Lead isotope ratio analysis of bullet samples by using quadrupole ICP-MS

被引:3
|
作者
Tamura, Shu-ichi
Hokura, Akiko
Oishi, Masahiro
Nakai, Izumi
机构
[1] Tokyo Univ Sci, Fac Sci, Dept Appl Chem, Shinjuku Ku, Tokyo 1628601, Japan
[2] TDK Co, Ctr Mat Anal, Ichikawa, Chiba 2728558, Japan
关键词
bullet samples; lead Isotope ratio analysis; forensic identification; quadrupole ICP-MS;
D O I
10.2116/bunsekikagaku.55.827
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement conditions for the precise analysis of the lead stable isotope ratio by using an ICP-MS equipped with a quadrupole mass spectrometer were studied in order to apply the technique to the forensic identification of bullet samples. The values of the relative standard deviation obtained for the ratio of Pb-208/Ph-206, Pb-207/Pb-206 and Pb-204/Pb-206 were lower than 0.2% after optimization of the analytical conditions, including the optimum lead concentration of the sample solution to be about 70 ppb and an integration time for I m/z of 15 s. This method was applied to an analysis of lead in bullets for rifles and handguns; a stable isotope ratio of lead was found to be suitable for the identification of bullets. This study has demonstrated that the lead isotope ratio measured by using a quadrupole ICP-MS was useful for a practical analysis of bullet samples in forensic science.
引用
下载
收藏
页码:827 / 834
页数:8
相关论文
共 50 条
  • [31] LEAD IN ARCHAEOLOGICAL SAMPLES - AN ISOTOPIC STUDY BY ICP-MS
    GHAZI, AM
    APPLIED GEOCHEMISTRY, 1994, 9 (06) : 627 - 636
  • [32] Application of multi-isotope calibration to analysis of wine samples by ICP-MS
    Wheal, Matthew S.
    Wilkes, Eric N.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (11) : 2383 - 2390
  • [33] High precision PU isotope ratio measurements using multicollector ICP-MS
    Croudace, IW
    Warneke, T
    Warwick, PE
    Taylor, RN
    Milton, JA
    ENVIRONMENTAL RADIOCHEMICAL ANALYSIS II, 2003, (291): : 104 - 112
  • [34] Plutonium isotope ratio analysis at femtogram to nanogram levels by multicollector ICP-MS
    Taylor, RN
    Warneke, T
    Milton, JA
    Croudace, IW
    Warwick, PE
    Nesbitt, RW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) : 279 - 284
  • [35] Lead isotope analysis of marine carbonates and seawater by multiple collector ICP-MS
    Reuer, MK
    Boyle, EA
    Grant, BC
    CHEMICAL GEOLOGY, 2003, 200 (1-2) : 137 - 153
  • [36] Application of ICP-MS to the analysis of lead isotope ratios in an ancient bronze mirror
    Matsuoka, N
    Kawamura, H
    Saeki, K
    Koike, M
    Momoshima, N
    Okabe, H
    BUNSEKI KAGAKU, 1996, 45 (02) : 201 - 206
  • [37] Determination of stable lead isotope ratios in environmental samples: Combination of microwave digestion and ICP-MS
    H. Kawamura
    H. Tagomori
    N. Matsuoka
    Y. Takashima
    S. Tawaki
    N. Momoshima
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 242 : 717 - 720
  • [38] Determination of stable lead isotope ratios in environmental samples: Combination of microwave digestion and ICP-MS
    Kawamura, H
    Tagomori, H
    Matsuoka, N
    Takashima, Y
    Tawaki, S
    Momoshima, N
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 242 (03) : 717 - 720
  • [39] Direct Determination of Gold in Rock Samples Using Collision Cell Quadrupole ICP-MS
    Yim, Seong A.
    Choi, Man Sik
    Chae, Jung Sun
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (01) : 171 - 178
  • [40] Lead isotope ratio measurements by ICP-MS: Accuracy, precision, and long-term drift
    Halicz, L
    Erel, Y
    Veron, A
    ATOMIC SPECTROSCOPY, 1996, 17 (05) : 186 - 189