Protein crystallography beam line at MIRRORCLE

被引:0
|
作者
Sasaki, M [1 ]
Hirai, T [1 ]
Yamada, H [1 ]
机构
[1] Ritsumeikan Univ, Synchrotron Ligh Life Sci Ctr, Kusatsu, Japan
来源
PORTABLE SYNCHROTRON LIGHT SOURCES AND ADVANCED APPLICATIONS | 2004年 / 716卷
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A Protein crystallography beam line using MIRRORCLE-6X, which is a compact synchrotron for hard x-ray production, is under construction. Since MIRRORCLE-6X provides hard x-ray with high brightness, it is suitable for x-ray source of accurate protein crystallography research in a small laboratory. The divergent x-ray emitted from a target is focused by a condensing mirror. The mirrors used for the condensing mirror are a multi layer mirror of Wolter type and a rotating ellipsoidal mirror. Photon energies dispersed by them are set to the K-edge of Zn and of Se, respectively. The flux at a focusing point is expected to be 10(3) similar to 10(4) times larger than that without the condensing mirror. The focusing size is less than 100 mum of diameter. The x-ray after the mirror is transformed to parallel beam using a Fresnel zone plate and irradiated on a protein crystal. The diffraction figure is detected by the an imaging-plate detector.
引用
收藏
页码:141 / 143
页数:3
相关论文
共 50 条
  • [11] A new mini-beam device for protein crystallography
    Alkire, R. W.
    Molitsky, M.
    Rotella, F. J.
    Lazarski, K.
    Joachimiak, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 649 (01): : 112 - 113
  • [12] A NEW INSTRUMENT FOR PROTEIN CRYSTALLOGRAPHY ON THE WIGGLER BEAM LINE AT THE SRS PROVIDING A FOCUSED, TUNABLE BEAM AT SHORT X-RAY WAVELENGTHS
    HELLIWELL, JR
    PAPIZ, M
    MOORE, PR
    THOMPSON, AW
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C394 - C394
  • [13] Small molecule Crystallography on Macromolecular Biology Beam Line at the ESRF.
    Flot, David
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2012, 68 : S113 - S113
  • [14] Present status of MIRRORCLE-20 for MIR and FIR beam lines
    Moon, Ahsa
    Miura, Nobuhiro
    Kikuzawa, Takeshi
    Yamada, Hironari
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 611 - +
  • [15] Active vibration control method of double crystal monochromator of P2 protein crystallography beam line at SSRF
    Bai Yang
    Gong Xuepeng
    Lu Qipeng
    Song Yuan
    Wang Dazhuang
    Peng Zhongqi
    Zhang Zhen
    Mao Qijun
    Ma Tianyu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1019
  • [16] Protein crystallography with a micrometre-sized synchrotron-radiation beam
    Moukhametzianov, Rouslan
    Burghammer, Manfred
    Edwards, Patricia C.
    Petitdemange, Sebastien
    Popov, Dimitri
    Fransen, Maikel
    McMullan, Gregory
    Schertler, Gebhard F. X.
    Riekel, Christian
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2008, 64 : 158 - 166
  • [17] Protein Micro-Crystallography with a New Micro-Beam Beamline
    Yamamoto, Masaki
    Hirata, Kunio
    Hikima, Takaaki
    Kawano, Yoshiaki
    Ueno, Go
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2010, 130 (05): : 641 - 648
  • [18] An incident-beam monitor for use in protein crystallography at a synchrotron source
    Alkire, RW
    Rotella, FJ
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1997, 30 (pt 3) : 327 - 332
  • [19] PROTEIN CRYSTALLOGRAPHY
    SCHOENBORN, BP
    BIOPHYSICAL JOURNAL, 1983, 41 (02) : A375 - A375
  • [20] PROTEIN CRYSTALLOGRAPHY
    Rossmann, Michael G.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C570 - C570