10.1016/j.ijcard.2005.07.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In patients with severe heart failure, sinus rhythm and wide QRS complex biventricular (BiV) pacing leads to clinical and haemodynamic improvement, but the immediate reversibility of these changes is not known. Methods: We assessed the acute and medium-term (3-month) haemodynamic effects of BiV pacing and of switching to other pacing modalities in 21 patients with severe heart failure, sinus rhythm and QRS >= 130 ins. Haemodynamic studies were performed: 1) at the time of implantation of a BiV pacing device, during AAI pacing, atrial synchronous right ventricular (RV) pacing, atrial synchronous left ventricular (LV) pacing and atrial synchronous BiV pacing (all at 100 bpm); 2) after 3 months of continuous BiV pacing-with evaluations being made by switching to RV and the other pacing modalities. Results: At both the acute and medium-term evaluations, BiV pacing provided the greatest improvement in cardiac index. Switching from BiV to RV pacing led to a more marked decrease in the cardiac index at 3 months. No strict correlation was evident between acute and medium-term effects of BiV pacing on cardiac index. Conclusion: Cardiac resynchronization by BiV pacing provides acute/medium-term improvements in cardiac index. Sudden, medium-term failure of LV stimulation can lead to an even more pronounced haemodynamic derangement than that inducible by RV pacing at baseline. Acute haemodynamic evaluations do not seem to provide a powerful way for identifying medium-term responders. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:318 / 323
页数:6
相关论文
共 50 条
  • [21] Acute Effects of Multisite Biventricular Pacing on Dyssynchrony and Hemodynamics in Canines With Heart Failure
    Qiu, Qiong
    Yang, Li
    Mai, Jing-Ting
    Yang, Ying
    Xie, Yong
    Chen, Yang-Xin
    Wang, Jing-Feng
    JOURNAL OF CARDIAC FAILURE, 2017, 23 (04) : 304 - 311
  • [22] Acute hemodynamic effects of biventricular DDD pacing in patients with end-stage heart failure
    Leclercq, C
    Cazeau, S
    Le Breton, H
    Ritter, P
    Mabo, P
    Gras, D
    Pavin, D
    Lazarus, A
    Daubert, JC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) : 1825 - 1831
  • [23] Acute Effects of Biventricular Pacing in Heart Failure Patients with a Normal Ejection Fraction and Mechanical Dyssynchrony
    Wang, Yi-Chih
    Yu, Chih-Chieh
    Chiu, Fu-Chun
    Splett, Vincent
    Klepfer, Ruth
    Hilpisch, Kathryn
    Tsai, Chia-Ti
    Lai, Ling-Ping
    Hwang, Juey-Jen
    Lin, Jiunn-Lee
    CARDIOLOGY, 2015, 130 (02) : 112 - 119
  • [24] Advances in biventricular pacing for heart failure
    Lau, CP
    CLINICAL AND OCCUPATIONAL MEDICINE: A HANDBOOK FOR OCCUPATIONAL PHYSICIANS, 2004, : 151 - 163
  • [25] Biventricular Pacing Therapy for Heart Failure
    Henry
    Chenk-Man Yu
    SouthChinaJournalofCardiology, 2001, (02) : 81 - 81
  • [26] Acute hemodynamic effects of biventricular and left ventricular pacing in chronic pacemaker-dependent patients with advanced heart failure
    Hansen, C
    Sperzel, J
    Neumann, T
    Pitschner, HF
    Neuzner, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 2003, 92 (10): : 862 - 868
  • [27] Conduction System Pacing vs Biventricular Pacing in Heart Failure and Wide QRS Patients
    Pujol-Lopez, Margarida
    Jimenez-Arjonad, Rafael
    Garre, Paz
    Guasch, Eduard
    Borras, Roger
    Doltra, Adelina
    Ferro, Elisenda
    Garcia-Ribas, Cora
    Niebla, Mireia
    Carro, Esther
    Puente, Jose L.
    Vazquez-Calvo, Sara
    Invers-Rubio, Eric
    Roca-Luque, Ivo
    Castel, M. Angeles
    Arbelo, Elena
    Sitges, Marta
    Brugada, Josep
    Tolosana, Jose M.
    Mont, Lluis
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (11) : 1431 - 1445
  • [28] Left ventricular pacing should be considered when biventricular pacing worsens heart failure: left ventricular pacing instead of biventricular pacing?
    Ahsan, Syed Y.
    Fittall, Matthew W.
    Gopalamurugan, Aerakondal B.
    McCready, James W.
    Nunn, Laurence
    Chow, Anthony W.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 33 (01) : 37 - 41
  • [29] Left ventricular pacing alone has acute benefits similar to those biventricular pacing in patients with severe heart failure
    Vinereanu, D
    Bleasdale, RA
    Turner, MS
    Frenneaux, MP
    Fraser, AG
    CIRCULATION, 2003, 108 (17) : 346 - 346
  • [30] Biventricular pacing reduces arrhythmic burden in heart failure patients
    Voigt, A
    Saba, S
    JOURNAL OF CARDIAC FAILURE, 2005, 11 (06) : S147 - S147