Joint motion of bipolar hemiarthroplasty in routine hip functional movements: a dynamic motion study

被引:4
|
作者
Jiang, Weizhou [1 ]
Xiao, Jun [1 ]
Chen, Bin [1 ]
Jia, Ming [2 ]
Zhang, Yang [1 ]
Wang, Jian [1 ]
Shi, Zhanjun [1 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Dept Orthopaed, Guangzhou 510515, Peoples R China
[2] Southern Med Univ, Nanfang Hosp, Dept Radiol, Guangzhou 510515, Peoples R China
关键词
Bipolar hemiarthroplasty; Motion; Inner bearing; Outer bearing; Treadmill; Osteoarthritis; Femoral neck fractures; FEMORAL-NECK FRACTURES; PROSTHESIS; UNIPOLAR; ARTHROPLASTY; ENDOPROSTHESIS; OSTEOLYSIS; COMPONENTS; CONVERSION; MINIMUM;
D O I
10.1186/s12891-020-03749-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundMany motion studies have shown that the inner bearing of bipolar prostheses moves less than expected under non-weight-bearing and static weight-bearing positions, which are not routine functional movements performed postoperatively. The aim of this study was to investigate the behaviours of bipolar prostheses during normal gait and simulative squatting.MethodsThirty-one femoral neck fracture patients were enrolled, and fluoroscopy examinations of walking on a treadmill, simulative squatting, and non-weight-bearing abduction-adduction and flexion-extension motions were performed at an average of 40months postoperatively. The rate of acetabular cartilage degeneration was calculated. The ranges of motion of the outer bearing and inner bearing were determined, and the O/I ratios were calculated. Clinical efficacy was assessed by HHS and EQ-5D score.ResultsThe inner bearing moved more than the outer bearing did, with an O/I ratio of 0.81, during the normal gait examination, while the motion of the outer bearing was obviously dominant during the simulative squatting and non-weight-bearing abduction-adduction and flexion-extension examinations. The mean acetabular cartilage degeneration rate was 0.820.54mm/year at the follow-up. In subgroup analyses, the motion of the outer bearing decreased to some extent with the increase in acetabular wear, and the corresponding O/I ratios among the groups showed a trend of decreasing first and then increasing. The HHS and EQ-5D scores of the patients with osteolysis and femoral stem loosening were much worse than those with fixed implants.Conclusion Bipolar prostheses do function as originally intended during gait, but movement primarily occurs at the outer bearing during other examinations. The motion patterns of bipolar prostheses change with the increase in acetabular wear.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques
    Emami, Mohamad
    Manafi, Alireza
    Hashemi, Behrooz
    Nemati, Ali
    Safari, Saeed
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2013, 1 (01): : 14 - 17
  • [22] FUNCTIONAL RANGES OF MOTION OF THE WRIST JOINT
    RYU, J
    COONEY, WP
    ASKEW, LJ
    AN, KN
    CHAO, EYS
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (03): : 409 - 419
  • [23] A NEW DYNAMIC TESTING APPARATUS TO STUDY GLENOHUMERAL JOINT MOTION
    DEBSKI, RE
    MCMAHON, PJ
    THOMPSON, WO
    WOO, SLY
    WARNER, JJP
    FU, FH
    JOURNAL OF BIOMECHANICS, 1995, 28 (07) : 869 - +
  • [24] Motion correction of head movements in PET: Realisation for routine usage
    Tellmann, L
    Fulton, RR
    Bente, K
    Stangier, I
    Winz, O
    Just, U
    Herzog, H
    Pietrzyk, UK
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3105 - 3107
  • [25] The Large Individual Differences in the Range of Hip Joint Motion Rather Than Lumbar Spine Motion Affect Dynamic Spinopelvic Rhythm
    Yoshioka, Katsuhito
    Murakami, Hideki
    Demura, Satoru
    Kato, Satoshi
    Kawashima, Hiroki
    Sanada, Shigeru
    Tsuchiya, Hiroyuki
    SPINE SURGERY AND RELATED RESEARCH, 2019, 3 (03): : 255 - 260
  • [26] A Study of the Effect of the Femoral Head Diameter on Prosthetic Hip Joint Dislocation Using a Hip-Joint Motion Simulator
    Kiguchi, Kazuo
    Horie, Toru
    Yamashita, Akira
    Ueno, Masaru
    Kobayashi, Tsuneyuki
    Mawatari, Masaaki
    Hotokebuchi, Takao
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 6058 - +
  • [27] A MOTION AND TIME STUDY OF A LIBRARY ROUTINE
    Battles, Dean D.
    Davis, Howard
    Harms, William
    LIBRARY QUARTERLY, 1943, 13 (03): : 241 - 244
  • [28] Evaluation of range of motion restriction within the hip joint
    Glen A. Turley
    Mark A. Williams
    Richard M. Wellings
    Damian R. Griffin
    Medical & Biological Engineering & Computing, 2013, 51 : 467 - 477
  • [29] Synchrony of pelvic and hip joint motion during walking
    Crosbie, J
    Vachalathiti, R
    GAIT & POSTURE, 1997, 6 (03) : 237 - 248
  • [30] Interindividual variations of the hip joint motion in normal gait
    Dujardin, FH
    Roussignol, X
    Mejjad, O
    Weber, J
    Thomine, JM
    GAIT & POSTURE, 1997, 5 (03) : 246 - 250