A STATCOM with Supercapacitors for Low-Voltage Ride-Through in Fixed-Speed Wind Turbines

被引:13
|
作者
Felipe Obando-Montano, Andres [1 ]
Carrillo, Camilo [1 ]
Cidras, Jose [1 ]
Diaz-Dorado, Eloy [1 ]
机构
[1] Univ Vigo, Dept Elect Engn, EEI, Vigo 36310, Spain
关键词
wind energy; fixed-speed wind generator; STATCOM; supercapacitor; low-voltage ride-through; ENERGY-STORAGE SYSTEM; STABILITY IMPROVEMENT; CONVERTERS; FARMS;
D O I
10.3390/en7095922
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Fixed-speed wind generator (FSWG) technology has an important presence in countries where wind energy started to be developed more than a decade ago. This type of technology cannot be directly adapted to the grid codes, for example those requirements related to the immunity level under voltage dips. That behavior is typically referred as low-voltage ride through (LVRT), and it usually implies certain reactive and active power injection requirements, both during a voltage dip and during the voltage recovery. In this context, a review is presented of the LVRT exigencies present in some of the countries with the most advanced grid codes (Denmark, Germany, Spain and the United Kingdom). In this paper, the capabilities of STATCOM-based devices for fulfilling the LVRT requirements in FSWGs are analyzed. For this purpose, two technologies are considered: a STATCOM with a supercapacitor, which improves its energy storage features; and a STATCOM with a supercapacitor and a DC-DC converter, to achieve higher discharge levels.
引用
收藏
页码:5922 / 5952
页数:31
相关论文
共 50 条
  • [1] Low voltage ride-through improvement for fixed-speed wind turbines based on full power converters
    Huang, W. (hwhuang@mail.iee.ac.cn), 2013, Automation of Electric Power Systems Press (37):
  • [2] Low voltage ride-through enhancement of fixed-speed wind farms using series FACTS controllers
    Mohammadpour, Hossein Ali
    Ghaderi, Amin
    Mohammadpour, Hassan
    Ali, Mohd. Hasan
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2015, 9 : 12 - 21
  • [3] Low-Voltage Ride-Through of Variable Speed Wind Turbines with Permanent Magnet Synchronous Generator
    Deng, Fujin
    Chen, Zhe
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 581 - +
  • [4] Improved low-voltage-ride-through capability of fixed-speed wind turbines using decentralised control of STATCOM with energy storage system
    Hossain, M. J.
    Pota, H. R.
    Ramos, R. A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (08) : 719 - 730
  • [5] Low-Voltage Ride-Through Remote Testing Method for Offshore Wind Turbines
    Jiang, Zimin
    Liu, Yutian
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (06) : 2905 - 2913
  • [6] Low-Voltage Ride-Through Techniques in DFIG-Based Wind Turbines: A Review
    Qin, Boyu
    Li, Hengyi
    Zhou, Xingyue
    Li, Jing
    Liu, Wansong
    APPLIED SCIENCES-BASEL, 2020, 10 (06):
  • [7] A Cut-Out Strategy for Wind Turbines that Ensures Low-Voltage Ride-Through Capability
    Aiguo Tan
    Zhihan Tang
    Xianbo Sun
    Jianwei Zhong
    Honghua Liao
    Haibing Fang
    Journal of Electrical Engineering & Technology, 2020, 15 : 1567 - 1575
  • [8] Low-voltage ride-through strategy for offshore wind turbines based on current relaxation region
    Yang, Zhichao
    Gao, Bingtuan
    Cao, Zeyu
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
  • [9] A Cut-Out Strategy for Wind Turbines that Ensures Low-Voltage Ride-Through Capability
    Tan, Aiguo
    Tang, Zhihan
    Sun, Xianbo
    Zhong, Jianwei
    Liao, Honghua
    Fang, Haibing
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (04) : 1567 - 1575
  • [10] Improvement of the Low-voltage Ride-through Capability of Doubly Fed Induction Generator Wind Turbines
    Ling, Yu
    Dou, Zhenlan
    Gao, Qiang
    Cai, Xu
    WIND ENGINEERING, 2012, 36 (05) : 535 - 551