Quantitation of right ventricular volumes and ejection fraction by three-dimensional echocardiography in patients: Comparison with magnetic resonance imaging and radionuclide ventriculography

被引:94
|
作者
Nesser, H. Joachim
Tkalec, Wolfgang
Patel, Ayan R.
Masani, Navroz D.
Niel, J.
Markt, Bernhard
Pandian, Natesa G.
机构
[1] Publ Hosp Elisabethinen, Dept Cardiol, Linz, Austria
[2] Tufts Univ New England Med Ctr, Cardiovasc Imaging & Hemodynam Lab, Boston, MA USA
关键词
three-dimensional echocardiography; right ventricular volumes; magnetic resonance imaging; radionuclide ventriculography;
D O I
10.1111/j.1540-8175.2006.00286.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three-dimensional echocardiography (3DE) provides volumetric measurements without geometric assumptions. Volume-rendered 3DE has been shown to be accurate for the measurement of right ventricular (RV) volumes in vitro and in animal studies; however, few data are available regarding its accuracy in patients. This study examined the accuracy of 3DE for quantitation of RV volumes and ejection fraction (EF) in patients, compared to magnetic resonance imaging (MRI) and radionuclide ventriculography (RNV). Twenty patients underwent MRI, gated equilibrium RNV, and 3DE using rotational acquisition from both the transesophageal and transthoracic approaches. RV volumes and EF were calculated from the 3DE data using multislice analysis (true Simpson's rule). RV volumes calculated by MRI (end-diastolic volume (EDV) 109.4 +/- 34.3 mls, end-systolic volume (ESV) 59.6 +/- 31.0 mls, and EF 47.7 +/- 17.1%) agreed closely with 3DE. For transesophageal echocardiography, EDV was 108.1 +/- 29.7 mls (r = 0.86, mean difference 1.3 +/- 17.8 mls); ESV was 62.5 +/- 23.8 mls (r = 0.85, mean difference 2.8 +/- 15.1 mls); and EF was 43.2 +/- 11.7% (r = 0.84, mean difference 4.5 +/- 9.7%). For transthoracic echocardiography, EDV was 107.7 +/- 27.5mls (r = 0.85, mean difference 1.6 +/- 18.2mls); ESV was 59.7 +/- 22.1 mls (r = 0.93, mean difference 3.2 +/- 19.6 mls); and EF was 45.2 +/- 11.5% (r = 0.86, mean difference 2.0 +/- 9.4%). There were close correlations, small mean differences and narrow limits of agreement between RNV-derived EF (43.4 +/- 12.1%) and both transesophageal (r = 0.95 mean difference 0.2 +/- 3.7%) and transthoracic 3DE (r = 0.95, mean difference 1.8 +/- 5.4%). Three-dimensional echocardiography is a promising new method of calculating RV volumes and EF, comparing well with MRI and RNV. The accuracy of transthoracic 3DE was comparable to that of the transesophageal approach. Three-dimensional echocardiography has the potential to be useful in the clinical assessment of RV disorders.
引用
收藏
页码:666 / 680
页数:15
相关论文
共 50 条
  • [1] Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable?
    Bellenger, NG
    Burgess, MI
    Ray, SG
    Lahiri, A
    Coats, AJS
    Cleland, JGF
    Pennell, DJ
    EUROPEAN HEART JOURNAL, 2000, 21 (16) : 1387 - 1396
  • [2] Quantification of left ventricular volumes and ejection fraction using freehand transthoracic three-dimensional echocardiography: Comparison with magnetic resonance imaging
    Mannaerts, HFJ
    van der Heide, JA
    Kamp, O
    Papavassiliu, T
    Marcus, JT
    Beek, A
    van Rossum, AC
    Twisk, J
    Visser, CA
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (02) : 101 - 109
  • [3] Assessment of right ventricular volumes, mass and ejection fraction by matrix array three-dimensional echocardiography in pediatric patients with congenital heart disease: A comparison with magnetic resonance imaging
    Hoch, Martin
    Soriano, Brian
    Kussman, Barry
    Powell, Andrew J.
    Geva, Tal
    Marx, Gerald R.
    CIRCULATION, 2006, 114 (18) : 639 - 639
  • [4] Measurements and day-to-day variabilities of left ventricular volumes and ejection fraction by three-dimensional echocardiography and comparison with magnetic resonance imaging
    Nosir, YFM
    Lequin, MH
    Kasprzak, JD
    van Domburg, RT
    Vletter, WB
    Yao, JF
    Stoker, J
    Ten Cate, FJ
    Roelandt, JRTC
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (02): : 209 - 214
  • [5] Reproducibility and day to day variabilities of three-dimensional echocardiography for left ventricular volumes and ejection fraction calculation with comparison to magnetic resonance imaging
    Nosir, YFM
    Lequin, MH
    Kasprzak, JD
    Vletter, WB
    DallAgata, A
    Stoker, J
    vanDomburg, RT
    Fioretti, PJ
    Roelandt, JRTC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 7052 - 7052
  • [6] Right Ventricular Volumes, Ejection Fraction and Longitudinal Strain Assessed by Three-dimensional Speckle Tracking Echocardiography: Comparisons With Cardiac Magnetic Resonance Imaging
    Xie, Mingxing
    Wan, Xiaojing
    Zhang, Yanting
    Sun, Wei
    Wang, Yushan
    Zhang, Li
    Yang, Yali
    Wang, Jing
    Lv, Qing
    Shi, Heshui
    Li, Yuman
    CIRCULATION, 2019, 140
  • [7] Quantitative Assessment of Right Ventricular Volumes and Ejection Fraction in Patients with Left Ventricular Systolic Dysfunction by Real Time Three-Dimensional Echocardiography versus Cardiac Magnetic Resonance Imaging
    Kim, Jiwon
    Cohen, Scott B.
    Atalay, Michael K.
    Maslow, Andrew D.
    Poppas, Athena
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (05): : 805 - 812
  • [8] Quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography: comparison with cardiovascular magnetic resonance
    Claver, E.
    Leta, R.
    Pujadas, S.
    Kociubinski, P. A.
    Costa, F. Carreras
    Pons-Llado, G.
    EUROPEAN HEART JOURNAL, 2005, 26 : 314 - 314
  • [9] Partition values for normal left and right ventricular volumes and ejection fraction by three-dimensional echocardiography
    Gopal, AS
    Krishnaswamy, R
    Toole, R
    Schapiro, W
    Reichek, N
    EUROPEAN HEART JOURNAL, 2004, 25 : 341 - 341
  • [10] Three-dimensional transthoracic echocardiographic measurements of the right ventricular volumes and ejection fraction in human: a validation study with magnetic resonance imaging
    Fujimoto, S
    Mizuno, R
    Dohi, K
    Nakano, H
    CIRCULATION, 1998, 98 (17) : 701 - 701