Low-enthalpy geothermal systems for air conditioning: a case study in the Mediterranean climate

被引:2
|
作者
Frau, Caterina [1 ]
Maggio, Enrico [1 ]
Poggi, Francesca [1 ]
Melis, Emanuela [2 ]
Floris, Francesco [2 ]
Orru, Pier Francesco [2 ]
机构
[1] Sotacarbo SpA, I-09013 Grande Miniera Serbariu, Carbonia, Italy
[2] Univ Cagliari, Dept Mech Chem & Mat Engn, Via Marengo 2, I-09123 Cagliari, Italy
关键词
electric storage; low-enthalpy geothermal energy; photovoltaic system; heat pump; HEAT-EXCHANGERS; SIMULATION; MODEL;
D O I
10.1016/j.egypro.2018.08.129
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a preliminary evaluation of the technical and economic feasibility of a low-enthalpy geothermal system for air conditioning and its integration with other systems, including a photovoltaic plant and an electrical storage system. The pilot building is a research center located in the southern side of the Mediterranean basin (Sardinia, Italy). Preliminarily, the main geological, hydrogeological and geothermal characteristics of the area were analyzed. Then, an energetic assessment of the building and its plants was performed. The hourly production of a photovoltaic plant already designed for the building was assessed. To improve the energy efficiency and the thermal energy self-consumption, an alternative thermal generation plant was proposed to replace the existing air conditioning system: a water-water heat pump coupled with a low-enthalpy geothermal probe (vertical configuration), to be embedded into the ground or placed into an existing groundwater well. The feasibility of electric storage was evaluated by considering a system capacity of 100 kWh to temporarily store and self-consume the electricity overproduced by the photovoltaic plant. A preliminary economic assessment showed the viability of the photovoltaic system. The 100 kWh-capacity electric storage will increase the self-production percentage, but it is not economically affordable. The replacement of the current air-water heat pumps with one water-water heat pump will be economically convenient if coupled with a groundwater geothermal probe, but the solution of a vertical probe embedded into the ground is unsustainable, due to high drilling costs. (C) 2018 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:527 / 534
页数:8
相关论文
共 50 条
  • [41] Zeotropic mixtures as working fluids in Organic Rankine Cycles for low-enthalpy geothermal resources
    Heberle, Florian
    Preissinger, Markus
    Brueggemann, Dieter
    [J]. RENEWABLE ENERGY, 2012, 37 (01) : 364 - 370
  • [42] A data-driven approach to low-enthalpy shallow geothermal energy extraction: A case study on indoor heating for precision agriculture applications
    De Leon-Ruiz, J. E.
    Beltran-Chacon, R.
    Carvajal-Mariscal, I
    Zacarias, A.
    Rodriguez-Maese, R.
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2022, 40
  • [43] The Sealing Performance of Cement Sheaths under Thermal Cycles for Low-Enthalpy Geothermal Wells
    Corina, Anisa Noor
    Moghadam, Al
    [J]. ENERGIES, 2024, 17 (01)
  • [44] Deciphering origins and pathways of low-enthalpy geothermal waters in the unconventional geothermal system of Juchipila graben (Central Mexico)
    Billarent-Cedillo, Andrea
    Levresse, Gilles
    Ferrari, Luca
    Inguaggiato, Claudio
    Inguaggiato, Salvatore
    Hernandez-Perez, Eliseo
    Hernandez-Espriu, Antonio
    Corbo Camargo, Fernando
    Carrera Hernandez, Jaime
    Arias-Paz, Alberto
    [J]. GEOTHERMICS, 2021, 94
  • [45] Geometric arrangement and operation mode adjustment in low-enthalpy geothermal borehole fields for heating
    Beck, Markus
    Bayer, Peter
    de Paly, Michael
    Hecht-Mendez, Jozsef
    Zell, Andreas
    [J]. ENERGY, 2013, 49 : 434 - 443
  • [46] Performance analyses of a hybrid geothermal-fossil power generation system using low-enthalpy geothermal resources
    Liu, Qiang
    Shang, Linlin
    Duan, Yuanyuan
    [J]. APPLIED ENERGY, 2016, 162 : 149 - 162
  • [47] A prototype design model for deep low-enthalpy hydrothermal systems
    Saeid, Sanaz
    Al-Khoury, Rafid
    Nick, Hamidreza M.
    Hicks, Michael A.
    [J]. RENEWABLE ENERGY, 2015, 77 : 408 - 422
  • [48] Efficiency of a Compressor Heat Pump System in Different Cycle Designs: A Simulation Study for Low-Enthalpy Geothermal Resources
    Szymiczek, Jakub
    Szczotka, Krzysztof
    Banas, Marian
    Jura, Przemyslaw
    [J]. ENERGIES, 2022, 15 (15)
  • [49] Down-Hole Heat Exchangers: Modelling of a Low-Enthalpy Geothermal System for District Heating
    Carlini, M.
    Castellucci, S.
    Allegrini, E.
    Tucci, A.
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2012, 2012
  • [50] Fluid geochemistry in a low-enthalpy geothermal field along a sector of southern Apennines chain (Italy)
    Apollaro, C.
    Caracausi, A.
    Paternoster, M.
    Randazzo, P.
    Aiuppa, A.
    De Rosa, R.
    Fuoco, I
    Mongelli, G.
    Muto, F.
    Vanni, E.
    Vespasiano, G.
    [J]. JOURNAL OF GEOCHEMICAL EXPLORATION, 2020, 219