Lead isotope ratio analysis of bullet samples by using quadrupole ICP-MS

被引:3
|
作者
Tamura, Shu-ichi
Hokura, Akiko
Oishi, Masahiro
Nakai, Izumi
机构
[1] Tokyo Univ Sci, Fac Sci, Dept Appl Chem, Shinjuku Ku, Tokyo 1628601, Japan
[2] TDK Co, Ctr Mat Anal, Ichikawa, Chiba 2728558, Japan
关键词
bullet samples; lead Isotope ratio analysis; forensic identification; quadrupole ICP-MS;
D O I
10.2116/bunsekikagaku.55.827
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement conditions for the precise analysis of the lead stable isotope ratio by using an ICP-MS equipped with a quadrupole mass spectrometer were studied in order to apply the technique to the forensic identification of bullet samples. The values of the relative standard deviation obtained for the ratio of Pb-208/Ph-206, Pb-207/Pb-206 and Pb-204/Pb-206 were lower than 0.2% after optimization of the analytical conditions, including the optimum lead concentration of the sample solution to be about 70 ppb and an integration time for I m/z of 15 s. This method was applied to an analysis of lead in bullets for rifles and handguns; a stable isotope ratio of lead was found to be suitable for the identification of bullets. This study has demonstrated that the lead isotope ratio measured by using a quadrupole ICP-MS was useful for a practical analysis of bullet samples in forensic science.
引用
下载
收藏
页码:827 / 834
页数:8
相关论文
共 50 条
  • [1] A method for increasing the precision of isotope ratio analysis on a Quadrupole ICP-MS based on measurements of lead and strontium
    Dronov, Michail
    Schram, Juergen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (11) : 1796 - 1803
  • [2] Lead isotope measurements on aerosol samples with ICP-MS
    Widmer, CR
    Krähenbühl, U
    Kramers, J
    Tobler, L
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (02): : 171 - 173
  • [3] Lead isotope measurements on aerosol samples with ICP-MS
    C. R. Widmer
    U. Krähenbühl
    J. Kramers
    L. Tobler
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 171 - 173
  • [4] Determination of lead isotopes ratio in rock samples by ICP-MS
    Zheng, Pei-Xi
    Zhou, Yan
    Wang, Tie-Fu
    Liu, Li
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A1522 - A1522
  • [5] Multicollector ICP-MS for isotope ratio analysis of uranium
    Hart, Garret
    Pratt, Sandra
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [6] Long-Term Observations of Isotope Ratio Accuracy and Reproducibility Using Quadrupole ICP-MS
    Ulrich, Thomas
    Kamber, Balz S.
    Woodhead, Jon D.
    Spencer, Lizzy A.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2010, 34 (02) : 161 - 174
  • [7] Determination of Lead Isotope Ratios in Bullet Samples for Forensic Purpose by Single Collector High-resolution ICP-MS
    Shimamura, Yoshinori
    Nakai, Izumi
    BUNSEKI KAGAKU, 2013, 62 (09) : 765 - 774
  • [8] Optimization of lithium isotope analysis in geological materials by quadrupole ICP-MS
    Liu, Xiao-Ming
    Li, Wenshuai
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (08) : 1708 - 1717
  • [9] SOME APPLICATIONS OF ISOTOPE ANALYSIS OF LEAD IN FOOD BY ICP-MS
    CREWS, HM
    MASSEY, RC
    MCWEENY, DJ
    DEAN, JR
    EBDON, L
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03): : 464 - 466
  • [10] Some applications of isotope analysis of lead in food by ICP-MS
    Crews, H.M.
    Massey, R.C.
    McWeeny, D.J.
    Dean, J.R.
    Ebdon, L.
    Journal of Research of the National Bureau of Standards (United States), 1988, 93 (03): : 464 - 466