Dual source Fourier transform polarization modulation spectroscopy: An improved method for the measurement of circular and linear dichroism

被引:25
|
作者
Nafie, LA [1 ]
Buijs, H
Rilling, A
Cao, XL
Dukor, RK
机构
[1] Syracuse Univ, Dept Chem, Syracuse, NY 13244 USA
[2] ABB Bomem, East, PQ G1K 9H4, Canada
[3] BioTools Inc, Unit 123, Wauconda, IL 60084 USA
关键词
Fourier transform infrared; polarization modulation; vibrational circular dichroism; vibrational linear dichroism; signal-to-noise ratio optimization;
D O I
10.1366/000370204872926
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
It is shown that the use of two sources in a four-port interferometer equipped with cube-corner mirrors leads to increased signal-to-noise ratios in Fourier transform (FT-IR) circular and linear dichroism spectra. The output beam to the sample is a superposition of two interferograms, one from each source, having opposite Fourier phases. These two interferograms cancel one another to the degree that the two sources are matched in intensity. If the radiation from each of the two sources is first polarized orthogonally with respect to the other and passed through a polarization modulator before reaching the sample, the resulting polarization-modulation interferograms are out of Fourier phase and out of polarization-modulation phase. As a result, the polarization-modulation interferograms, due to circular or linear dichroism in the sample, from the two sources combine positively rather than negatively. An improvement in signal-to-noise ratio of up to two (or a factor of four in scan-time reduction for the same signal-to-noise ratio) compared to single source operation can be realized, while at the same time, the potential for saturation of the detector signal is significantly reduced due to the reduction in magnitude of the combined ordinary infrared transmission interferogram. Absorption and circular dichroism spectra from a dual-source FT-IR spectrometer are presented and analyzed.
引用
收藏
页码:647 / 654
页数:8
相关论文
共 50 条
  • [31] Development of a polarization-modulation spectroscopy system for the temporally resolved measurement of linear polarization in plasma emission
    Yasui, Kenji
    Shikama, Taiichi
    Higashi, Takanori
    Hasuo, Masahiro
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (10):
  • [32] Modified linear and circular carrier frequency Fourier transform method applied for studies of vibrating microelements
    Kacperski, J
    Kujawinska, M
    Krezel, J
    OPTICAL MICRO- AND NANOMETROLOGY IN MANUFACTURING TECHNOLOGY, 2004, 5458 : 287 - 298
  • [33] Visible Fourier transform absorption spectrum measurement method based on dual interferometer configuration
    Wang, Xuzhu
    Lin, Jin
    Song, Chaonan
    Zhu, Lina
    Wang, Shuxing
    OSA CONTINUUM, 2021, 4 (03): : 1010 - 1018
  • [34] A New Method for the Measurement of the Water Activity or Relative Humidity by Fourier Transform Infrared Spectroscopy
    Choosri, Tuchpong
    Koglbauer, Gerald
    Wendland, Martin
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2009, 54 (04): : 1179 - 1182
  • [35] Monochromatic light measurement via geometric phase and Fourier-transform spectroscopy method
    Florin Garoi
    Ionut Nicolae
    Petronela Prepelita
    Scientific Reports, 12
  • [36] Monochromatic light measurement via geometric phase and Fourier-transform spectroscopy method
    Garoi, Florin
    Nicolae, Ionut
    Prepelita, Petronela
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [37] Improved Fourier transform phase measurement method for measuring the quality parameters of an image intensifier
    Sun, Song
    Cao, Yiping
    Wang, Yapin
    Chen, Cheng
    Fu, Guangkai
    Xu, Xingfen
    OPTICAL ENGINEERING, 2017, 56 (03)
  • [38] Frequency-modulation Fourier transform spectroscopy:: a broadband method for measuring weak absorptions and dispersions
    Mandon, Julien
    Guelachvili, Guy
    Picque, Nathalie
    OPTICS LETTERS, 2007, 32 (15) : 2206 - 2208
  • [39] Single crystal circular and linear dichroism of transition metal ion complexes by means of visible and infrared rapid- and step-scan Fourier transform spectroscopy with mirage detection
    Palmer, RA
    Boccara, AC
    Fournier, D
    Briat, B
    9TH INTERNATIONAL CONFERENCE ON PHOTOACOUSTIC AND PHOTOTHERMAL PHENOMENA, CONFERENCE DIGEST, 1996, : 171 - 171
  • [40] Improved method for determination of pectin degree of esterification by diffuse reflectance Fourier transform infrared spectroscopy
    Monsoor, MA
    Kalapathy, U
    Proctor, A
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (06) : 2756 - 2760