Marrow Adipose Tissue Quantification of the Lumbar Spine by Using Dual-Energy CT and Single-Voxel 1H MR Spectroscopy: A Feasibility Study

被引:58
|
作者
Bredella, Miriam A. [1 ]
Daley, Scott M. [1 ]
Kalra, Mannudeep K. [1 ]
Brown, J. Keenan [3 ,4 ]
Miller, Karen K. [2 ]
Torriani, Martin [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Neuroendocrine Unit, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA 02114 USA
[4] Mindways Software, Austin, TX USA
关键词
BONE-MINERAL DENSITY; COMPUTED-TOMOGRAPHY; FAT-CONTENT; ANOREXIA-NERVOSA; QUANTITATIVE CT; OSTEOPOROSIS; QCT; ABSORPTIOMETRY; FRAGILITY; ACCURACY;
D O I
10.1148/radiol.2015142876
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To test the performance of dual-energy computed tomography (CT) in the assessment of marrow adipose tissue (MAT) content of the lumbar spine by using proton (hydrogen 1 [H-1]) magnetic resonance (MR) spectroscopy as a reference standard and to determine the influence of MAT on the assessment of bone mineral density (BMD). Materials and Methods: This study was institutional review board approved and complied with HIPAA guidelines. Written informed consent was obtained. Twelve obese osteopenic but otherwise healthy subjects (mean age 6 standard deviation, 43 years 6 13) underwent 3-T H-1 MR spectroscopy of the L2 vertebra by using a point-resolved spatially localized spectroscopy sequence without water suppression. The L2 vertebra was scanned with dual-energy CT (80 and 140 kV) by using a dual-source multi-detector row CT scanner with a calibration phantom. Mean basis material composition relative to the phantom was estimated in the L2 vertebra. Volumetric BMD was measured with and without correction for MAT. Bland-Altman 95% limits of agreement and Pearson correlation coefficients were calculated. Results: There was excellent agreement between H-1 MR spectroscopy and dual-energy CT, with a mean difference in fat fraction of 20.02 between the techniques, with a 95% confidence interval of 20.24, 0.20. There was a strong correlation between marrow fat fraction obtained with H-1 MR spectroscopy and that obtained with dual-energy CT (r = 0.91, P < .001). The presence of MAT led to underestimation of BMD, and this bias increased with increasing MAT content (P <.001). Conclusion: Dual-energy CT can be used to assess MAT content and BMD of the lumbar spine in a single examination and provides data that closely agree and correlate with 1H MR spectroscopy data. (C) RSNA, 2015
引用
收藏
页码:230 / 235
页数:6
相关论文
共 32 条
  • [31] Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: A prospective feasibility study on a single-source volume CT scanner
    Diekhoffa, T.
    Hermann, K. G.
    Pumberger, M.
    Hamm, B.
    Putzier, M.
    Fuchs, M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 59 - 65
  • [32] A study of long-term GABA and high-energy phosphate alterations in the primary motor cortex using anodal tDCS and 1H/31P MR spectroscopy
    Patel, Harshal Jayeshkumar
    Stollberg, Lea-Sophie
    Choi, Chang-Hoon
    Nitsche, Michael A.
    Shah, N. Jon
    Binkofski, Ferdinand
    FRONTIERS IN HUMAN NEUROSCIENCE, 2024, 18