TEMPORAL DEPENDENCE OF THE RADIATION MONITORING INSTRUMENTS FOR AREA MONITORING USED AT RADIODIAGNOSTIC AND INTERVENTION FACILITIES

被引:0
|
作者
Leyton, Fernando [1 ,2 ,3 ]
Macedo, Eric M. [1 ]
Ferreira, Mario J. [1 ,4 ]
Navarro, Valeria C. C. [1 ]
Garcia, Igor F. M. [1 ,5 ]
Pereira, Lara C. S. [1 ]
Navarro, Marcus V. T. [1 ]
机构
[1] Fed Inst Educ Sci & Technol Bahia IFBA, LABPROSAUD, Salvador, BA, Brazil
[2] Diego Port Univ, Fac Hlth & Odontol, Santiago, Chile
[3] Tarapaca Univ, Study Ctr Radiol Sci CECRAD, Arica, Chile
[4] Univ Estadual Bahia, Salvador, BA, Brazil
[5] Bahian Sch Med & Publ Hlth, Salvador, BA, Brazil
关键词
DIAGNOSTIC-RADIOLOGY; SURVEY METERS; CALIBRATION;
D O I
10.1093/rpd/ncv467
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Area monitoring is a fundamental test at radiodiagnostic facilities to maintain an acceptable level of radiation exposure for employees and members of the public. Experimental measurements were taken in an ionising radiation calibration laboratory. Four area monitor instruments were used. Dose and dose rate measurements were measured in integrated and rate operating modes. The results show that precautions are necessary where the area monitor uses exposure times of <= 2 s. When taking measurements in rate mode for times <= 2 s, the area monitors evaluated show a tendency to underestimate dose rate, the inaccuracy was 41 %, and varied between 34 and 45 % for different energies. It is highly recommendable to work in integrated mode, inaccuracy varied from 2 to 35 %. For measurements taken with exposure times of >= 3 s, the average inaccuracy was 15% and the range was between 2 and 41 %.
引用
收藏
页码:509 / 519
页数:11
相关论文
共 50 条
  • [1] PERSONNEL RADIATION MONITORING IN RADIODIAGNOSTIC DEPARTMENT
    BUSHONG, SC
    HARLE, TS
    WRIGHT, AE
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1969, 42 (500): : 632 - &
  • [2] LIMITATIONS OF PERSONAL RADIATION MONITORING IN RADIODIAGNOSTIC DEPARTMENT
    BUCHAN, RCT
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1968, 41 (491): : 876 - &
  • [3] Calibration of radiation protection area monitoring instruments in Sudan
    Suliman, I. I.
    Youssif, B. E.
    Beineen, A. A.
    Hassan, M.
    [J]. RADIATION MEASUREMENTS, 2010, 45 (10) : 1578 - 1581
  • [4] RADIATION MONITORING - METHODS AND INSTRUMENTS .2. MONITORING INSTRUMENTS
    BULLEN, MA
    GARRETT, JA
    [J]. BIOMEDICAL ENGINEERING, 1973, 8 (06): : 250 - 256
  • [5] Neutron radiation area monitoring system for proton therapy facilities
    Newhauser, WD
    Ding, X
    Giragosian, D
    Nill, S
    Titt, U
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 149 - 153
  • [6] RADIATION MONITORING - METHODS AND INSTRUMENTS
    DONALDSO.SP
    [J]. BIOMEDICAL ENGINEERING, 1973, 8 (09): : 406 - 406
  • [7] Latin American and Caribbean intercomparison of radiation protection area monitoring instruments
    Ramos, MMO
    da Cunha, PG
    Suárez, RC
    [J]. RADIATION PROTECTION DOSIMETRY, 2002, 102 (04) : 315 - 322
  • [8] AREA RADIATION MONITORING
    BUCHANAN, H
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1974, 19 (OCT27): : 449 - 449
  • [9] Test instruments for radiation hazard monitoring
    Sathyamurthy, S
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY 2001/02, 2002, : 307 - 310
  • [10] Analysis of calibration results of radiation survey meters used for area monitoring
    Adjei, D.
    Darko, E. O.
    Annkah, J. K.
    Amoako, J. K.
    Ofori, K.
    Emi-Reynolds, G.
    Obeng, M. K.
    Akomaning-Adofo, E.
    Owusu-Manteaw, P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 156 (04) : 506 - 513