Evaluation of Two Handheld Point-of-Care Blood Gas Analyzers in Healthy Donkeys

被引:1
|
作者
Bonelli, Francesca [1 ]
Laus, Fulvio [2 ]
Briganti, Angela [1 ]
Evangelista, Flavia [1 ]
Bazzano, Marilena [2 ]
Conte, Giuseppe [3 ]
Sgorbini, Micaela [1 ]
机构
[1] Univ Pisa, Dept Vet Sci, Pisa, Italy
[2] Univ Camerino, Sch Biosci & Vet Med, Macerata, Italy
[3] Univ Pisa, Dept Agr Food & Environm, Pisa, Italy
关键词
Blood gas analysis; Donkey; Point-of-care testing; Arterial blood gas analysis; Venous blood gas analysis; GASTRIC-ULCER; EQUUS-ASINUS; ELECTROLYTE CONCENTRATIONS; PARTIAL PRESSURES; HEMATOLOGY; PARAMETERS; HEMOGRAM; DISEASES; BIRTH; FOALS;
D O I
10.1016/j.jevs.2019.05.026
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
There has been increasing interest in blood gas analysis in donkeys. "Point-of-care (POC) testing" is a diagnostic testing performed on or immediately next to the patient. This study assesses the agreement between two POC blood gas analyzers in donkeys. Arterial and venous blood samples were collected from 17 donkeys and analyzed using a fully automated blood gas analyzer (ABL 700 Series Radiometer, Denmark) (RAD) and two POC blood gas analyzers (i-STAT System; VetStat, Idexx). The parameters revealed by all three devices were submitted to a canonical discriminant analysis, to evaluate which parameters differentiated the POC analyzers from the RAD. On the basis of the discriminant analysis, we evaluated the best POC for each parameter registered, in comparison with RAD. The results also changed depending on the type of blood (venous or arterial blood). The agreement between i-STAT and RAD was good for venous samples, but was poor for arterial samples. A poor agreement was found between VetStat and RAD for both venous and arterial samples. The increment of the number of subjects might lead to a better understanding of the potential role of the POCs in clinical setting. Finally, increasing the study population is recommended to set reference values. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:94 / 99
页数:6
相关论文
共 50 条
  • [1] Comparison of 4 point-of-care blood gas analyzers for arterial blood gas analysis in healthy dogs and dogs with cardiopulmonary disease
    Roels, Elodie
    Gommeren, Kris
    Farnir, Frederic
    Delvaux, Francois
    Billen, Frederic
    Clercx, Cecile
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2016, 26 (03) : 352 - 359
  • [2] Evaluation of a new handheld point-of-care blood gas analyser using 100 equine blood samples
    Bardell, David
    West, Eleanor
    Senior, J. Mark
    [J]. VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (01) : 77 - 85
  • [3] Intraosseous Blood Correlates with Venous Blood in Healthy Subjects Using Point-of-Care Analyzers
    Montez, D. F.
    Puga, T. A.
    Garcia, M. R.
    Miller, L. J.
    Davlantes, C.
    Saussy, J. M.
    Philbeck, T. E., Jr.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2013, 62 (04) : S40 - S40
  • [4] Evaluation of two HbA1c point-of-care analyzers
    Sanchez-Mora, Catalina
    Rodriguez-Oliva, Manuel S.
    Fernandez-Riejos, Patricia
    Mateo, Joaquin
    Polo-Padillo, Juan
    Goberna, Raimundo
    Sanchez-Margalet, Victor
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (04) : 653 - 657
  • [5] Comparison of point-of-care and central laboratory analyzers for blood gas and lactate measurements
    Indrasari, Nuri Dyah
    Wonohutomo, Jessica Purwanti
    Sukartini, Ninik
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2019, 33 (05)
  • [6] Point-of-care blood gas analysers: a performance evaluation
    St-Louis, P
    [J]. CLINICA CHIMICA ACTA, 2001, 307 (1-2) : 139 - 144
  • [7] Interchangeability of blood gas, electrolyte and metabolite results measured with point-of-care, blood gas and core laboratory analyzers
    Leino, Aila
    Kurvinen, Kaisa
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (07) : 1187 - 1191
  • [8] Evaluation of a point-of-care blood glucose monitor in healthy goats
    Quandt, Jane E.
    Barletta, Michele
    Cornell, Karen K.
    Giguere, Steeve
    Hofmeister, Erik H.
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2018, 28 (01) : 45 - 53
  • [9] Point-of-care blood gas analyzers have an impact on the acceptance of donor lungs for transplantation
    Marklin, Gary F.
    Bresler, Robert
    Dhar, Rajat
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (08): : 623 - 629
  • [10] COMPARISON OF SIEMENS 405 AND EPOC POINT-OF-CARE BLOOD GAS ANALYZERS WITH SIEMENS 865
    Van Even, Ellen
    Ghys, Tim
    De Puydt, Hendrik
    Louagie, Henk
    [J]. ACTA CLINICA BELGICA, 2012, 67 (01): : 61 - 61