New data-reduction method in detector-based spectral-irradiance measurements

被引:3
|
作者
Andor, G
机构
关键词
D O I
10.1088/0026-1394/32/6/18
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Detector-based bandfilter radiometry has recently become increasingly popular in the fields of absolute spectral-irradiance measurements, black-body temperature determination and comparison with source-based measurements. This paper introduces an advanced data-reduction method which handles all bandfilter measurements together. An analytical function approximation is used on Planckian radiation multiplied by a polynomial emissivity.
引用
收藏
页码:495 / 496
页数:2
相关论文
共 50 条
  • [31] SOLAR CONSTANT BASED ON NEW SPECTRAL IRRADIANCE DATA FROM 3100 TO 5300 A
    STAIR, R
    WATERS, WR
    ELLIS, HT
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1967, 57 (04) : 575 - &
  • [32] Detector-based spectral CT with a novel dual-layer technology: principles and applications
    Rassouli, Negin
    Etesami, Maryam
    Dhanantwari, Amar
    Rajiah, Prabhakar
    INSIGHTS INTO IMAGING, 2017, 8 (06): : 589 - 598
  • [33] Detector-based spectral CT with a novel dual-layer technology: principles and applications
    Negin Rassouli
    Maryam Etesami
    Amar Dhanantwari
    Prabhakar Rajiah
    Insights into Imaging, 2017, 8 : 589 - 598
  • [34] Development of a detector-based absolute spectral power responsivity scale in the spectral range of 300-1600 nm
    Karmalawi, Abdallah M.
    Abdelmageed, Alaaeldin A.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2021, 32 (04) : 5215 - 5221
  • [35] Photo detector-based indoor positioning systems variants: A new look
    Khan, Muhammad Nasir
    Jamil, M.
    Gilani, S. O.
    Ahmad, I
    Uzair, Muhammad
    Omer, H.
    COMPUTERS & ELECTRICAL ENGINEERING, 2020, 83
  • [36] Simple data-reduction method for high-resolution LC-MS data in metabolomics
    Scheltema, R. A.
    Decuypere, S.
    Dujardin, J. C.
    Watson, D. G.
    Jansen, R. C.
    Breitling, R.
    BIOANALYSIS, 2009, 1 (09) : 1551 - 1557
  • [37] A new batch-processing data-reduction application for X-ray diffraction data
    Davies, RJ
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2006, 39 : 267 - 272
  • [38] OPTICAL POWER AND TRANSMITTANCE MEASUREMENTS AND THEIR USE IN DETECTOR-BASED REALIZATION OF THE LUMINOUS INTENSITY SCALE
    KARHA, P
    LASSILA, A
    LUDVIGSEN, H
    MANOOCHEHRI, F
    FAGERLUND, H
    IKONEN, E
    OPTICAL ENGINEERING, 1995, 34 (09) : 2611 - 2618
  • [39] Mixed Signal System Design Verification Accelerated With Detector-Based Diagnostic Method
    Dammers, D.
    Domingues, C.
    Schollaen, D.
    Vosskaemper, L. M.
    BMAS 2009: PROCEEDINGS OF THE 2009 IEEE INTERNATIONAL BEHAVIORAL MODELING AND SIMULATION WORKSHOP, 2009, : 66 - +
  • [40] Noise characteristics of virtual monoenergetic images from a novel detector-based spectral CT scanner
    Kalisz, Kevin
    Rassouli, Negin
    Dhanantwari, Amar
    Jordan, David
    Rajiah, Prabhakar
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 98 : 118 - 125