Quantitative monitoring of BCR-ABL transcript suggestion of a simplified approach considering inaccuracy of measurement and calibration

被引:1
|
作者
Röthlisberger, B
Herklotz, R
Hergersberg, M
Stricker, C
Bargetzi, M
Huber, AR [1 ]
机构
[1] Cantonal Hosp Aarau, Ctr Lab Med, CH-5000 Aarau, Switzerland
[2] Appl Genet Network, Altendorf, Switzerland
[3] Cantonal Hosp Aarau, Dept Hematol Oncol, Aarau, Switzerland
关键词
BCR-ABL; leukemia molecular monitoring; real time quantitative RT-PCR (RQ-PCR); CML;
D O I
10.1080/10428190310001625845
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
According to standard-protocols, real time quantitative RT-PCR (RQ-PCR) for quantification of BCR-ABL fusion transcripts in CML patients is performed with the construction of a standard curve for each run, each sample is analyzed at least in duplicate and 10-40 ml peripheral blood are processed. This approach is appropriate for a research laboratory, but is not suitable for a routine laboratory setting. We show that the calibration curve based on the common 5 dilution standards (between 10 and 10(6) Copies) is strongly influenced by the large variability of the measurements below 100 copies of the gene. In other words, including a standard with 10 copies is a source of error, which cannot be reduced through the construction of a standard curve with each run. Adding additional dilutions between 10 and 100 copies to the standard curve, the variance of the obtained curve is much reduced. As a conclusion, it is unnecessary to construct a calibration curve with each run since only negligible inaccuracy of calibration is added to the inaccuracy of measurement. Running of the samples in duplicate seems unnecessary since the inaccuracy of the method can be correctly estimated. Finally, we propose a standardized collection and isolation of total RNA from only 2.5 ml blood using an integrated system, which allows RNA stabilization for up to 5 days and provides snapshots of BCR-ABL fusion transcripts with higher accuracy than with non-stabilized blood samples.
引用
收藏
页码:1119 / 1121
页数:3
相关论文
共 50 条
  • [1] Quantitative monitoring of BCR-ABL transcript - Suggestion of a simplified approach considering inaccuracy of measurement and calibration.
    Rothlisberger, B
    Herklotz, R
    Hergersberg, M
    Stricker, C
    Andreas, H
    BLOOD, 2003, 102 (11) : 313B - 314B
  • [2] Quantitative assessment of the BCR-ABL transcript using the Cepheid Xpert BCR-ABL monitor assay
    Dufresne, Scott D.
    Belloni, Dorothy R.
    Levy, Norman B.
    Tsongalis, Gregory J.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2007, 131 (06) : 947 - 950
  • [3] Quantitative Monitoring of Mutant BCR-ABL Transcript Levels through Pyrosequencing Analysis
    Zhang, Weisu
    Buccini, Frank
    Weisberger, James
    BLOOD, 2008, 112 (11) : 400 - 401
  • [4] Monitoring BCR-ABL transcript levels by real-time quantitative polymerase chain reaction: a linear regression equation to convert from BCR-ABL/B2M ratio to estimated BCR-ABL/ABL ratio
    Iacobucci, Ilaria
    Galletti, Livia
    Amabile, Marilina
    Soverini, Simona
    Baccarani, Michele
    Martinelli, Giovanni
    HAEMATOLOGICA, 2007, 92 (03) : 429 - 430
  • [5] The role of serial BCR-ABL transcript monitoring in predicting the emergence of BCR-ABL kinase mutations in imatinib-treated patients with chronic myeloid leukemia
    Wang, LH
    Knight, K
    Lucas, C
    Clark, RE
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2006, 91 (02): : 235 - 239
  • [6] Dose modification of imatinib by monitoring the level of BCR-ABL transcript in chronic mvelogenous leukemia
    Ishikawa, Izumi
    Kato, Chiaki
    Harigae, Hideo
    Sugawara, Tomohiro
    Tomiya, Yasuo
    Yamada, Minami
    Ishizawa, Kenichi
    Kameoka, Junichi
    Miyamura, Koichi
    Sasaki, Takeshi
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2006, 210 (04): : 355 - 363
  • [7] Quantitative monitoring of BCR/ABL transcript during STI-571 therapy
    Wu, CJ
    Neuberg, D
    Chillemi, A
    McLaughlin, S
    Hochberg, EP
    Galinsky, I
    Deangelo, D
    Soiffer, RJ
    Alyea, EP
    Capdeville, R
    Stone, RM
    Ritz, J
    LEUKEMIA & LYMPHOMA, 2002, 43 (12) : 2281 - 2289
  • [8] Quantitative monitoring of T3151 BCR-ABL mutation by the invader assay
    Yamamoto, M.
    Kakihana, K.
    Ohashi, K.
    Yamashita, T.
    Akiyama, H.
    Sakamaki, H.
    BONE MARROW TRANSPLANTATION, 2008, 41 : S308 - S308
  • [9] Quantitative intra-individual monitoring of BCR-ABL transcript levels in archival bone marrow trephines of patients with chronic myeloid leukemia
    Bock, O
    Lehmann, U
    Kreipe, H
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2003, 5 (01): : 54 - 60
  • [10] Molecular monitoring of BCR-ABL transcript using Roche lightcycler t(9;22) quantification kit
    Joy, Gary Le Cornec
    Davidson, Peter
    White, Susan
    CHROMOSOME RESEARCH, 2007, 15 : 208 - 208