Comparison of the Bishop score, body mass index and transvaginal cervical length in predicting the success of labor induction

被引:37
|
作者
Uyar, Yildiz [1 ]
Erbay, Gurcan [2 ]
Demir, Bilge Cetinkaya [1 ]
Baytur, Yesim [1 ]
机构
[1] Celal Bayar Univ, Fac Med, Dept Obstet & Gynecol, Manisa, Turkey
[2] E Hayri Ustundag Obstet & Gynecol Clin, Izmir, Turkey
关键词
Labor induction; Body mass index; Cervical length; Bishop score; Birth weight; PREINDUCTION SONOGRAPHIC MEASUREMENT; CESAREAN DELIVERY; PROLONGED PREGNANCY; NULLIPAROUS WOMEN; ULTRASOUND; RISK; WEIGHT; COMPLICATIONS; OVERWEIGHT; DURATION;
D O I
10.1007/s00404-008-0915-x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
To evaluate the role of ultrasonographic and various maternal and fetal parameters in predicting successful labor induction. Body mass index, cervical length, dilatation, effacement, Bishop score, parity, maternal age and birth weight were evaluated in 189 singleton pregnant women at 37-42 weeks of gestation and having induction of labor. All underwent induction of labor with oxytocin. Body mass index was calculated using the formula weight (kg)/height(2) (m), cervical measurement was performed by transvaginal ultrasonography and Bishop score was determined by digital examination of cervix. Logistic regression analysis indicated that the cervical length and body mass index were independent variables in determining the risk of cesarean section (OR = 1.206, P = 0.000, CI 95% = 1.117-1.303; OR = 1.223, P = 0.007, CI 95% = 1.058-1.414 respectively). In multiple linear regression analysis, the effect of cervical length and body mass index on induction delivery interval was found to be statistically significant (t = 5.738, P = 0.000; t = 2.680, P = 0.009, respectively). ROC curve showed that the best parameter in predicting the risk of cesarean section was cervical length and that cervical length and body mass index were better parameters compared to the Bishop score (the areas under the curve are 0.819, 0.701 and 0.416, respectively). Body mass index and transvaginal cervical length were better predictors compared to the Bishop score in determining the success of labor induction.
引用
收藏
页码:357 / 362
页数:6
相关论文
共 50 条
  • [41] Comparison between sonographic cervical length and Bishop score in preinduction cervical assessment: a randomized trial
    Park, K. H.
    Kim, S. N.
    Lee, S. Y.
    Jeong, E. H.
    Jung, H. J.
    Oh, K. J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 38 (02) : 198 - 204
  • [42] Transvaginal sonographic assessment of cervical length and wedging for predicting outcome of labor induction at term: a systematic review and meta-analysis
    Verhoeven, C. J. M.
    Opmeer, B. C.
    Oei, S. G.
    Latour, V.
    van der Post, J. A. M.
    Mol, B. W. J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 42 (05) : 500 - 508
  • [43] Comparison of the Bishop score, sonographic measurement of cervical length and fibronectin assay in predicting time to delivery and type of delivery at term
    Rozenberg, P
    Goffinet, F
    Hessabi, M
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 1999, 183 (03): : 589 - 600
  • [44] Predicting success of metabolic surgery: age, body mass index, C-peptide, and duration score
    Lee, Wei-Jei
    Hur, Kyung Yul
    Lakadawala, Muffazal
    Kasama, Kazunori
    Wong, Simon K. H.
    Chen, Shu-Chun
    Lee, Yi-Chih
    Ser, Kong-Han
    SURGERY FOR OBESITY AND RELATED DISEASES, 2013, 9 (03) : 379 - 384
  • [45] Does length of labor vary by maternal body mass index?
    Greenberg, Mara
    Cheng, Yvonne
    Stotland, Naomi
    Caughey, Aaron
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 195 (06) : S106 - S106
  • [46] Transvaginal ultrasonography-measured cervical length versus the modified Bishop score for preinduction cervical assessment at term: A randomised controlled trial
    Okafor, Chigozie G.
    Eleje, George U.
    Ikechebelu, Joseph I.
    Okafor, Chisolum O.
    Nwosu, Betrand O.
    Okafor, Chidinma C.
    Udigwe, Gerald O.
    Mamah, Johnbosco E.
    Ezema, Evaristus C.
    Ogabido, Chukwudi A.
    Obiagwu, Hillary, I
    Okoro, Chukwuemeka C.
    Njoku, Tobechi K.
    Olisa, Chinedu L.
    Okaforcha, Emmanuel, I
    Okonkwo, Ifeanyi O.
    Okafor, Lazarus U.
    Okoye, Kelechi U.
    Nnabuchi, Obinna K.
    Agbanu, Chiemezie M.
    Eke, Ahizechukwu C.
    ULTRASOUND, 2024,
  • [47] Bishop Score vs. ultrasound cervical length in the prediction of cervical ripening success and vaginal delivery in nulliparous women
    Kehila, M.
    Bougmiza, I.
    Ben Hmid, R.
    Abdelfatteh, W.
    Mahjoub, S.
    Channoufi, M. B.
    MINERVA GINECOLOGICA, 2015, 67 (06): : 499 - 505
  • [48] The impact of body mass index on the course of oxytocin labor induction
    Durie, Danielle
    Campbell, Nigel
    Pressman, Eva
    Hackney, David
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2011, 204 : S123 - S123
  • [49] Comparison of sonographic score and Bishop score in the prediction of successful labor induction in term patients: A prospective observational study
    Preethi, R. Udhaya
    Tripathy, Saswati
    CLINICAL EPIDEMIOLOGY AND GLOBAL HEALTH, 2024, 30
  • [50] Interaction between Maternal Obesity and Bishop Score in Predicting Successful Induction of Labor in Term, Nulliparous Patients
    Zelig, Craig M.
    Nichols, Shannon Flood
    Dolinsky, Brad M.
    Hecht, Maximilian W.
    Napolitano, Peter G.
    AMERICAN JOURNAL OF PERINATOLOGY, 2013, 30 (01) : 75 - 80