Dynamic performance of a novel solar photovoltaic/loop-heat-pipe heat pump system

被引:92
|
作者
Zhang, Xingxing [1 ]
Zhao, Xudong [1 ]
Shen, Jingchun [1 ]
Xu, Jihuan [2 ]
Yu, Xiaotong [3 ]
机构
[1] Univ Hull, Sch Engn, Kingston Upon Hull HU6 7RX, N Humberside, England
[2] Shanghai Pacific Energy Ctr, Shanghai, Peoples R China
[3] Shanghai Solar Energy Res Ctr, Shanghai, Peoples R China
关键词
PV/Thermal; Loop heat pipe; Heat pump; Dynamic performance; Energy; Exergy; THERMAL COLLECTOR; WATER; ENERGY; MODULE;
D O I
10.1016/j.apenergy.2013.09.063
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Objective of the paper is to present an investigation into the dynamic performance of a novel solar photovoltaic/loop-heat-pipe (PV/LHP) heat pump system for potential use in space heating or hot water generation. The methods used include theoretical computer simulation, experimental verification, analysis and comparison. The fundamental equations governing the transient processes of solar transmission, heat transfer, fluid flow and photovoltaic (PV) power generation were appropriately integrated to address the energy balances occurring in different parts of the system, e.g., glazing cover, PV cells, fin sheet, loop heat pipe, heat pump cycle and water tank. A dedicated computer model was developed to resolve the above grouping equations and consequently predict the system's dynamic performance. An experimental rig was constructed and operated under the real weather conditions for over one week in Shanghai to evaluate the system living performance, which was undertaken by measurement of various operational parameters, e.g., solar radiation, photovoltaic power generation, temperatures and heat pump compressor consumption. On the basis of the first- (energetic) and second- (exergetic) thermodynamic laws, an overall evaluation approach was proposed and applied to conduct both quantitative and qualitative analysis of the PV/LHP module's efficiency, which involved use of the basic thermal performance coefficient (COPth) and the advanced performance coefficient (COPPV/T) of such a system. Moreover, a simple comparison between the PV/LHP heat-pump system and conventional solar/air energy systems was conducted. The research results indicated that under the testing outdoor conditions, the mean daily electrical, thermal and overall energetic and exergetic efficiencies of the PV/LHP module were 9.13%, 39.25%, 48.37% and 15.02% respectively, and the average values of COPth and COPPV/T were 5.51 and 8.71. The PV/LHP module was found to achieve 3-5% higher solar exergetic efficiency than standard PV systems and about 7% higher overall solar energetic efficiency than the independent solar collector. Compared to the conventional solar/air heat pump systems, the PV/LHP heat pump system could achieve a COP figure that is around 1.5-4 times that for the conventional systems. It is concluded that the computer model is able to achieve a reasonable accuracy in predicting the system's dynamic performance. The PV/LHP heat pump system is able to harvest significant amount of solar heat and electricity, thus enabling achieving enhanced solar thermal and electrical efficiencies. All these indicate a positive implication that the proposed system has potential to be developed into a high performance PV/T technology that can contribute to significant fossil fuel energy saving and carbon emission. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:335 / 352
页数:18
相关论文
共 50 条
  • [31] Experimental study of ventilation system with heat recovery integrated by pump-driven loop heat pipe and heat pump
    Liu, Shuailing
    Ma, Guoyuan
    Xu, Shuxue
    Jia, Xiaoya
    Wu, Guoqiang
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 52
  • [32] Thermoelectric performance analysis of the novel direct-expansion photovoltaic thermal heat pump/power heat pipe compound cycle system in summer
    Guo, Xiaochao
    Zhang, Jili
    Han, Youhua
    [J]. APPLIED ENERGY, 2024, 362
  • [33] A loop-heat-pipe heat sink with parallel condensers for high-power integrated LED chips
    Li, Ji
    Lin, Feng
    Wang, Daming
    Tian, Wenkai
    [J]. APPLIED THERMAL ENGINEERING, 2013, 56 (1-2) : 18 - 26
  • [34] Preliminary investigation on the switching time of a photovoltaic solar-assisted heat-pump/heat-pipe hybrid system
    Zhang, Tao
    Zhang, Yufan
    Shi, Zhengrong
    Pei, Gang
    Cai, Jingyong
    [J]. APPLIED ENERGY, 2022, 324
  • [35] The early design stage for building renovation with a novel loop-heat-pipe based solar thermal facade (LHP-STF) heat pump water heating system: Techno-economic analysis in three European climates
    Zhang, Xingxing
    Shen, Jingchun
    Adkins, Deborah
    Yang, Tong
    Tang, Llewellyn
    Zhao, Xudong
    He, Wei
    Xu, Peng
    Liu, Chenchen
    Luo, Huizhong
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 106 : 964 - 986
  • [36] Theoretical investigation of the performance of a novel loop heat pipe solar water heating system for use in Beijing, China
    Zhao, Xudong
    Wang, Zhangyuan
    Tang, Qi
    [J]. APPLIED THERMAL ENGINEERING, 2010, 30 (16) : 2526 - 2536
  • [37] Experimental research on a novel solar water heating system by using loop heat pipe
    Wang, Zhangyuan
    Zhang, Xiangmei
    Yang, Wansheng
    Chen, Zhiwu
    [J]. APPLIED ENERGY TECHNOLOGY, PTS 1 AND 2, 2013, 724-725 : 163 - 170
  • [38] Performance prediction on a novel dual-mode heat pump with a hybrid photovoltaic/micro-channel heat pipe/fin heat exchanger
    Zhang, Yuzhe
    Ji, Jie
    Song, Zhiying
    Ke, Wei
    Xie, Hao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2023, 293
  • [39] Performance of a Hybrid Solar Photovoltaic - Air Source Heat Pump System with Energy Storage
    Lv, Yuexia
    Si, Pengfei
    Liu, Jianmin
    Ling, Wen
    Yan, Jinyue
    [J]. INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 1311 - 1316
  • [40] Experimental study of photovoltaic solar assisted heat pump system
    Ji, Jie
    Pei, Gang
    Chow, Tin-tai
    Liu, Keliang
    He, Hanfeng
    Lu, Jianping
    Han, Chongwei
    [J]. SOLAR ENERGY, 2008, 82 (01) : 43 - 52