Real-Time Soil CO2 Respiration Rate Determination and the Comparison between the Infrared Gas Analyzer and Microrespirometer (MicroRes®) Methods

被引:4
|
作者
Sparda, Andrew [1 ]
Miller, Robert O. [2 ]
Anderson, George [3 ]
Hsieh, Yuch-Ping [4 ]
机构
[1] Intuit Consulting Solut LLC, Readfield, ME USA
[2] Colorado State Univ, Collaborat Testing Serv Inc, Agr Lab Proficiency ALP Program, Ft Collins, CO 80523 USA
[3] R Squared Diagnost LLC, Indianapolis, IN USA
[4] Florida A&M Univ FAMU, Coll Agr & Food Sci, Ctr Water & Air Qual, Tallahassee, FL USA
关键词
Chemical titration; infrared gas analysis; microbial biomass; organic matter; respirometer; soil CO2 respiration; soil health; soil microbial activity; soil quality; soil testing; ORGANIC-MATTER; FOREST;
D O I
10.1080/00103624.2016.1254235
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Soil carbon dioxide (CO2) respiration is one of the important soil health parameters that provides a general assessment of soil microbial activity and soil quality. Soil respiration rates, however, have not been widely applied in soil testing protocols mainly because the traditional methods are either inconvenient, technically cumbersome or too expensive. Currently, only two methods are available for a true real-time soil respiration rate determination (<2h): the infrared gas analyzer (IRGA) and the microrespirometer (MR or MicroRes((R))) methods. We analyzed the real-time soil respiration rates of 20 soil samples from fifteen states after various periods of incubation using the IRGA method and the MR method. The measured soil respiration rates ranged from 0.4 mu L CO2/h/g to 9.0 mu L CO2/h/g. Both methods show precision in soil respiration determinations (CV=12.7% and 11.9%, respectively). Comparison of the results between the IRGA and MR methods indicates high degrees of agreement (r(2)=0.914). This study shows that the MR method is a simpler and more cost-effective alternative for real-time soil respiration rate determinations.
引用
收藏
页码:214 / 221
页数:8
相关论文
共 50 条
  • [21] Performance of Solid-State Sensors for Continuous, Real-Time Measurement of Soil CO2 Concentrations
    Young, Stephen L.
    Pierce, Francis J.
    Streubel, Jason D.
    Collins, Harold P.
    AGRONOMY JOURNAL, 2009, 101 (06) : 1417 - 1420
  • [22] Contribution of soil fauna respiration to CO2 flux in subtropical Moso bamboo (Phyllostachys pubescens) forests: a comparison of different soil treatment methods
    Yan Jiang
    Bing Wang
    Xiang Niu
    Zhixin Dong
    Peng Wang
    Environmental Earth Sciences, 2016, 75
  • [23] Contribution of soil fauna respiration to CO2 flux in subtropical Moso bamboo (Phyllostachys pubescens) forests: a comparison of different soil treatment methods
    Jiang, Yan
    Wang, Bing
    Niu, Xiang
    Dong, Zhixin
    Wang, Peng
    ENVIRONMENTAL EARTH SCIENCES, 2016, 75 (13)
  • [24] Improvement of the Real-Time Response Curve Estimation of the Canopy Net Photosynthetic Rate to the CO2 Supply Rate in a Ventilated Greenhouse
    Kawashima, Takashi
    Matsuda, Ryo
    Fujiwara, Kazuhiro
    HORTSCIENCE, 2019, 54 (09) : S293 - S293
  • [25] PERI- AND POSTOPERATIVE REAL-TIME MEASUREMENT OF MYOCARDIAL CO2 TENSION AND CO2 GENERATION RATE AS A PROMISING CLINICAL TOOL FOR DETECTION OF CARDIAC ISCHEMIA
    Pischke, Soeren
    Tronstad, Christian
    Tonnessen, Tor Inge
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A87 - A87
  • [26] DETERMINATION OF RATE CONSTANT OF GAS-PHASE REACTION BETWEEN O(1D) AND CO2
    CLERC, M
    REIFFSTECK, A
    JOURNAL OF CHEMICAL PHYSICS, 1968, 48 (06): : 2799 - +
  • [27] Real-Time In Situ Monitoring of CO2 Electroreduction in the Liquid and Gas Phases by Coupled Mass Spectrometry and Localized Electrochemistry
    Zhang, Guohui
    Cui, Youxin
    Kucernak, Anthony
    ACS CATALYSIS, 2022, 12 (10) : 6180 - 6190
  • [28] Optical parametric oscillator-based photoacoustic detection of CO2 at 4.23 μm allows real-time monitoring of the respiration of small insects
    M.M.J.W. van Herpen
    A.K.Y. Ngai
    S.E. Bisson
    J.H.P. Hackstein
    E.J. Woltering
    F.J.M. Harren
    Applied Physics B, 2006, 82 : 665 - 669
  • [29] Real-time monitoring of CO2 gas using inverse opal photonic gel containing Poly(2-(dimethylamino)ethylmethacrylate
    Heo, Nam Yeon
    Park, Shin Geun
    Kim, Donghoon
    Lee, Hyunjung
    Lee, Wonmok
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 377
  • [30] Optical parametric oscillator-based photoacoustic detection of CO2 at 4.23 μm allows real-time monitoring of the respiration of small insects
    van Herpen, MMJW
    Ngai, AKY
    Bisson, SE
    Hackstein, JHP
    Woltering, EJ
    Harren, FJM
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 82 (04): : 665 - 669