Technical principles of dual energy x-ray absorptiometry

被引:172
|
作者
Blake, GM
Fogelman, I
机构
[1] Department of Nuclear Medicine, Guy's Hospital, London SE1 9RT, St Thomas St
关键词
D O I
10.1016/S0001-2998(97)80025-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Since its introduction nearly ten years ago, dual-energy x-ray absorptiometry (DXA) has become the single most widely used technique for performing bone densitometry studies. One reason for its popularity is the ability of DXA systems to measure bone mineral density (BMD) in the spine and proximal femur, the two most common sites for osteoporotic fractures. Other advantages of DXA include the exceptionally low radiation dose to patients, short scan times, high resolution images, good precision and inherent stability of calibration. For these reasons DXA scans are widely used to diagnose osteoporosis, assist making decisions in treatment, and as a follow-up response to therapy. Another important application has been the use of DXA in many clinical trials of new treatments for osteoporosis. Since the first generation pencil beam DXA systems became available, the most significant technical innovation has been the introduction of fan beam systems with shorter scan times, increased patient throughput, and improved image quality. New clinical applications include the measurement of lateral spine and total body BMD, body composition, and vertebral morphometry. Despite these advances, posteroanterior (PA) spine and proximal femur scans remain the most widely used application because of their utility in treatment decisions and monitoring response to therapy. Copyright (C) 1997 by W.B. Saunders Company.
引用
收藏
页码:210 / 228
页数:19
相关论文
共 50 条
  • [1] Technical standardization for dual-energy X-ray absorptiometry
    Leib, E
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (01) : 27 - 36
  • [2] Dual energy X-ray absorptiometry
    Winzenberg, Tania
    Jones, Graeme
    [J]. AUSTRALIAN FAMILY PHYSICIAN, 2011, 40 (1-2) : 43 - 44
  • [3] Dual-energy X-ray absorptiometry
    Braillon, Pierre
    Peretti, Noel
    [J]. NUTRITION CLINIQUE ET METABOLISME, 2011, 25 (02): : 91 - 96
  • [4] Dual-energy X-ray Absorptiometry
    Jain, Rajesh K.
    Vokes, Tamara
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (03) : 291 - 303
  • [5] Single and dual energy X-ray absorptiometry
    J. E. Adams
    [J]. European Radiology, 1997, 7 : S20 - S31
  • [6] Single and dual energy X-ray absorptiometry
    Adams, JE
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (Suppl 2) : S20 - S31
  • [7] Evaluation of peripheral dual energy X-ray absorptiometry: comparison with single photon absorptiometry of the forearm and dual energy X-ray absorptiometry of the spine or femur
    Mole, PA
    McMurdo, MET
    Paterson, CR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (844): : 427 - 432
  • [8] Measuring the structural strength of bones with dual-energy X-ray absorptiometry: principles, technical limitations, and future possibilities
    Thomas Beck
    [J]. Osteoporosis International, 2003, 14 : 81 - 88
  • [10] Current Applications and Selected Technical Details of Dual-Energy X-Ray Absorptiometry
    Sawicki, Piotr
    Talalaj, Marek
    Zycinska, Katarzyna
    Zgliczynski, Wojciech S.
    Wierzba, Waldemar
    [J]. MEDICAL SCIENCE MONITOR, 2021, 27