luo, Na [1 ]
Luo, Xuan [1 ]
Hong, Tianzhen [1 ]
机构
[1] Lawrence Berkeley Natl Lab, Bldg Technol & Urban Syst Div, One Cyclotron Rd, Berkeley, CA 94720 USA
关键词
Data center; EnergyPlus; Energy efficiency; Prototype energy model; Approach temperature; OpenStudio; AIR-DISTRIBUTION SYSTEMS; BUILDING ENERGY; PERFORMANCE; SIMULATION; DENSITY; FLOW; MANAGEMENT;
D O I
10.1016/j.enbuild.2020.110603
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Data centers in the United States consume about two percent of the nation's electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy's Commercial Prototype Building Models. This study presented the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft(2) (430 and 1076 W/m(2)) for the computer room, and 100 and 500 W/ft(2) (1076 and 5382 W/m(2)) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Energy Efficient HPC Data Centers
    Tschudi, Bill
    Martinez, David
    2012 SC COMPANION: HIGH PERFORMANCE COMPUTING, NETWORKING, STORAGE AND ANALYSIS (SCC), 2012, : 848 - 897
  • [22] Energy efficiency in data centers [1]
    Gonzalez, Roberto
    ASHRAE Journal, 2008, 50 (02)
  • [23] A Call for Energy Efficiency in Data Centers
    Pawlish, Michael
    Varde, Aparna S.
    Robila, Stefan A.
    Ranganathan, Anand
    SIGMOD RECORD, 2014, 43 (01) : 45 - 51
  • [24] Energy-Efficient Data Centers
    Stein, Jeff
    Bean, John
    Dunlap, Kevin
    ASHRAE JOURNAL, 2009, 51 (01) : 12 - +
  • [25] Data centers and energy balance in Finland
    Malkamaki, Tuomo
    Ovaska, Seppo J.
    2012 INTERNATIONAL GREEN COMPUTING CONFERENCE (IGCC), 2012,
  • [26] Energy-efficient data centers
    Shuja, Junaid
    Madani, Sajjad A.
    Bilal, Kashif
    Hayat, Khizar
    Khan, Samee U.
    Sarwar, Shahzad
    COMPUTING, 2012, 94 (12) : 973 - 994
  • [27] ENERGY STANDARD FOR DATA CENTERS 90.4
    Rodgers, Terry L.
    McFarlane, Robert E.
    Prisco, Joseph F.
    ASHRAE Journal, 2023, 65 (02): : 44 - 52
  • [28] Energy-Efficient Data Centers
    Shi, Weisong
    Wenisch, Thomas F.
    IEEE INTERNET COMPUTING, 2017, 21 (04) : 6 - 7
  • [29] Review of energy management for data centers in energy internet
    Feng C.
    Wang Y.
    Chen Q.
    Zhang X.
    Luo G.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (07): : 1 - 9
  • [30] ENERGY MODELS OF CENTERS CONTAINING OXYGEN IN GAAS
    MALINAUSKAS, RA
    PERVOVA, LY
    FISTUL, VI
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1982, 16 (03): : 296 - 298