Progress in the applicability of plasma X-ray lasers

被引:0
|
作者
Kuehl, T. [1 ,2 ]
Aurand, B. [1 ,2 ,6 ]
Bagnoud, V. [1 ]
Ecker, B. [1 ,2 ,5 ]
Eisenbarth, U. [1 ]
Guilbaud, O. [3 ]
Fils, J. [1 ]
Goette, S. [1 ]
Habib, J. [3 ]
Hochhaus, D. [1 ,6 ,7 ]
Javorkova, D. [1 ]
Neumayer, P. [6 ,7 ]
Kazamias, S. [3 ]
Pittman, M. [3 ]
Ros, D. [3 ]
Seres, J. [4 ]
Spielmann, Ch. [4 ]
Zielbauer, B. [1 ,5 ]
Zimmer, D. [1 ,2 ,3 ]
机构
[1] GSI Darmstadt, Darmstadt, Germany
[2] Johannes Gutenberg Univ Mainz, Mainz, Germany
[3] Univ Paris Sud, Orsay, France
[4] Friedrich Schiller Univ, Jena, Germany
[5] Helmholtz Inst, Jena, Germany
[6] Extreme Matter Inst, EMMI, Darmstadt, Germany
[7] Johann Wofgang von Goethe Univ, Frankfurt, Germany
关键词
X-ray lasers; Laser spectroscopy; Nuclear charge distribution; INCIDENCE PUMPING GEOMETRY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Proposed as satellite-based weapons during the 1980s, X-ray lasing was for a long time only achieved with enormous amounts of pump energy in either nuclear explosions or at kilojoule-class laser installations. During the last few years a tremendous development was achieved, most visible in the realisation of the FEL lasers at DESY and SLAC. As important for a wider applicability is the enormous reduction in pump energy for laser pumped plasma X-ray lasers, which now brings such devices into the range of applications for diagnostics and spectroscopy even in smaller laboratories. Main developments were the transient excitation scheme and the optimized pumping concepts. This paper concentrates on developments at the GSI Helmholtzcenter at Darmstadt aiming towards reliable X-ray laser sources in the range from 50 to several 100 eV. The main driving forces for the laser development at GSI are the possible application for the spectroscopy of Li-like ions in the storage ring ESR and the future storage ring NESR at FAIR, and the interest in novel plasma diagnostics.
引用
收藏
页码:233 / 241
页数:9
相关论文
共 50 条
  • [31] Hot and dense plasma probing by soft X-ray lasers
    Krus, M.
    Kozlova, M.
    Nejdl, J.
    Rus, B.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [32] X-ray lasers as probes to measure plasma ablation rates
    Tallents, G. J.
    Edwards, M. H.
    Whittaker, D. S.
    Mistry, P.
    Pert, G. J.
    Rus, B.
    Mocek, T.
    Kozlová, M.
    Polan, J.
    Praeg, A.
    Stupka, M.
    Homer, P.
    SOFT X-RAY LASERS AND APPLICATIONS VII, 2007, 6702
  • [33] Hydrodynamics perspective on OFI-plasma X-ray lasers
    Janulewicz, KA
    Healy, SB
    Pert, GJ
    X-RAY LASERS 1996, 1996, (151): : 156 - 160
  • [34] Plasma dynamics in capillary discharge soft x-ray lasers
    Ben-Kish, A
    Shuker, M
    Nemirovsky, RA
    Fisher, A
    Ron, A
    Schwob, JL
    PHYSICAL REVIEW LETTERS, 2001, 87 (01) : 1 - 015002
  • [35] Researchers: Smooth plasma would improve x-ray lasers
    Tatterson, KG
    PHOTONICS SPECTRA, 1996, 30 (11) : 32 - +
  • [36] BEAM OPTICS OF EXPLODING FOIL PLASMA X-RAY LASERS
    LONDON, RA
    PHYSICS OF FLUIDS, 1988, 31 (01) : 184 - 192
  • [37] Z-SCALING OF GAIN IN PLASMA X-RAY LASERS
    APRUZESE, JP
    DAVIS, J
    KEPPLE, PC
    BLAHA, M
    JOURNAL DE PHYSIQUE, 1986, 47 (C-6): : 15 - 22
  • [38] Similarity of plasma conditions of some Ne-like X-ray lasers and their partner Ni-like X-ray lasers
    Yan, F
    Zhang, J
    Lu, X
    Zhong, JY
    APPLIED PHYSICS B-LASERS AND OPTICS, 2004, 79 (02): : 229 - 233
  • [39] Similarity of plasma conditions of some Ne-like X-ray lasers and their partner Ni-like X-ray lasers
    F. Yan
    J. Zhang
    X. Lu
    J.Y. Zhong
    Applied Physics B, 2004, 79 : 229 - 233
  • [40] PROBLEMS IN THE IMPLEMENTATION OF X-RAY OPTICS WITH X-RAY LASERS
    MACGOWAN, BJ
    MROWKA, S
    BARBEE, TW
    DASILVA, LB
    EDER, DC
    KOCH, JA
    UNDERWOOD, JH
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (125): : 269 - 274