The impact of pump speed and inlet cannulation site on left ventricular unloading with a rotary blood pump

被引:11
|
作者
Vandenberghe, S
Nishida, T
Segers, P
Meyns, B
Verdonck, P
机构
[1] State Univ Ghent, Inst Biomed Technol, Hydraul Lab, B-9000 Ghent, Belgium
[2] Katholieke Univ Leuven, Ctr Expt Surg & Anesthesiol, Louvain, Belgium
关键词
cannulation; ventricular assist; rotary blood pump; energetic parameters; wall stress;
D O I
10.1111/j.1525-1594.2004.07374.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Ventricular assist devices are gaining ground in the therapeutic treatment of chronic heart failure. These devices are sometimes used as a bridge to recovery by unloading the left ventricle (LV) and restoring its function. It is therefore important to preserve the heart muscle and apply less invasive implantation methods. Methods: In this study ventricular unloading was achieved in 7 healthy sheep with a rotary blood pump at different pump flow levels. Ventricular cannulation via the left atrium (LA) and through the mitral valve was compared to atrial cannulation. The unloading of the heart was assessed with LV pressure-volume loops, derived energetic parameters, and an estimate of LV wall stress. Results: No significant difference between the cannulations was found for any flow or pressure. LA cannulation, however, resulted in significantly lower stroke volumes and stroke work for all pump flow levels. Irrespective of cannulation site, LV volumes and energetic parameters showed a significant decrease with increasing pump flow. Conclusion: LV assist with a rotary blood pump can provide sufficient unloading with atrial cannulation.
引用
收藏
页码:660 / 667
页数:8
相关论文
共 50 条
  • [1] Asymmetric speed modulation of a rotary blood pump affects ventricular unloading
    Pirbodaghi, Tohid
    Weber, Alberto
    Axiak, Shannon
    Carrel, Thierry
    Vandenberghe, Stijn
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (02) : 383 - 388
  • [2] Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation
    Gregory, Shaun D.
    Stevens, Michael C.
    Wu, Eric L.
    Pauls, Jo P.
    Kleinheyer, Matthias
    Fraser, John F.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (09) : 2674 - 2682
  • [3] Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation
    Shaun D. Gregory
    Michael C. Stevens
    Eric L. Wu
    Jo P. Pauls
    Matthias Kleinheyer
    John F. Fraser
    [J]. Annals of Biomedical Engineering, 2016, 44 : 2674 - 2682
  • [4] Echocardiographic markers of left ventricular unloading using a centrifugal-flow rotary pump
    Sauer, Andrew J.
    Meehan, Karen
    Gordon, Robert
    Abicht, Travis
    Rich, Jonathan D.
    Anderson, Allen S.
    Yancy, Clyde
    McGee, Edwin C., Jr.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : 449 - 450
  • [5] Haemodynamic Effect of Left Atrial and Left Ventricular Cannulation with a Rapid Speed Modulated Rotary Blood Pump During Rest and Exercise: Investigation in a Numerical Cardiorespiratory Model
    Wu, Eric L.
    Fresiello, Libera
    Kleinhyer, Matthias
    Meyns, Bart
    Fraser, John F.
    Tansley, Geoff
    Gregory, Shaun D.
    [J]. CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2020, 11 (04) : 350 - 361
  • [6] Haemodynamic Effect of Left Atrial and Left Ventricular Cannulation with a Rapid Speed Modulated Rotary Blood Pump During Rest and Exercise: Investigation in a Numerical Cardiorespiratory Model
    Eric L. Wu
    Libera Fresiello
    Matthias Kleinhyer
    Bart Meyns
    John F. Fraser
    Geoff Tansley
    Shaun D. Gregory
    [J]. Cardiovascular Engineering and Technology, 2020, 11 : 350 - 361
  • [7] Control Method of a Rotary Blood Pump for a Left Ventricular Assist Device
    Petukhov, D. S.
    Telyshev, D. V.
    Selishchev, S. V.
    [J]. SOVREMENNYE TEHNOLOGII V MEDICINE, 2016, 8 (01) : 28 - 33
  • [8] Rotary Blood Pump Control Strategy for Preventing Left Ventricular Suction
    Wang, Yu
    Koenig, Steven C.
    Slaughter, Mark S.
    Giridharan, Guruprasad A.
    [J]. ASAIO JOURNAL, 2015, 61 (01) : 21 - 30
  • [9] Feedback Control of Rotary Blood Pump for Preventing Left Ventricular Suction
    Son, Jeongeun
    Du, Dongping
    Du, Yuncheng
    [J]. 2019 AMERICAN CONTROL CONFERENCE (ACC), 2019, : 5426 - 5431
  • [10] Impact of the Rotational Pump Speed of the Implantable Left Ventricular Assist Device on Right Ventricular Pump Function
    Sakamoto, Takafumi
    Fujino, Takeo
    Higo, Taiki
    Ide, Tomomi
    Tanoue, Yoshihisa
    Shiose, Akira
    Tsutsui, Hiroyuki
    [J]. JOURNAL OF CARDIAC FAILURE, 2016, 22 (09) : S164 - S164