The gain G of SiPMs depends both on bias voltage and on temperature. For stable operation in large detector systems, gain needs to be kept constant. This can be achieved by readjusting the bias voltage with temperature. We have built an adaptive bias voltage regulator (ADApower) that uses a linear algorithm to adjust the bias voltage V if the temperature T changes. We determined the V(T) dependence from measurements of the gain-versus-temperature dependence (dG/dT) for different bias voltage and the gain-versus-bias voltage dependence (dG/dV) for different temperatures in a climate chamber Spiral3 at CERN. We tested and studied 30 pieces of SiPM in groups of six types in temperature range of 5 to 40 degrees C and found that the gain stabilization works excellently (<1%).
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Gain Stabilization of SiPMs
    Cvach, Jaroslav
    Eigen, Gerald
    Kvasnicka, Jiri
    Polak, Ivo
    Van der Kraaij, Erik
    Zalieckas, Justas
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] Gain Stabilization of SiPMs and Afterpulsing
    Eigen, Gerald
    18TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2018), 2019, 1162
  • [3] Gain stabilization of SiPMs with an adaptive power supply
    Eigen, G.
    Cvach, J.
    Kvasnicka, J.
    Polak, I
    Traeet, A.
    Zalieckas, J.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (05):
  • [4] Gain stabilization and noise minimization for SiPMs at cryogenic temperatures
    Achenbach, P.
    Biroth, M.
    Lauth, W.
    Thomas, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 110 - 111
  • [5] Is the gain-voltage dependence of SiPMs linear?
    Antonello, M.
    Brinkmann, L.
    Garutti, E.
    Klanner, R.
    Schwandt, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1076
  • [6] The design of a scintillation system based on SiPMs integrated with gain correction functionality
    Lin, Zhenhua
    Hautefeuille, Benoit
    Jung, Sung-Hee
    Moon, Jinho
    Park, Jang-Guen
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (01) : 164 - 169
  • [7] New Approach to Calibration of Low Gain PMTs and SiPMs Using Transit Time Histograms
    Vinogradov, Sergey
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [8] Gain Stabilization of Silicon Photomultipliers
    Cvach, J.
    Eigen, G.
    Kvasnicka, J.
    Polak, I.
    Traeet, A.
    Zalieckas, J.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [9] PRECISION PHOTOMULTIPLIER GAIN STABILIZATION
    HENDRICK, RW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1956, 27 (04): : 240 - 241
  • [10] STABILIZATION OF GAIN OF MEASURING AMPLIFIERS
    VAULIN, VE
    KRISILOV, YD
    MEASUREMENT TECHNIQUES-USSR, 1970, (08): : 1289 - &