A STATCOM with Supercapacitors for Low-Voltage Ride-Through in Fixed-Speed Wind Turbines

被引:13
|
作者
Felipe Obando-Montano, Andres [1 ]
Carrillo, Camilo [1 ]
Cidras, Jose [1 ]
Diaz-Dorado, Eloy [1 ]
机构
[1] Univ Vigo, Dept Elect Engn, EEI, Vigo 36310, Spain
关键词
wind energy; fixed-speed wind generator; STATCOM; supercapacitor; low-voltage ride-through; ENERGY-STORAGE SYSTEM; STABILITY IMPROVEMENT; CONVERTERS; FARMS;
D O I
10.3390/en7095922
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Fixed-speed wind generator (FSWG) technology has an important presence in countries where wind energy started to be developed more than a decade ago. This type of technology cannot be directly adapted to the grid codes, for example those requirements related to the immunity level under voltage dips. That behavior is typically referred as low-voltage ride through (LVRT), and it usually implies certain reactive and active power injection requirements, both during a voltage dip and during the voltage recovery. In this context, a review is presented of the LVRT exigencies present in some of the countries with the most advanced grid codes (Denmark, Germany, Spain and the United Kingdom). In this paper, the capabilities of STATCOM-based devices for fulfilling the LVRT requirements in FSWGs are analyzed. For this purpose, two technologies are considered: a STATCOM with a supercapacitor, which improves its energy storage features; and a STATCOM with a supercapacitor and a DC-DC converter, to achieve higher discharge levels.
引用
收藏
页码:5922 / 5952
页数:31
相关论文
共 50 条
  • [11] Low-voltage Ride-through Capability Characterization of Wind Farms
    Awad, A. S.
    Abdel-Rahman, M.
    Badr, M. Abdel Latif
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (16) : 1808 - 1819
  • [12] Impact of fault ride-through requirements on fixed-speed wind turbine structural loads
    Hansen, Anca D.
    Cutululis, Nicolaos A.
    Markou, Helen
    Sorensen, Poul E.
    WIND ENERGY, 2011, 14 (01) : 1 - 11
  • [13] Robust STATCOM control for the stabilisation of fixed-speed wind turbines during low voltages
    Hossain, M. J.
    Pota, H. R.
    Ramos, R. A.
    RENEWABLE ENERGY, 2011, 36 (11) : 2897 - 2905
  • [14] Enhancement of the Dynamic Behavior of the Low Voltage Ride-Through Wind Turbines
    Saidi, Abdelaziz Salah
    Helmy, Walid
    2018 9TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2018,
  • [15] Fault analysis of doubly fed induction generator wind turbines with low-voltage ride-through capability
    Bi, Tian-Shu
    Liu Su-Mei
    Xue, An-Cheng
    Yang, Qi-Xun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2013, 41 (02): : 26 - 31
  • [16] STATCOM modeling Impact on Wind Turbines' Low Voltage Ride Through Capability
    Awad, A. S. A.
    Salama, M. M. A.
    El Shatshat, Ramadan
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [17] Application of STATCOM-supercapacitor for low-voltage ride-through capability in DFIG-based wind farm
    Dosoglu, M. K.
    Arsoy, A. Basa
    Guvenc, U.
    NEURAL COMPUTING & APPLICATIONS, 2017, 28 (09): : 2665 - 2674
  • [18] Application of STATCOM-supercapacitor for low-voltage ride-through capability in DFIG-based wind farm
    M. K. Döşoğlu
    A. Basa Arsoy
    U. Güvenç
    Neural Computing and Applications, 2017, 28 : 2665 - 2674
  • [19] A comprehensive review of low-voltage-ride-through methods for fixed-speed wind power generators
    Moghadasi, Amirhasan
    Sarwat, Arif
    Guerrero, Josep M.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 55 : 823 - 839
  • [20] Pitch Control for Improving the Low-Voltage Ride-Through of Wind Farm
    Aung, Ko Thet
    Saitoh, Hiroumi
    T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC, 2009, : 84 - +