Design of Passive Magnetic Axial Bearing for Seal-less Pump

被引:0
|
作者
Prusa, Radomir [1 ]
Huzlik, Rostislav [1 ]
Haban, Vladimir [1 ]
机构
[1] Brno Univ Technol, Fac Mech Engeneering, Brno, Czech Republic
关键词
electromagnetism; finite element method; magnetism; passive magnetic bearing;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new structure of axial passive magnetic bearing. Conception is based on three rings permanent magnets with axial magnetization and repulsive magnetic forces. The pair of permanent magnets form the bearing stator and central magnet is mounted on the shaft. This axial magnetic bearing is designed to seal-less pump. Analytical calculation of magnetic forces leads to complex equations. Therefore the design has been done for simplify by finite element method in ANSYS Maxwell. Bearing is dimensioned for the forces generated by the pump operation. Passive bearing must work in cooperation with two active radial magnetic bearings for ensure stability in five degrees of freedom. One part of the article is also devoted to experimental measurement.
引用
收藏
页码:72 / 77
页数:6
相关论文
共 50 条
  • [1] AN ADDITION TO THE SEAL-LESS PUMP PAPER
    GAMP, SH
    [J]. CHEMICAL ENGINEERING PROGRESS, 1954, 50 (11) : A8 - A8
  • [2] DESIGN AND DEVELOPMENT OF SEAL-LESS PUMPS
    LITZENBERG, DP
    WHITE, HT
    [J]. CHEMICAL ENGINEERING PROGRESS, 1954, 50 (09) : 436 - 444
  • [3] A SEAL-LESS CENTRIFUGAL PUMP DESIGN FOR THE ELIMINATION OF HEAT-INDUCED THROMBUS FORMATION
    BELENGER, J
    JEANJACQUOT, A
    KNIGHT, CJ
    [J]. ARTIFICIAL ORGANS, 1981, 5 (02) : 193 - 193
  • [4] Seal-less induction motor pump by the use of powdered iron technology
    Kliman, GB
    Johnson, RN
    Saban, D
    [J]. ELECTRIC MACHINES AND POWER SYSTEMS, 2000, 28 (03): : 243 - 250
  • [5] Seal-less MD rheometer
    不详
    [J]. MATERIALS WORLD, 2000, 8 (09) : 8 - 8
  • [7] SEAL-LESS CENTRIFUGAL BLOOD PUMP WITH MAGNETICALLY SUSPENDED ROTOR - ROT-A-FLOT
    MENDLER, N
    PODECHTL, F
    FEIL, G
    HILTMANN, P
    SEBENING, F
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 620 - 624
  • [8] AN IMPLANTABLE SEAL-LESS CENTRIFUGAL PUMP WITH INTEGRATED DOUBLE-DISK MOTOR
    SCHIMA, H
    SCHMALLEGGER, H
    HUBER, L
    BIRGMANN, I
    REINDL, C
    SCHMIDT, C
    ROSCHAL, K
    WIESELTHALER, G
    TRUBEL, W
    LOSERT, U
    WOLNER, E
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 639 - 643
  • [9] A SEAL-LESS CENTRIFUGAL PUMP (BAYLOR GYRO PUMP) FOR APPLICATION TO LONG-TERM CIRCULATORY SUPPORT
    MINATO, N
    SAKUMA, I
    SASAKI, T
    SHIONO, M
    OHARA, Y
    TAKATANI, S
    NOON, GP
    NOSE, Y
    [J]. ARTIFICIAL ORGANS, 1993, 17 (01) : 36 - 42
  • [10] BAYLOR GYRO PUMP - A COMPLETELY SEAL-LESS CENTRIFUGAL PUMP AIMING FOR LONG-TERM CIRCULATORY SUPPORT
    OHARA, Y
    SAKUMA, I
    MAKINOUCHI, K
    DAMM, G
    GLUECK, J
    MIZUGUCHI, K
    NAITO, K
    TASAI, K
    ORIME, Y
    TAKATANI, S
    NOON, GP
    NOSE, Y
    [J]. ARTIFICIAL ORGANS, 1993, 17 (07) : 599 - 604