Lead Location as Assessed on Cardiac Computed Tomography and Difficulty of Percutaneous Transvenous Extraction

被引:17
|
作者
Patel, Divyang [1 ]
Sripariwuth, Apichaya [2 ]
Abozeed, Mostafa [2 ]
Hussein, Ayman A. [1 ]
Tarakji, Khaldoun G. [1 ]
Wazni, Oussama M. [1 ]
Wilkoff, Bruce L. [1 ]
Schoenhagen, Paul [1 ,2 ]
Bolen, Michael A. [1 ,2 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, 9500 Euclid Ave J1-4, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Diagnost Radiol, Cleveland, OH 44195 USA
关键词
computed tomography; lead extraction;
D O I
10.1016/j.jacep.2019.07.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to retrospectively investigate outcomes of lead extraction by using pre-operative computed tomography (CT) scans to identify risk of complicated lead extraction to aid in pre-procedural planning. BACKGROUND Transvenous lead extractions remain high-risk procedures requiring specialized operators, equipment, and surgical backup. Data are lacking for how to identify difficult lead extractions. CT scans, which can illustrate the proximity of the lead to adherent venous structures can potentially aid in identifying difficult lead extractions. METHODS All cases of patients who were undergoing transvenous lead extractions at the authors' institution between 2015 and 2018, who had a pre-operative CT scan prior to lead extraction, were reviewed. The images were retrospectively reviewed to examine adherence of leads to the surrounding vein and obtained procedural outcomes. RESULTS A total of 203 cases were reviewed of patients undergoing transvenous lead extraction who had a preoperative CT scan, and scans were separated based on lead location in the superior vena cava, as assessed by CT imaging. Scans were divided into 3 groups: those in a central location or <1 cm adherence (n = 28); those that had at least 1 lead with tip adherent >1 cm (n -137); or those that had at least 1 lead outside the vein contour (n = 38). Although there was only 1 serious complication requiring vascular surgery intervention, patients with at least 1 lead outside the vein contour required significantly longer procedural time (190.8 +/- 86.6 min vs. 158.1 +/- 73.7 min vs. 142.8 +/- 52.2 min; p 0.019) and fluoroscopy time (33.1 +/- 24.2 min vs. 19.6 +/- 18.4 min vs. 18.3 +/- 16.4 min; p = 0.0006) than those with leads adhering >1 cm and centrally located leads, respectively. CONCLUSIONS Pre-operative CT scanning can identify difficult lead extractions prior to performing the procedure. This information may aid etectrophysiotogists in the planning of extraction procedures. Future prospective studies are needed to confirm these findings. (C) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:1432 / 1438
页数:7
相关论文
共 50 条
  • [1] Computed tomography predictors of increased transvenous lead extraction difficulty
    Patel, Kavisha
    Toomu, Sandeep
    Lee, Euyhyun
    Darden, Douglas
    Jacobs, Kathleen
    Pollema, Travis
    Ho, Gordon
    Birgersdotter-Green, Ulrika
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (09): : 1232 - 1240
  • [2] VENOUS OCCLUSION DETECTED BY COMPUTED TOMOGRAPHY IS ASSOCIATED WITH TRANSVENOUS LEAD EXTRACTION DIFFICULTY
    Patel, Kavisha
    Toomu, Sandeep
    Jacobs, Kathleen
    Pollema, Travis
    Ho, Gordon
    Birgersdotter-Green, Ulrika
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 30 - 30
  • [3] Transvenous lead extraction, factors affecting procedural difficulty
    Abdelazeem, Ahmed
    Ahmed, Ashraf
    Curnis, Antonio
    Arabia, Gianmarco
    Cerini, Manuel
    Aboelhassan, Mohamed
    Salghetti, Francesca
    Milidoni, Antonino
    Nawar, Mostafa
    Magdy, Gehan
    ACTA CARDIOLOGICA, 2023, 78 (09) : 992 - 999
  • [4] Prospective Evaluation of the Correlation Between Gated Cardiac Computed Tomography Detected Vascular Fibrosis and Ease of Transvenous Lead Extraction
    Patel, Divyang
    Vatterott, Pierce
    Piccini, Jonathan
    Epstein, Laurence M.
    Hakmi, Samer
    Syed, Imran
    Koweek, Lynne M.
    Bolen, Michael
    Schoenhagen, Paul
    Tarakji, Khaldoun G.
    Francis, Nathan
    Shao, Mingyuan
    Wilkoff, Bruce L.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (11): : 740 - 747
  • [5] Computed Tomography-Guided Risk Assessment in Percutaneous Lead Extraction
    Svennberg, Emma
    Jacobs, Kathleen
    McVeigh, Elliot
    Pretorius, Victor
    Birgersdotter-Green, Ulrika
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (12) : 1439 - 1446
  • [6] Total laser cyclesa measure of transvenous lead extraction difficulty
    Elsaid, Ossama
    O'Sullivan, David M.
    Zweibel, Steven
    Cronin, Edmond M.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (03) : 383 - 389
  • [7] PERMANENT TRANSVENOUS LEAD EXTRACTION: FACTORS INFLUENCING THE DIFFICULTY OF THE PROCEDURE
    Bontempi, L.
    Cerini, M.
    Lipari, A.
    Vassanelli, F.
    Salghetti, F.
    Locantore, E.
    Belotti, M.
    D'Aloia, A.
    Vizzardi, E.
    Raweh, A.
    Elmaghawry, M.
    Curnis, A.
    VALUE IN HEALTH, 2013, 16 (07) : A702 - A703
  • [8] Total laser cycles—a measure of transvenous lead extraction difficulty
    Ossama Elsaid
    David M. O’Sullivan
    Steven Zweibel
    Edmond M. Cronin
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 383 - 389
  • [9] The role of preoperative venography in predicting the difficulty of a transvenous lead extraction procedure
    Aboelhassan, Mohamed
    Bontempi, Luca
    Cerini, Manuel
    Salghetti, Francesca
    Arabia, Gianmarco
    Giacopelli, Daniele
    Fouad, Doaa A.
    Abdelmegid, Mohamed Aboel-kassem F.
    Ahmed, Tarek A. N.
    Dell'Aquila, Andrea
    Curnis, Antonio
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (05) : 1034 - 1040
  • [10] Predicting the difficulty of a transvenous lead extraction procedure: Validation of the LED index
    Bontempi, Luca
    Vassanelli, Francesca
    Cerini, Manuel
    Inama, Lorenza
    Salghetti, Francesca
    Giacopelli, Daniele
    Gargaro, Alessio
    Raweh, Abdallah
    Curnis, Antonio
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (07) : 811 - 818