Dual-Mode Intracranial Catheter Integrating 3D Ultrasound Imaging and Hyperthermia for Neuro-oncology: Feasibility Study

被引:13
|
作者
Herickhoff, Carl D. [1 ]
Light, Edward D. [1 ]
Bing, Kristin F. [1 ]
Mukundan, Srinivasan [2 ]
Grant, Gerald A. [3 ]
Wolf, Patrick D. [1 ]
Smith, Stephen W. [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[3] Duke Univ, Med Ctr, Div Neurosurg, Durham, NC 27708 USA
关键词
Catheter transducer; dual-mode array; real-time 3D imaging; ultrasound hyperthermia; BLOOD-BRAIN-BARRIER; DURAL SINUS THROMBOSIS; REAL-TIME; FOCUSED ULTRASOUND; RHEOLYTIC THROMBECTOMY; ENDOVASCULAR TREATMENT; ARRAY; DISRUPTION; SYSTEM; TRANSDUCER;
D O I
10.1177/016173460903100201
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this study, we investigated the feasibility of an intracranial catheter transducer with dual-mode capability of real-time 3D (RT3D) imaging and ultrasound hyperthermia, for application in the visualization and treatment of tumors in the brain. Feasibility is demonstrated in two ways: first by using a 50-element linear array transducer (17 mm x 3.1 mm aperture) operating at 4.4 MHz with our Volumetrics diagnostic scanner and custom, electrical impedance-matching circuits to achieve a temperature rise over 4 degrees C in excised pork muscle, and second, by designing and constructing a 12 Fr, integrated matrix and linear-array catheter transducer prototype for combined RT3D imaging and heating capability. This dual-mode catheter incorporated 153 matrix array elements and I I linear array elements diced on a 0.2 mm pitch, with a total aperture size of 8.4 mm x 2.3 mm. This 3.64 MHz array achieved a 3.5 degrees C in vitro temperature rise at a 2 cm focal distance in tissue-mimicking material. The dual-mode catheter prototype was compared with a Siemens 10 Fr AcuNav (TM) catheter as a gold standard in experiments assessing image quality and therapeutic potential and both probes were used in an in vivo canine brain model to image anatomical structures and color Doppler blood flow and to attempt in vivo heating.
引用
收藏
页码:81 / 100
页数:20
相关论文
共 50 条
  • [21] 3D Specimen Scanning and Mapping in Musculoskeletal Oncology: A Feasibility Study
    Colazo, Juan M.
    Prasad, Kavita
    Miller, Alexis
    Sharif, Kayvon
    Aweeda, Marina
    Fassler, Carly
    Singh, Reena
    Schwartz, Herbert S.
    Lawrenz, Joshua M.
    Holt, Ginger E.
    Topf, Michael C.
    ANNALS OF SURGICAL ONCOLOGY, 2024, 31 (03) : 2051 - 2060
  • [22] 3D Specimen Scanning and Mapping in Musculoskeletal Oncology: A Feasibility Study
    Juan M. Colazo
    Kavita Prasad
    Alexis Miller
    Kayvon Sharif
    Marina Aweeda
    Carly Fassler
    Reena Singh
    Herbert S. Schwartz
    Joshua M. Lawrenz
    Ginger E. Holt
    Michael C. Topf
    Annals of Surgical Oncology, 2024, 31 : 2051 - 2060
  • [23] Effect of bevacizumab on refractory meningiomas: 3D volumetric growth rate versus response assessment in neuro-oncology criteria
    Borenstein, Sara Faye
    Eliyahu, Ruth
    Amiel, Alexandra
    Talianski, Alisa
    Ofer, Jonathan
    Even-Haim, Shaked
    Kanner, Andrew
    Laviv, Yosef
    Limon, Dror
    Siegal, Tali
    Yust-Katz, Shlomit
    NEURO-ONCOLOGY ADVANCES, 2024, 6 (01)
  • [25] Dual-Band Bandpass Filters Using 3D Printed Dual-Mode Nested Spherical Resonators
    Liu, Jiawei
    Psychogiou, Dimitra
    IEEE ACCESS, 2024, 12 : 64439 - 64445
  • [26] 3D ultrasound navigation in syrinx surgery - a feasibility study - Comment
    Unsgaard, G
    ACTA NEUROCHIRURGICA, 2005, 147 (05) : 540 - 541
  • [27] Iterative neuronavigation using 3D ultrasound. A feasibility study
    Trantakis, C
    Meixensberger, J
    Lindner, D
    Strauss, G
    Grunst, G
    Schmidtgen, A
    Arnold, S
    NEUROLOGICAL RESEARCH, 2002, 24 (07) : 666 - 670
  • [28] On the design of a Dual-Mode User Interface for accessing 3D content on the World Wide Web
    Jankowski, Jacek
    Decker, Stefan
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER STUDIES, 2013, 71 (7-8) : 838 - 857
  • [29] Broadband Dual-Mode HIFU Array for Therapy Monitoring and 3D Target Motion Estimation
    Kaczkowski, Peter J.
    Morrison, Kyle P.
    Keilman, George W.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [30] Dual-mode 3D printed dynamic wrist driven orthosis for hand therapy exercises
    Risangtuni, Ayu Gareta
    Suprijanto, S.
    Nazaruddin, Yul Yunazwin
    Mahyuddin, Andi I.
    FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2023, 9