Derivation of isoeffect dose rate for low-dose-rate brachytherapy and external beam irradiation

被引:2
|
作者
Giap, HB [1 ]
Massullo, V [1 ]
机构
[1] Scripps Clin & Res Fdn, La Jolla, CA 92037 USA
关键词
linear-quadratic model; biological equivalent dose; dose rate effect;
D O I
10.1016/S0360-3016(99)00331-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The combination of external beam irradiation and brachytherapy has been used effectively in the management of many malignancies. Brachytherapy dose is typically prescribed to an isodose rate line, from which the implant duration is derived. In this study, the linear-quadratic model is used to derive the brachytherapy dose rate at which biological effectiveness is equivalent to that of external beam irradiation. Methods and Materials: Relative effectiveness per unit dose (RE) for brachytherapy was based on Dale's formalism, Isoeffect dose rate, defined as the brachytherapy dose rate at which the biological effectiveness is equivalent to that of external beam irradiation, was derived, Results: The functional dependencies of brachytherapy RE on dose rate, alpha/beta ratio, and implant duration were investigated. The isoeffect dose rate depends only on the dose per fraction, sublethal damage repair (SLDR) constant, and the implant duration. The isoeffect dose rate does not depend on alpha/beta ratio. For sufficiently long implant duration >10-15 hours, the value for isoeffect dose rate approaches a constant value around 40 to 50 cGy/hr. Conclusion: The isoeffect dose rate may be useful in treatment planning and optimization for low-dose-rate (LDR) brachytherapy, especially when brachytherapy is used in combination with external beam irradiation. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1355 / 1358
页数:4
相关论文
共 50 条
  • [31] A novel applicator for low-dose-rate brachytherapy of gynecological cancers
    Wolfson, AH
    Wu, X
    Takita, C
    Shao, H
    Luo, C
    Watzich, M
    Diaz, D
    Walker, GR
    Patino-Flynn, VT
    Markoe, AM
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2003, 13 (04) : 532 - 540
  • [32] A novel perineal shield for low-dose-rate prostate brachytherapy
    Weiner, Joseph P.
    Schwartz, David
    Safdieh, Joseph
    Polubarov, Alex
    Telly, Tejas
    Worth, Matthew
    Schreiber, David
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (03) : 197 - 202
  • [33] Low-Dose-Rate Brachytherapy for Prostate Cancer in Low Resource Settings
    Echevarria, M.
    Naghavi, A. O.
    Abuodeh, Y. A.
    Chevere, C. M.
    Yamoah, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E408 - E408
  • [34] Low-dose-rate brachytherapy for low-grade prostate cancer
    Raabe, Nils Kristian
    Normann, Marius
    Lilleby, Wolfgang
    TIDSSKRIFT FOR DEN NORSKE LAEGEFORENING, 2015, 135 (06) : 548 - 552
  • [35] Treatment of roentgenographically occult endobronchial carcinoma with external beam radiotherapy and intraluminal low-dose-rate brachytherapy: Second report
    Saito, M
    Yokoyama, A
    Kurita, Y
    Uematsu, T
    Tsukada, H
    Yamanoi, T
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (03): : 673 - 680
  • [36] External beam radiation therapy and a low-dose-rate brachytherapy boost without or with androgen deprivation therapy for prostate cancer
    Strom, Tobin J.
    Hutchinson, Sean Z.
    Shrinath, Kushagra
    Cruz, Alex A.
    Figura, Nicholas B.
    Nethers, Kevin
    Biagioli, Matthew C.
    Fernandez, Daniel C.
    Heysek, Randy V.
    Wilder, Richard B.
    INTERNATIONAL BRAZ J UROL, 2014, 40 (04): : 474 - 483
  • [37] The American Brachytherapy Society recommendations for low-dose-rate brachytherapy for carcinoma of the cervix
    Nag, S
    Chao, C
    Erickson, B
    Fowler, J
    Gupta, N
    Martinez, A
    Thomadsen, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (01): : 33 - 48
  • [38] High dose rate brachytherapy before external beam irradiation in inoperable oesophageal cancer
    Taal, BG
    Aleman, BMP
    Koning, CCE
    Boot, H
    BRITISH JOURNAL OF CANCER, 1996, 74 (09) : 1452 - 1457
  • [39] Salvage low-dose-rate brachytherapy for locally recurrent prostate cancer after definitive irradiation
    Meraouna, Y.
    Blanchard, P.
    Losa, S.
    Labib, A.
    Krhili, S.
    Pommier, P.
    Crehange, G.
    Flam, T.
    Cosset, J. -m.
    Kissel, M.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 48
  • [40] Local Control and Toxicity of External Beam Reirradiation With a Pulsed Low-dose-rate Technique
    Lee, Charles T.
    Dong, Yanqun
    Li, Tianyu
    Freedman, Samuel
    Anaokar, Jordan
    Galloway, Thomas J.
    Hallman, Mark A.
    Weiss, Stephanie E.
    Hayes, Shelly B.
    Price, Robert A.
    Charlie, C. M.
    Meyer, Joshua E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (04): : 959 - 964