Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation

被引:6
|
作者
Gregory, Shaun D. [1 ,2 ]
Stevens, Michael C. [2 ,3 ]
Wu, Eric L. [1 ,2 ]
Pauls, Jo P. [2 ,4 ]
Kleinheyer, Matthias [2 ,4 ]
Fraser, John F. [1 ,2 ]
机构
[1] Univ Queensland, Sch Med, Brisbane, Qld, Australia
[2] Prince Charles Hosp, Innovat Cardiovasc Engn & Technol Lab, Crit Care Res Grp, Brisbane, Qld, Australia
[3] Univ New South Wales, Grad Sch Biomed Engn, Sydney, NSW, Australia
[4] Griffith Univ, Sch Engn, Southport, Qld, Australia
基金
英国医学研究理事会;
关键词
Ventricular assist device; Mitral valve regurgitation; Speed modulation; Cannula; Heart failure; MOCK CIRCULATION LOOP; BLOOD PUMPS; TRICUSPID REGURGITATION; AORTIC-INSUFFICIENCY; IMPLANTATION; PULSATILE; HEART; SIMULATION; FEATURES; MODE;
D O I
10.1007/s10439-016-1579-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mitral valve regurgitation (MVR) is common in patients receiving left ventricular assist device (LVAD) support, however the haemodynamic effect of MVR is not entirely clear. This study evaluated the haemodynamic effect of MVR with LVAD support and the influence of inflow cannulation site and LVAD speed modulation. Left atrial (LAC) and ventricular (LVC) cannulation was evaluated in a mock circulation loop with no, mild, moderate and severe MVR with constant speed and speed modulation (+/- 600 RPM) modes. The use of an LVAD relieved pulmonary congestion during severe MVR, by reducing left atrial pressure from 20.5 to 10.8 (LAC) and 11.5 (LVC) mmHg. However, LAC resulted in decreased left ventricular stroke work (-0.08 J), ejection fraction (-7.9%) and higher MVR volume (+ 12.7 mL) and pump speed (+ 100 RPM) compared to LVC. This suggests that LVC, in addition to reducing MVR severity, also improves ventricular washout over LAC. LVAD speed modulation in synchrony with ventricular systole reduced MVR volume and increased ejection fraction with LAC and LVC, thus demonstrating the potential benefits of this mode, despite a reduction in cardiac output.
引用
收藏
页码:2674 / 2682
页数:9
相关论文
共 50 条
  • [1] Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation
    Shaun D. Gregory
    Michael C. Stevens
    Eric L. Wu
    Jo P. Pauls
    Matthias Kleinheyer
    John F. Fraser
    [J]. Annals of Biomedical Engineering, 2016, 44 : 2674 - 2682
  • [2] The Effect of Concomitant Mitral Valve Procedures for Severe Mitral Valve Regurgitation During Left Ventricular Assist Device Implantation
    Kawabori, M.
    Kurihara, C.
    Critsinelis, A.
    Sugiura, T.
    Delgado, R. M.
    Simpson, L.
    Nair, A. P.
    Civitello, A. B.
    Rosengart, T. K.
    Frazier, O. H.
    Morgan, J. A.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S74 - S75
  • [3] Mitral valve repair for severe mitral valve regurgitation during left ventricular assist device implantation
    Pawale, Amit
    Itagaki, Shinobu
    Parikh, Aditya
    Pinney, Sean P.
    Adams, David H.
    Anyanwu, Anelechi C.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (05): : 1841 - +
  • [4] Effect of concomitant mitral valve procedures for severe mitral regurgitation during left ventricular assist device implantation
    Masashi Kawabori
    Chitaru Kurihara
    Ryan T. Conyer
    Andre C. Critsinelis
    Tadahisa Sugiura
    Todd Rosengart
    Jeffrey A. Morgan
    [J]. Journal of Artificial Organs, 2019, 22 : 91 - 97
  • [5] Effect of concomitant mitral valve procedures for severe mitral regurgitation during left ventricular assist device implantation
    Kawabori, Masashi
    Kurihara, Chitaru
    Conyer, Ryan T.
    Critsinelis, Andre C.
    Sugiura, Tadahisa
    Rosengart, Todd
    Morgan, Jeffrey A.
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2019, 22 (02) : 91 - 97
  • [6] Mitral valve repair for severe mitral valve regurgitation during left ventricular assist device implantation Discussion
    Silvestry, Scott
    Pawale
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (05): : 1848 - 1848
  • [7] The impact of pump speed and inlet cannulation site on left ventricular unloading with a rotary blood pump
    Vandenberghe, S
    Nishida, T
    Segers, P
    Meyns, B
    Verdonck, P
    [J]. ARTIFICIAL ORGANS, 2004, 28 (07) : 660 - 667
  • [8] Echocardiographic Outcomes Following Left Ventricular Assist Device or Mitral Valve Repair in Severe Left Ventricular Dilatation with Mitral Regurgitation
    Hungerford, S. L.
    Emmanuel
    Kearney, K.
    Jansz, P.
    Bart, N.
    Hayward, C.
    Mueller, D.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S332 - S332
  • [9] Resolution of Mitral Regurgitation With Left Ventricular Assist Device Support
    Goodwin, Matthew
    Nemeh, Hassan W.
    Borgi, Jamil
    Paone, Gaetano
    Morgan, Jeffrey A.
    [J]. ANNALS OF THORACIC SURGERY, 2017, 104 (03): : 811 - 819
  • [10] Change in Mitral Valve Geometry after Left Ventricular Assist Device Implantation in Patients with Functional Mitral Regurgitation
    Hayashi, H.
    Naka, Y.
    Sanchez, J.
    Takayama, H.
    Kurlansky, P.
    Ning, Y.
    Topkara, V.
    Yuzefpolskaya, M.
    Colombo, P. C.
    Sayer, G. T.
    Uriel, N.
    Takeda, K.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S405 - S406