Experimental studies on natural convection of water in a closed-loop vertical annulus

被引:29
|
作者
Mustafa, Jawed [1 ]
Husain, Shahid [1 ]
Siddiqui, M. Altamush [1 ]
机构
[1] Aligarh Muslim Univ, Dept Mech Engn, Aligarh, Uttar Pradesh, India
关键词
natural convection; vertical annulus; closed-loop thermo-siphon; radius ratio; high aspect ratio; constant heat flux; HEAT-TRANSFER; FLOW;
D O I
10.1080/08916152.2015.1135202
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental studies on heat transfer and fluid flow of water in a vertical annulus, circulating through a cold leg forming a closed loop thermo-siphon, have been carried out in this article. The annulus has a radius ratio (outer radius to inner radius) of 1.184 and aspect ratio (length to annular gap) equal to 352. The experiments were conducted for constant heat fluxes of 1, 2.5, 5, 7.5, 10, 12.5, and 15 kW/m(2). Transient behavior during the heat-up period of the system until the steady-state condition is attained and discussed. Variation in the heat transfer coefficient and Nusselt number along the annulus height represent the developing boundary layer at the entrance and fully developed flow in the remaining length. A large drop in the differential pressure is experienced when the liquid is circulated through the flow meters, which restrict the flow due to their very small passages. Flow restriction causes mass accumulation and rise of pressure at the exit of the annulus. It also causes a decrease in liquid head in the cooling leg. An increase in the heat flux leads to an increase in the heat transfer coefficient and Nusselt number. As a result of the data analysis correlations for the average Nusselt number, Reynolds number and circulation rate have been developed in terms of the heat flux.
引用
收藏
页码:25 / 45
页数:21
相关论文
共 50 条
  • [31] Double-diffusive natural convection in a vertical porous annulus
    Beji, H
    Bennacer, R
    Duval, R
    Vasseur, P
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 1999, 36 (02) : 153 - 170
  • [32] CFD simulation and optimization of natural convection in a vertical annulus with nanofluids
    Khan, Suhail Ahmad
    Siddiqui, Mohammad Altamush
    Asjad, Mohammad
    Khan, Zahid A.
    Husain, Shahid
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 185
  • [33] Natural heat and mass convection in a partially porous vertical annulus
    Benzeghiba, M
    Chikh, S
    SIXTH UK NATIONAL CONFERENCE ON HEAT TRANSFER, 1999, 1999 (07): : 475 - 480
  • [34] Natural convection in an annulus between two rotating vertical cylinders
    Venkatachalappa, M
    Sankar, M
    Natarajan, AA
    ACTA MECHANICA, 2001, 147 (1-4) : 173 - 196
  • [35] Closed-loop experimental optimization of tunable lenses
    Lopez -De -Haro, Angel G.
    Barcala, Xoana
    Martinez-Ibarburu, Ivan
    Marrakchi, Yassine
    Gambra, Enrique
    Rodriguez-Lopez, Victor
    Sawides, Lucie
    Dorronsoro, Carlos
    APPLIED OPTICS, 2022, 61 (27) : 8091 - 8099
  • [36] EXPERIMENTAL CLOSED-LOOP CONTROL OF A DISTILLATION COLUMN
    BEAVERST.MC
    HARRIOTT, P
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1973, 12 (04): : 401 - 407
  • [37] FGD WATER MANAGEMENT FOR CLOSED-LOOP OPERATION
    HAMMONTREE, DB
    LANDWEHR, JB
    POWER ENGINEERING, 1987, 91 (12) : 27 - 29
  • [38] Stability Analysis of Closed-loop Water System
    Yongzheng FU Keqi WU Yaqiao CAI School of Energy & Power Engineering
    Journal of Thermal Science, 2006, (02) : 152 - 158
  • [39] Experimental study of turbulent forced convection in vertical eccentric annulus
    Hosseini, R.
    Ramezani, M.
    Mazaheri, M. R.
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (09) : 2266 - 2274
  • [40] Experimental study on natural convection of cold water near the maximum density in horizontal annulus
    Tang, Jing-Wen
    Wang, Lin-Hao
    Gao, Cheng
    Liang, Xin-Li
    Li, Jia
    Chongqing Daxue Xuebao/Journal of Chongqing University, 2009, 32 (10): : 1165 - 1168