Automated implant segmentation in cone-beam CT using edge detection and particle counting

被引:19
|
作者
Pauwels, Ruben [1 ,2 ]
Jacobs, Reinhilde [2 ,3 ]
Bosmans, Hilde [4 ]
Pittayapat, Pisha [1 ,2 ]
Kosalagood, Pasupen [1 ]
Silkosessak, Onanong [1 ]
Panmekiate, Soontra [1 ]
机构
[1] Chulalongkorn Univ, Fac Dent, Dept Radiol, Bangkok, Thailand
[2] Katholieke Univ Leuven, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Oral Imaging Ctr,Fac Med, Leuven, Belgium
[3] Univ Hosp Leuven, Leuven, Belgium
[4] Katholieke Univ Leuven, Dept Imaging & Pathol, Fac Med, Leuven, Belgium
关键词
Cone-beam computed tomography; Computer-assisted image analysis; Dental implants; Radiographic phantom; Dentistry; METAL ARTIFACT REDUCTION; COMPUTED-TOMOGRAPHY; BONE QUALITY; IN-VITRO;
D O I
10.1007/s11548-013-0946-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To develop a fully automated, accurate and robust segmentation technique for dental implants on cone-beam CT (CBCT) images. A head-size cylindrical polymethyl methacrylate phantom was used, containing titanium rods of 5.15 mm diameter. The phantom was scanned on 17 CBCT devices, using a total of 39 exposure protocols. Images were manually thresholded to verify the applicability of adaptive thresholding and to determine a minimum threshold value . A three-step automatic segmentation technique was developed. Firstly, images were pre-thresholded using . Next, edge enhancement was performed by filtering the image with a Sobel operator. The filtered image was thresholded using an iteratively determined fixed threshold and converted to binary. Finally, a particle counting method was used to delineate the rods. The segmented area of the titanium rods was compared to the actual area, which was corrected for phantom tilting. Manual thresholding resulted in large variation in threshold values between CBCTs. After applying the edge-enhancing filter, a stable value of 7.5 % was found. Particle counting successfully detected the rods for all but one device. Deviations between the segmented and real area ranged between 2.7 and + with an average absolute error of . Considering the diameter of the segmented area, submillimeter accuracy was seen for all but two data sets. A segmentation technique was defined which can be applied to CBCT data for an accurate and fully automatic delineation of titanium rods. The technique was validated in vitro and will be further tested and refined on patient data.
引用
收藏
页码:733 / 743
页数:11
相关论文
共 50 条
  • [11] Patient alignment using megavoltage cone-beam CT
    Morin, O.
    Gillis, A.
    Aubin, M.
    Chen, J.
    Mu, G.
    Bocci, K.
    Pouliot, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2280 - 2281
  • [12] Dose calculation using megavoltage cone-beam CT
    Morin, Olivier
    Chen, Josephine
    Aubin, Michele
    Gillis, Amy
    Aubry, Jean-Francois
    Bose, Supratik
    Chen, Hong
    Descovich, Martina
    Xia, Ping
    Pouliot, Jean
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04): : 1201 - 1210
  • [13] Automatic classification and segmentation of multiclass jaw lesions in cone-beam CT using deep learning
    Liu, Wei
    Li, Xiang
    Liu, Chang
    Gao, Ge
    Xiong, Yutao
    Zhu, Tao
    Zeng, Wei
    Guo, Jixiang
    Tang, Wei
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (07)
  • [14] Clinical experience with IGRT using cone-beam CT
    Remeijer, P.
    Sonke, J-J
    Betgen, A.
    de Jong, R.
    Minkema, D.
    van Herk, M.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1774 - 1775
  • [15] Modulation Transfer Function Determination Using the Edge Technique for Cone-beam Micro-CT
    Rong, Junyan
    Liu, Wenlei
    Gao, Peng
    Liao, Qimei
    Lu, Hongbing
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [16] Detection of impurity content in wheat based on cone-beam CT
    Wang, Gangyang
    Zhu, Chunhua
    Wang, Jianhou
    [J]. 2022 IEEE INTERNATIONAL CONFERENCE ON TRUST, SECURITY AND PRIVACY IN COMPUTING AND COMMUNICATIONS, TRUSTCOM, 2022, : 1286 - 1289
  • [17] Detection of Collaterals from Cone-Beam CT Images in Stroke
    Abd Aziz, Azrina
    Izhar, Lila Iznita
    Asirvadam, Vijanth Sagayan
    Tang, Tong Boon
    Ajam, Azimah
    Omar, Zaid
    Muda, Sobri
    [J]. SENSORS, 2021, 21 (23)
  • [18] Particle Path Segmentation: a fast, accurate, and robust method for localization of spherical markers in cone-beam CT projections
    Hakimi, W. E.
    Beutel, J.
    Sakas, G.
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S389 - +
  • [19] Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration
    Kearney, V.
    Gu, X.
    Chen, S.
    Jiang, L.
    Liu, H.
    Chiu, T.
    Yordy, J.
    Nedzi, L.
    Mao, W.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 500 - 500
  • [20] Implant imaging with the I-CAT® cone-beam CT -: a progress report
    Brooks, SL
    Beason, RC
    Sarment, D
    Sukovic, P
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1184 - 1186