Microchip capillary electrophoresis with amperometric detection for several carbohydrates

被引:35
|
作者
Lee, HL [1 ]
Chen, SC [1 ]
机构
[1] Fu Jen Catholic Univ, Dept Chem, Taipei 242, Taiwan
关键词
carbohydrates; microchip; capillary electrophoresis; amperometric detection; copper electrode;
D O I
10.1016/j.talanta.2004.02.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microchip capillary electrophoresis (muCE) with amperometric detection at Cu electrode benefited fast separation and direct detection of carbohydrates. The working electrode of 50-mum Cu wire attached nearly against the channel outlet-4 mum, where it benefited collecting detection current and suppressing overwhelming noise. The use of alkaline medium was essential to separating and detecting carbohydrates, which dissociated into the sensitive alcolate anions. The 10-cm serpentine chip, though lengthening the migration time, it provided better efficiency. Sucrose, cellobiose, glucose, and fructose migrated from the outlet in 400 s +2000 V. The linear calibration plots ranging from 10 to 1000 muM with regression coefficients better than 0.996 were obtained. The injection-to-injection reproducibility of 1.24% (n = 7) for glucose in peak current and 0.6% for migration times were excellent. The detection limit was low, down to 2.3 muM for glucose (SIN = 3) or 27.6 attomole in mass detection. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:210 / 216
页数:7
相关论文
共 50 条
  • [41] Electrochemical detection modes for microchip capillary electrophoresis
    Xu, Jing-Juan
    Wang, Ai-Jun
    Chen, Hong-Yuan
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (02) : 125 - 132
  • [42] Applications of Capillary Electrophoresis and Microchip Capillary Electrophoresis for Detection of Genetically Modified Organisms
    Guo, Longhua
    Qiu, Bin
    Xiao, Xueyang
    Chen, Guonan
    FOOD SCIENCE AND BIOTECHNOLOGY, 2009, 18 (04) : 823 - 832
  • [43] Combination of flow injection with capillary electrophoresis - Part 7. Microchip capillary electrophoresis system with flow injection sample introduction and amperometric detection
    Fu, CG
    Fang, ZL
    ANALYTICA CHIMICA ACTA, 2000, 422 (01) : 71 - 79
  • [44] Recent advances in chemiluminescence detection coupled with capillary electrophoresis and microchip capillary electrophoresis
    Liu, Yuxuan
    Huang, Xiangyi
    Ren, Jicun
    ELECTROPHORESIS, 2016, 37 (01) : 2 - 18
  • [45] Amperometric detection in capillary electrophoresis with on etched joint
    Hu, S
    Wang, ZL
    Li, PB
    Cheng, JK
    ANALYTICAL CHEMISTRY, 1997, 69 (02) : 264 - 267
  • [46] Powder microelectrodes for capillary electrophoresis with amperometric detection
    Hu, S
    Zhang, M
    Pang, DW
    Cheng, JK
    ANALYTICAL SCIENCES, 2000, 16 (08) : 807 - 810
  • [47] New microsystem of capillary electrophoresis with amperometric detection
    Wu, YY
    Wu, MJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (02) : 138 - 141
  • [48] Powder Microelectrodes for Capillary Electrophoresis with Amperometric Detection
    Shen Hu
    Min Zhang
    Dai-Wen Pang
    Jie-Ke Cheng
    Analytical Sciences, 2000, 16 : 807 - 810
  • [49] Square wave amperometric detection for capillary electrophoresis
    Xie, TY
    Li, N
    Tang, YJ
    Ruan, XL
    Mo, JY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (03): : 410 - 413
  • [50] Enhanced determination of glucose by microchip electrophoresis with pulsed amperometric detection
    García, CD