Instrumenting the small thoracic pedicle: the role of intraoperative computed tomography image-guided surgery

被引:28
|
作者
Jeswani, Sunil [1 ]
Drazin, Doniel [1 ]
Hsieh, Joseph C. [1 ,4 ]
Shweikeh, Faris [1 ]
Friedman, Eric [1 ]
Pashman, Robert [2 ]
Johnson, J. Patrick [1 ,3 ]
Kim, Terrence T. [2 ]
机构
[1] Cedars Sinai Med Ctr, Dept Neurosurg, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Orthopaed, Los Angeles, CA 90048 USA
[3] UC Davis Med Ctr, Dept Neurosurg, Sacramento, CA USA
[4] Univ Texas, Med Sch Houston, Houston, TX USA
关键词
spine instrumentation; thoracic spine; O-arm imaging; intraoperative CT; pedicle screw; ADOLESCENT IDIOPATHIC SCOLIOSIS; SCREW PLACEMENT; IN-VIVO; ACCURACY; NAVIGATION; FLUOROSCOPY; LUMBAR; SAFETY; SPINE;
D O I
10.3171/2014.1.FOCUS13527
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Traditionally, instrumentation of thoracic pedicles has been more difficult because of their relatively smaller size. Thoracic pedicles are at risk for violation during surgical instrumentation, as is commonly seen in patients with scoliosis and in women. The laterally based "in-out-in" approach, which technically results in a lateral breach, is sometimes used in small pedicles to decrease the comparative risk of a medial breach with neurological involvement. In this study the authors evaluated the role of CT image-guided surgery in navigating screws in small thoracic pedicles. Methods. Thoracic (T1-12) pedicle screw placements using the O-arm imaging system (Medtronic Inc.) were evaluated for accuracy with preoperative and postoperative CT. "Small" pedicles were defined as those <= 3 mm in the narrowest diameter orthogonal to the long axis of the pedicle on a trajectory entering the vertebral body on preinstrumentation CT. A subset of "very small" pedicles (<= 2 mm in the narrowest diameter, 13 pedicles) was also analyzed. Screw accuracy was categorized as good (< 1 mm of pedicle breach in any direction or in-out-in screws), fair (1-3 mm of breach), or poor (> 3 mm of breach). Results. Twenty-one consecutive patients (age range 32-71 years) had large (45 screws) and small (52 screws) thoracic pedicles. The median pedicle diameter was 2.5 mm (range 0.9-3 mm) for small and 3.9 mm (3.1-6.7 mm) for large pedicles. Computed tomography-guided surgical navigation led to accurate screw placement in both small (good 100%, fair 0%, poor 0%) and large (good 96.6%, fair 0%, poor 3.4%) pedicles. Good screw placement in very small or small pedicles occurred with an in-out-in trajectory more often than in large pedicles (large 6.8% vs small 36.5%, p < 0.0005; vs very small 69.2%, p < 0.0001). There were no medial breaches even though 75 of the 97 screws were placed in postmenopausal women, traditionally at higher risk for osteoporosis. Conclusions. Computed tomography-guided surgical navigation allows for safe, effective, and accurate instrumentation of small (<= 3 mm) to very small (<= 2 mm) thoracic pedicles.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A prospective study on the use of intraoperative computed tomography (iCT) for image-guided placement of thoracic pedicle screws
    Dinesh, Shree Kumar
    Tiruchelvarayan, Rajendra
    Ng, Ivan
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2012, 26 (06) : 838 - 844
  • [2] Intraoperative computed tomography and automated registration for image-guided cranial surgery
    Eggers, G.
    Kress, B.
    Rohde, S.
    Muehling, J.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (01) : 28 - 33
  • [3] Accuracy of intraoperative computed tomography image-guided surgery in placing pedicle and pelvic screws for primary versus revision spine surgery
    Hsieh, Joseph C.
    Drazin, Doniel
    Firempong, Alexander O.
    Pashman, Robert
    Johnson, J. Patrick
    Kim, Terrence T.
    [J]. NEUROSURGICAL FOCUS, 2014, 36 (03)
  • [4] Elastic Image Fusion Software to Coregister Preoperatively Planned Pedicle Screws With Intraoperative Computed Tomography Data for Image-Guided Spinal Surgery
    Schmidt, Franziska A.
    Mullally, Mary
    Lohmann, Martin
    Hiepe, Patrick
    Kirnaz, Sertac
    Chidambaram, Swathi
    Wipplinger, Christoph
    Hartl, Roger
    [J]. INTERNATIONAL JOURNAL OF SPINE SURGERY, 2021, 15 (02): : 295 - 301
  • [5] Fully automated registration of intraoperative computed tomography image data for image-guided craniofacial surgery
    Eggers, Georg
    Kress, Bodo
    Muehling, Joachim
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (08) : 1754 - 1760
  • [6] Combination of intraoperative computed tomography (CCT) and image-guided neurosurgery
    Koos, WT
    Roessler, K
    Matula, C
    Czech, T
    Schindler, E
    [J]. 11TH INTERNATIONAL CONGRESS OF NEUROLOGICAL SURGERY, VOLS 1 AND 2, 1997, : 1585 - 1590
  • [7] Pediatric Pedicle Screw Placement Using Intraoperative Computed Tomography and 3-Dimensional Image-Guided Navigation
    Larson, A. Noelle
    Santos, Edward R. G.
    Polly, David W., Jr.
    Ledonio, Charles G. T.
    Sembrano, Jonathan N.
    Mielke, Cary H.
    Guidera, Kenneth J.
    [J]. SPINE, 2012, 37 (03) : E188 - E194
  • [8] Image-guided liver surgery: intraoperative projection of computed tomography images utilizing tracked ultrasound
    Kingham, T. Peter
    Scherer, Michael A.
    Neese, Benjamin W.
    Clements, Logan W.
    Stefansic, James D.
    Jarnagin, William R.
    [J]. HPB, 2012, 14 (09) : 594 - +
  • [9] Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery
    Tormenti, Matthew J.
    Kostov, Dean B.
    Gardner, Paul A.
    Kanter, Adam S.
    Spiro, Richard M.
    Okonkwo, David O.
    [J]. NEUROSURGICAL FOCUS, 2010, 28 (03) : 1 - 6
  • [10] Advances in Image-Guided Thoracic Surgery
    Kidane, Biniam
    Yasufuku, Kazuhiro
    [J]. THORACIC SURGERY CLINICS, 2016, 26 (02) : 129 - +