Loop-mediated isothermal amplification (LAMP) test in the detection of uncomplicated malaria in pregnancy: a meta-analysis of diagnostic accuracy

被引:2
|
作者
Yon, Joseph Lee Teck [1 ,2 ]
Htet, Norah Htet [1 ]
Naing, Cho [3 ]
Tung, Wong Siew [1 ]
Aung, Htar Htar [1 ]
Mak, Joon Wah [4 ]
机构
[1] Int Med Univ, Sch Med, Kuala Lumpur, Malaysia
[2] Univ Edinburgh, Old Coll, Edinburgh EH8 9YL, Scotland
[3] James Cook Univ, Div Trop Hlth & Med, Townsville, Qld, Australia
[4] Int Med Univ, Inst Res Dev & Innovat IRDI, Kuala Lumpur, Malaysia
关键词
PERFORMANCE; PCR;
D O I
10.1186/s12936-022-04419-9
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Due to relatively low malaria parasitaemia in pregnancy, an appropriate field test that can adequately detect infections in pregnant women presenting with illness or for malaria screening during antenatal care is crucially important. The objective was to evaluate the diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for the detection of uncomplicated malaria in pregnancy. Methods: This was a meta-analysis of diagnostic accuracy. Relevant studies that assessed the diagnostic performance of LAMP for the detection of malaria in pregnancy were searched in health-related electronic databases including PubMed, Ovid, and Google Scholar. The methodological quality of the studies included was evaluated using the QUADAS-2 tool.Results: Of the 372 studies identified, eight studies involving 2999 pregnant women in five endemic countries that assessed the accuracy of LAMP were identified. With three types of PCR as reference tests, the pooled sensitivity of LAMP was 91% (95%CI 67-98%) and pooled specificity was 99% (95%CI 83-100%, 4 studies), and the negative likelihood ratio was 9% (2-40%). Caution is needed in the interpretation as there was substantial between-study heterogeneity (I2: 80%), and a low probability that a person without infection is tested negative. With microscopy as a reference, the pooled sensitivity of LAMP was 95% (95%CI 26-100%) and pooled specificity was 100% (95%CI 94-100%, 4 studies). There was a wide range of sensitivity and substantial between-study heterogeneity (I2: 83.5-98.4%). To investigate the source of heterogeneity, a meta-regression analysis was performed with covariates. Of these potential confounding factors, reference test (p: 0.03) and study design (p:0.03) had affected the diagnostic accuracy of LAMP in malaria in pregnancy. Overall, there was a low certainty of the evidence in accuracy estimates.Conclusion: The findings suggest that LAMP is more sensitive than traditional tests used at facilities, but the utility of detecting and treating these low-density infections is not well understood. Due to the limited number of studies with bias in their methodological quality, variation in the study design, and different types of reference tests further research is likely to change the estimate. Well-conceived large prospective studies with blinding of the index test results are recommenced.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for detection of Leishmania DNA in buffy coat from visceral leishmaniasis patients
    Md Gulam Musawwir Khan
    Khondaker Rifat Hasan Bhaskar
    Md Abdus Salam
    Tania Akther
    Gerd Pluschke
    Dinesh Mondal
    Parasites & Vectors, 5 (1)
  • [42] Application of loop-mediated isothermal amplification (LAMP) for the detection of duck enteritis virus
    Wozniakowski, Grzegorz
    MEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICE, 2014, 70 (03): : 169 - 171
  • [43] Rapid detection of mecA and spa by the loop-mediated isothermal amplification (LAMP) method
    Koide, Y.
    Maeda, H.
    Yamabe, K.
    Naruishi, K.
    Yamamoto, T.
    Kokeguchi, S.
    Takashiba, S.
    LETTERS IN APPLIED MICROBIOLOGY, 2010, 50 (04) : 386 - 392
  • [44] Rapid and sensitive detection of Streptococcus iniae by loop-mediated isothermal amplification (LAMP)
    Han, H-J
    Jung, S-J
    Oh, M-J
    Kim, D-H
    JOURNAL OF FISH DISEASES, 2011, 34 (05) : 395 - 398
  • [45] Designing primers for loop-mediated isothermal amplification (LAMP) for detection of Ganoderma boninense
    Akul, Yushahfira
    Kumar, Vijay
    Chong, Khim Phin
    BULGARIAN JOURNAL OF AGRICULTURAL SCIENCE, 2018, 24 (05): : 854 - 859
  • [46] Rose rosette virus detection using loop-mediated isothermal amplification (LAMP)
    Salazar Aguirre, A.
    Molina Cardenas, S.
    Ochoa-Corona, F.
    Olson, J.
    PHYTOPATHOLOGY, 2016, 106 (12) : 117 - 117
  • [47] Development and application of loop-mediated isothermal amplification (LAMP) for detection of Plasmopara viticola
    Kong, Xiangjiu
    Qin, Wentao
    Huang, Xiaoqing
    Kong, Fanfang
    Schoen, Cor D.
    Feng, Jie
    Wang, Zhongyue
    Zhang, Hao
    SCIENTIFIC REPORTS, 2016, 6
  • [48] Development of loop-mediated isothermal amplification (LAMP) for simple detection of Leishmania infection
    Sriworarat, Chaichontat
    Phumee, Atchara
    Mungthin, Mathirut
    Leelayoova, Saovanee
    Siriyasatien, Padet
    PARASITES & VECTORS, 2015, 8
  • [49] Development of a loop-mediated isothermal amplification (LAMP) assay for the detection of Anaplasma marginale
    Giglioti, Rodrigo
    Bassetto, Cesar Cristiano
    Okino, Cintia Hiromi
    de Oliveira, Henrique Nunes
    de Sena Oliveira, Marcia Cristina
    EXPERIMENTAL AND APPLIED ACAROLOGY, 2019, 77 (01) : 65 - 72
  • [50] Development and application of loop-mediated isothermal amplification (LAMP) for detection of Plasmopara viticola
    Xiangjiu Kong
    Wentao Qin
    Xiaoqing Huang
    Fanfang Kong
    Cor D. Schoen
    Jie Feng
    Zhongyue Wang
    Hao Zhang
    Scientific Reports, 6