Posterior meniscal root repair: a biomechanical comparison between human and porcine menisci

被引:3
|
作者
Camarda, L. [1 ]
Bologna, E. [2 ,3 ]
Pavan, D. [1 ]
Morello, F. [1 ]
Monachino, F. [1 ]
Giacco, F. [4 ]
Zingales, M. [2 ,3 ]
机构
[1] Univ Palermo DiChirOnS, Dept Orthopaed Surg, Palermo, Italy
[2] Dipartimento Ingn Civile Ambientale Aerosp Mat DI, Palermo, Italy
[3] Adv Technol Network ATeN Ctr, Bio NanoMech Med Sci Lab, Palermo, Italy
[4] IRCCS Ist Ortoped Galeazzi, Dept Orthopaed Surg, Milan, Italy
来源
关键词
meniscal root repair; meniscal root fixation; suture menisci; porcine menisci; human meniscal root; MEDIAL MENISCUS; TEAR; HEREDITARINESS; AVULSION;
D O I
10.32098/mltj.01.2019.03
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. The aim of the present study was to compare the biomechanical characteristics of posterior meniscal root repair of porcine and human menisci. Methods. In vitro biomechanical testing was performed using 12 porcine menisci and 12 human menisci. All menisci were sectioned at the midpoint of their circumference and mounted on an electro-mechanic testing machine. The posterior root was sutured with three single stitches using a no. 2 non-absorbable suture. All specimens were subjected to cyclic axial loading followed by load-to-failure testing. Displacements were recorded at the conclusion of cycles 1, 100, 500 and 1000. Further, load-displacement curves of each specimen were recorded and analyzed to determine the cyclic stiffness at the 500th and 1000th cycle. Results. A higher elongation of the human specimens was observed after 1, 100, 500 and 1000 loading cycles, when it was compared to porcine specimens (p < 0.05). The total displacement amount of the porcine specimens at the 1000th cycle was 2.2 mm +/- 0.1. Similarly, the total displacement amount of the human specimens at the 1000th cycle was 3 mm +/- 0.5. Higher stiffness was observed in the porcine group at the 500th and 1000th cycle. Conclusion. Three single sutures technique for meniscal root repair appears to be biomechanically effective for both human and porcine menisci.
引用
收藏
页码:76 / 81
页数:6
相关论文
共 50 条
  • [21] Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair
    Lawrence Camarda
    Giuseppe Pitarresi
    Michele Lauria
    Federico Fazzari
    Michele D’Arienzo
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1301 - 1306
  • [22] Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair
    Camarda, Lawrence
    Pitarresi, Giuseppe
    Lauria, Michele
    Fazzari, Federico
    D'Arienzo, Michele
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (09) : 1301 - 1306
  • [23] Biomechanical evaluation of the effect of arthroscopic suture passing instruments on the posterior meniscal root
    Karatekin, Yavuz Selim
    Altinayak, Harun
    Yontar, Onur
    Kehribar, Lokman
    KNEE, 2024, 51 : 93 - 101
  • [24] Outcomes of Medial Meniscal Posterior Root Repair During Proximal Tibial Osteotomy: Is Root Repair Beneficial?
    Lee, Dhong Won
    Lee, Su Hyun
    Kim, Jin Goo
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (09): : 2466 - 2475
  • [25] Biomechanical Comparison Between Suture Anchor and Transtibial Pull-out Repair for Posterior Medial Meniscus Root Tears
    Feucht, Matthias J.
    Grande, Eduardo
    Brunhuber, Johannes
    Rosenstiel, Nikolaus
    Burgkart, Rainer
    Imhoff, Andreas B.
    Braun, Sepp
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (01): : 187 - 193
  • [26] ARTHROSCOPIC TRANSOSSEOUS REPAIR OF A MEDIAL MENISCAL POSTERIOR-ROOT TEAR
    Gannon, Nicholas P.
    Wise, Kelsey L.
    Macalena, Jeffrey A.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2021, 11 (04):
  • [27] Posterior Meniscal Root Repair: The Transtibial Double Tunnel Pullout Technique
    Chahla, Jorge
    Moulton, Samuel G.
    LaPrade, Christopher M.
    Dean, Chase S.
    LaPrade, Robert F.
    ARTHROSCOPY TECHNIQUES, 2016, 5 (02): : E291 - E296
  • [28] Evaluation of meniscal extrusion with posterior root disruption and repair using ultrasound
    Rowland, Grant
    Mar, Damon
    McIff, Terence
    Nelson, Joshua
    KNEE, 2016, 23 (04): : 627 - 630
  • [29] Biomechanical comparison of ultra-high molecular weight polyethylene sutures of different thicknesses of the tensile strength for pullout repair of medial meniscal posterior root tear
    Kakiage, Hibiki
    Handa, Mikiko
    Takahashi, Tsuneari
    Takeshita, Katsushi
    Chikuda, Hirotaka
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (04)
  • [30] Effect of lesion location on fixation strength of the meniscal viper repair system: An in vitro study using porcine menisci
    Chang, HC
    Caborn, DNM
    Nyland, J
    Burden, R
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (04): : 394 - 399