Comparison of response properties of the electrically stimulated auditory nerve reported in human listeners and in animal models

被引:3
|
作者
Skidmore, Jeffrey [1 ]
Ramekers, Dyan [2 ,3 ]
Bruce, Ian C. [4 ]
He, Shuman [1 ,5 ]
机构
[1] Ohio State Univ, Eye & Ear Inst, Dept Otolaryngol Head & Neck Surg, 915 Olentangy River Rd, Columbus, OH 43212 USA
[2] Univ Utrecht, Univ Med Ctr Utrecht, Dept Otorhinolaryngol & Head & Neck Surg, Room G-02-531,POB 85500, NL-3508 GA Utrecht, Netherlands
[3] Univ Utrecht, UMC Utrecht Brain Ctr, Utrecht, Netherlands
[4] McMaster Univ, Dept Elect & Comp Engn, 1280 Main St West, Hamilton, ON L8S 4K1, Canada
[5] Nationwide Childrens Hosp, Dept Audiol, 700 Childrens Dr, Columbus, OH 43205 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Electrical stimulation; Animal models; Human cochlear implant users; Auditory nerve; Response characteristics; Electrically evoked auditory compound  action potentials; COCHLEAR IMPLANT USERS; SENSORINEURAL HEARING-LOSS; PULSE-TRAIN STIMULATION; SPIRAL GANGLION-CELLS; ACTION-POTENTIAL ECAP; BRAIN-STEM RESPONSE; NEURAL RESPONSE; RECOVERY FUNCTION; FIBER RESPONSES; GUINEA-PIGS;
D O I
10.1016/j.heares.2022.108643
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Cochlear implants (CIs) provide acoustic information to implanted patients by electrically stimulating nearby auditory nerve fibers (ANFs) which then transmit the information to higher-level neural struc-tures for further processing and interpretation. Computational models that simulate ANF responses to CI stimuli enable the exploration of the mechanisms underlying CI performance beyond the capacity of in vivo experimentation alone. However, all ANF models developed to date utilize to some extent anatomi-cal/morphometric data, biophysical properties and/or physiological data measured in non-human animal models. This review compares response properties of the electrically stimulated auditory nerve (AN) in human listeners and different mammalian models. Properties of AN responses to single pulse stimulation, paired-pulse stimulation, and pulse-train stimulation are presented. While some AN response properties are similar between human listeners and animal models (e.g., increased AN sensitivity to single pulse stimuli with long interphase gaps), there are some significant differences. For example, the AN of most animal models is typically more sensitive to cathodic stimulation while the AN of human listeners is gen-erally more sensitive to anodic stimulation. Additionally, there are substantial differences in the speed of recovery from neural adaptation between animal models and human listeners. Therefore, results from an-imal models cannot be simply translated to human listeners. Recognizing the differences in responses of the AN to electrical stimulation between humans and other mammals is an important step for creating ANF models that are more applicable to various human CI patient populations.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] PCBs and auditory function: From animal models to human infants
    Schantz, SL
    Powers, BE
    Peck, JD
    Lasky, RE
    Fowler, CG
    Sweeney, AM
    NEUROTOXICOLOGY AND TERATOLOGY, 2006, 28 (03) : 417 - 417
  • [42] Impact of electrode placement on spiking probability of a stimulated human auditory nerve fiber
    Tanzer, Thomas
    Sajedi, Sogand
    Rattay, Frank
    JOURNAL OF COMPUTATIONAL NEUROSCIENCE, 2021, 49 (SUPPL 1) : S151 - S151
  • [43] Electrically Evoked Amplitude Modulation Following Response in Cochlear Implant Candidates: Comparison With Auditory Nerve Response Telemetry, Subjective Electrical Stimulation, and Speech Perception
    Hirschfelder, Anke
    Graebel, Stefan
    Olze, Heidi
    OTOLOGY & NEUROTOLOGY, 2012, 33 (06) : 968 - 975
  • [44] Temporal response properties of the auditory nerve: Data from human cochlear-implant recipients
    Hughes, Michelle L.
    Castioni, Erin E.
    Goehring, Jenny L.
    Baudhuin, Jacquelyn L.
    HEARING RESEARCH, 2012, 285 (1-2) : 46 - 57
  • [45] ELECTRICALLY INDUCED AUDITORY BRAIN-STEM RESPONSE AS A CLINICAL TOOL IN ESTIMATING NERVE SURVIVAL
    SIMMONS, FB
    LUSTED, HS
    MYERS, T
    SHELTON, C
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1987, 96 (01): : 92 - 92
  • [46] ELECTRICALLY INDUCED AUDITORY BRAIN-STEM RESPONSE AS A CLINICAL TOOL IN ESTIMATING NERVE SURVIVAL
    SIMMONS, FB
    MEYERS, T
    LUSTED, HS
    SHELTON, C
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1984, 93 (04): : 97 - 100
  • [47] Direct comparison between properties of adaptation of the auditory nerve and the ventral cochlear nucleus in response to repetitive clicks
    Meyer, K.
    Rouiller, E. M.
    Loquet, G.
    HEARING RESEARCH, 2007, 228 (1-2) : 144 - 155
  • [48] Discharge properties of identified cochlear nucleus neurons and auditory nerve fibers in response to repetitive electrical stimulation of the auditory nerve
    Babalian, AL
    Ryugo, DK
    Rouiller, EM
    EXPERIMENTAL BRAIN RESEARCH, 2003, 153 (04) : 452 - 460
  • [49] Discharge properties of identified cochlear nucleus neurons and auditory nerve fibers in response to repetitive electrical stimulation of the auditory nerve
    Alexander L. Babalian
    David K. Ryugo
    Eric M. Rouiller
    Experimental Brain Research, 2003, 153 : 452 - 460
  • [50] Electrically evoked auditory brainstem response by direct electrical stimulation to the cochlear nerve in acoustic neuroma patients
    Tanaka, H
    Komatsuzaki, A
    Okuno, H
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1997, 59 (02): : 67 - 72