Instrumenting the small thoracic pedicle: the role of intraoperative computed tomography image-guided surgery

被引:28
|
作者
Jeswani, Sunil [1 ]
Drazin, Doniel [1 ]
Hsieh, Joseph C. [1 ,4 ]
Shweikeh, Faris [1 ]
Friedman, Eric [1 ]
Pashman, Robert [2 ]
Johnson, J. Patrick [1 ,3 ]
Kim, Terrence T. [2 ]
机构
[1] Cedars Sinai Med Ctr, Dept Neurosurg, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Orthopaed, Los Angeles, CA 90048 USA
[3] UC Davis Med Ctr, Dept Neurosurg, Sacramento, CA USA
[4] Univ Texas, Med Sch Houston, Houston, TX USA
关键词
spine instrumentation; thoracic spine; O-arm imaging; intraoperative CT; pedicle screw; ADOLESCENT IDIOPATHIC SCOLIOSIS; SCREW PLACEMENT; IN-VIVO; ACCURACY; NAVIGATION; FLUOROSCOPY; LUMBAR; SAFETY; SPINE;
D O I
10.3171/2014.1.FOCUS13527
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Traditionally, instrumentation of thoracic pedicles has been more difficult because of their relatively smaller size. Thoracic pedicles are at risk for violation during surgical instrumentation, as is commonly seen in patients with scoliosis and in women. The laterally based "in-out-in" approach, which technically results in a lateral breach, is sometimes used in small pedicles to decrease the comparative risk of a medial breach with neurological involvement. In this study the authors evaluated the role of CT image-guided surgery in navigating screws in small thoracic pedicles. Methods. Thoracic (T1-12) pedicle screw placements using the O-arm imaging system (Medtronic Inc.) were evaluated for accuracy with preoperative and postoperative CT. "Small" pedicles were defined as those <= 3 mm in the narrowest diameter orthogonal to the long axis of the pedicle on a trajectory entering the vertebral body on preinstrumentation CT. A subset of "very small" pedicles (<= 2 mm in the narrowest diameter, 13 pedicles) was also analyzed. Screw accuracy was categorized as good (< 1 mm of pedicle breach in any direction or in-out-in screws), fair (1-3 mm of breach), or poor (> 3 mm of breach). Results. Twenty-one consecutive patients (age range 32-71 years) had large (45 screws) and small (52 screws) thoracic pedicles. The median pedicle diameter was 2.5 mm (range 0.9-3 mm) for small and 3.9 mm (3.1-6.7 mm) for large pedicles. Computed tomography-guided surgical navigation led to accurate screw placement in both small (good 100%, fair 0%, poor 0%) and large (good 96.6%, fair 0%, poor 3.4%) pedicles. Good screw placement in very small or small pedicles occurred with an in-out-in trajectory more often than in large pedicles (large 6.8% vs small 36.5%, p < 0.0005; vs very small 69.2%, p < 0.0001). There were no medial breaches even though 75 of the 97 screws were placed in postmenopausal women, traditionally at higher risk for osteoporosis. Conclusions. Computed tomography-guided surgical navigation allows for safe, effective, and accurate instrumentation of small (<= 3 mm) to very small (<= 2 mm) thoracic pedicles.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Megavoltage computed tomography - An emerging tool for image-guided radiotherapy
    Hong, Theodore S.
    Welsh, James S.
    Ritter, Mark A.
    Harari, Paid M.
    Jaradat, Hazim
    Mackie, T. Rockwell
    Mehta, Minesh P.
    [J]. AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2007, 30 (06): : 617 - 623
  • [22] Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing. Part II: Thoracolumbar Spine
    Scheufler, Kai-Michael
    Franke, Joerg
    Eckardt, Anke
    Dohmen, Hildegard
    [J]. NEUROSURGERY, 2011, 69 (06) : 1307 - 1316
  • [23] Image-guided radiation therapy using computed tomography in radiotherapy
    Fung, Winky Wing Ki
    Wu, Vincent Wing Cheung
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2011, 10 (02) : 121 - 136
  • [24] Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing, Part I: Cervicothoracic Spine COMMENTS
    Welch, William C.
    Heary, Robert F.
    [J]. NEUROSURGERY, 2011, 69 (04) : 795 - 795
  • [25] The accuracy of image-guided knee replacement based on computed tomography
    Nabeyama, R
    Matsuda, S
    Miura, H
    Mawatari, T
    Kawano, T
    Iwamoto, Y
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03): : 366 - 371
  • [26] Distortion verification of helical computed tomography for image-guided radiotherapy
    Harada, Takayuki
    Takemura, Akihiro
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22
  • [27] Fluorescence molecular imaging systems for intraoperative image-guided surgery
    Kim, Taehoon
    O'Brien, Connor
    Choi, Hak Soo
    Jeong, Myung Yung
    [J]. APPLIED SPECTROSCOPY REVIEWS, 2018, 53 (2-4) : 349 - 359
  • [28] Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation
    Kim, Terrence T.
    Johnson, J. Patrick
    Pashman, Robert
    Drazin, Doniel
    [J]. BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [29] Image-guided surgery for thoracic ossification of the posterior longitudinal ligament
    Seichi, A
    Takeshita, K
    Kawaguchi, H
    Kawamura, N
    Higashikawa, A
    Nakamura, K
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2005, 3 (02): : 165 - 168
  • [30] Image-guided localization for video-assisted thoracic surgery
    Spirn, PW
    Shah, RM
    Steiner, RM
    Greenfield, AL
    Salazar, AM
    Liu, JB
    [J]. JOURNAL OF THORACIC IMAGING, 1997, 12 (04) : 285 - 292