Detection of occlusal caries in primary teeth using swept source optical coherence tomography

被引:33
|
作者
Nakajima, Yukie [1 ]
Shimada, Yasushi [2 ]
Sadr, Alireza [2 ]
Wada, Ikumi [2 ]
Miyashin, Michiyo [1 ]
Takagi, Yuzo [1 ]
Tagami, Junji [3 ]
Sumi, Yasunori [4 ]
机构
[1] Tokyo Med & Dent Univ, Dept Orofacial Dev & Funct, Bunkyo Ku, Tokyo 1138549, Japan
[2] Tokyo Med & Dent Univ, Dept Restorat Sci, Bunkyo Ku, Tokyo 1138549, Japan
[3] Tokyo Med & Dent Univ, Dept Cariol & Operat Dent, Global Ctr Excellence GCOE Program, Bunkyo Ku, Tokyo 1138549, Japan
[4] Natl Ctr Geriatr & Gerontol, Dept Adv Dent Res, Ctr Adv Med Dent & Oral Dis, Obu, Aichi 4748511, Japan
基金
日本学术振兴会;
关键词
optical coherence tomography; primary teeth; occlusal caries; detection; sensitivity; specificity; CONVENTIONAL METHODS; DENTIN CARIES; IN-VITRO; SS-OCT; ENAMEL; LESIONS; PERFORMANCE; PROGRESSION; PREVALENCE; FRACTURES;
D O I
10.1117/1.JBO.19.1.016020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study aimed to investigate swept source optical coherence tomography (SS-OCT) as a detecting tool for occlusal caries in primary teeth. At the in vitro part of the study, 38 investigation sites of occlusal fissures (noncavitated and cavitated) were selected from 26 extracted primary teeth and inspected visually using conventional dental equipment by six examiners without any magnification. SS-OCT cross-sectional images at 1330-nm center wavelength were acquired on the same locations. The teeth were then sectioned at the investigation site and directly viewed under a confocal laser scanning microscope (CLSM) by two experienced examiners. The presence and extent of caries were scored in each observation. The results obtained from SS-OCT and conventional visual inspections were compared with those of CLSM. Consequently, SS-OCT could successfully detect both cavitated and noncavitated lesions. The magnitude of sensitivity for SS-OCT was higher than those for visual inspection (sensitivity of visual inspection and SS-OCT, 0.70 versus 0.93 for enamel demineralization, 0.49 versus 0.89 for enamel cavitated caries, and 0.36 versus 0.75 for dentin caries). Additionally, occlusal caries of a few clinical cases were observed using SS-OCT in vivo. The results indicate that SS-OCT has a great detecting potential for occlusal caries in primary teeth. (C) 2014 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Validation of swept-source optical coherence tomography (SS-OCT) for the diagnosis of occlusal caries
    Shimada, Yasushi
    Sadr, Alireza
    Burrow, Michael F.
    Tagami, Junji
    Ozawa, Nobuyoshi
    Sumi, Yasunori
    [J]. JOURNAL OF DENTISTRY, 2010, 38 (08) : 655 - 665
  • [2] Evaluating a novel fissure caries model using swept source optical coherence tomography
    Liu, Xiaozhou
    Jones, Robert S.
    [J]. DENTAL MATERIALS JOURNAL, 2013, 32 (06) : 906 - 912
  • [3] The advantages of a swept source optical coherence tomography system in the evaluation of occlusal disorders
    Marcauteanu, Corina
    Bradu, Adrian
    Sinescu, Cosmin
    Topala, Florin Ionel
    Negrutiu, Meda Lavinia
    Duma, Virgil Florin
    Podoleanu, Adrian Gh.
    [J]. FIFTH INTERNATIONAL CONFERENCE ON LASERS IN MEDICINE: BIOTECHNOLOGIES INTEGRATED IN DAILY MEDICINE, 2014, 8925
  • [4] Speckle variance detection of microvasculature using swept-source optical coherence tomography
    Mariampillai, Adrian
    Standish, Beau A.
    Moriyama, Eduardo H.
    Khurana, Mamta
    Munce, Nigel R.
    Leung, Michael K. K.
    Jiang, James
    Cable, Alex
    Wilson, Brian C.
    Vitkin, I. Alex
    Yang, Victor X. D.
    [J]. OPTICS LETTERS, 2008, 33 (13) : 1530 - 1532
  • [5] Optical analysis of enamel and dentin caries in relation to mineral density using swept-source optical coherence tomography
    Ueno, Tomoka
    Shimada, Yasushi
    Matin, Khairul
    Zhou, Yuan
    Wada, Ikumi
    Sadr, Alireza
    Sumi, Yasunori
    Tagami, Junji
    [J]. JOURNAL OF MEDICAL IMAGING, 2016, 3 (03)
  • [6] Swept Source Optical Coherence Tomography: a Review
    Yasin Alibhai A.
    Or C.
    Witkin A.J.
    [J]. Current Ophthalmology Reports, 2018, 6 (1) : 7 - 16
  • [7] Characterization of enamel in primary teeth by optical coherence tomography for assessment of dental caries
    Maia, Ana M. A.
    Fonseca, Deborah D. D.
    Kyotoku, Bernardo B. C.
    Gomes, Anderson S. L.
    [J]. INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2010, 20 (02) : 158 - 164
  • [8] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    [J]. ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [9] Fingerprint detection using full-field swept-source optical coherence tomography
    Dubey, Satish Kumar
    Anna, Tulsi
    Shakher, Chandra
    Mehta, Dalip Singh
    [J]. APPLIED PHYSICS LETTERS, 2007, 91 (18)
  • [10] Imaging Natural Occlusal Caries Lesions with Optical Coherence Tomography
    Douglas, Shane M.
    Fried, Daniel
    Darling, Cynthia L.
    [J]. LASERS IN DENTISTRY XVI, 2010, 7549