The application of thermoluminescence dosimetry in X-ray energy discrimination

被引:9
|
作者
Nelson, V. K. [1 ]
Holloway, L. [1 ,2 ,3 ]
McLean, I. D. [4 ]
机构
[1] Liverpool & Macarthur Canc Therapy Ctr, Campbelltown, NSW 2560, Australia
[2] Univ Sydney, Inst Med Phys, Sydney, NSW 2000, Australia
[3] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2560, Australia
[4] Canberra Hosp, Dept Med Phys, Garran, ACT 2605, Australia
关键词
Thermoluminescence dosimetry; X-ray energy estimation; Personal dosimetry; Dosimetry intercomparisons; QUALITY-ASSURANCE; TL DOSIMETERS; FIELD EDGE; PHOTON; DEPENDENCE; DETECTORS; BEAM;
D O I
10.1007/s13246-015-0374-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Clinical dosimetry requires an understanding of radiation energy to accurately determine the delivered dose. For many situations this is known, however there are also many situations where the radiation energy is not well known, thus limiting dosimetric accuracy. This is the case in personnel dosimetry where thermo luminescent (TL) dosimetry is the method of choice. Traditionally beam energy characteristics in personnel dosimetry are determined through discrimination with the use of various filters fitted within a radiation monitor. The presence of scattered and characteristic radiation produced by these metallic filters, however, can compromise the results. In this study the TL response of five materials TLD100, TLD100H, TLD200, TLD400 and TLD500, was measured at various X-ray energies. The TL sensitivity ratio for various combinations of materials as a function of X-ray energy was calculated. The results indicate that in personal dosimetry a combination of three or more TL detector system has a better accuracy of estimation of effective radiation energy of an X-ray beam than some of the current method of employed for energy estimation and has the potential to improve the accuracy in dose determination in a variety of practical situations. The development of this method also has application in other fields including quality assurance of the orthovoltage therapy machines, dosimetry intercomparisons of kilovoltage X-ray beams, and measurement of the dose to critical organs outside a treatment field of a megavoltage therapy beam.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [41] Thermoluminescence investigations in X-ray irradiated CaS phosphor
    Adhikary, S.
    Choubey, A.
    Das, S.
    Sharma, S. K.
    Manam, J.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2010, 489 (01) : 4 - 8
  • [42] Comparison of X-ray Beam Energy Spectrum and Effective Energy in Small Animal Imaging and Dosimetry
    Hamdi, Mahdjoub
    Mimi, Malika
    Bentourkia, M'hamed
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [43] Superficial and orthovoltage x-ray beam dosimetry
    Podgorsak, EB
    Gosselin, M
    Evans, MDC
    MEDICAL PHYSICS, 1998, 25 (07) : 1206 - 1211
  • [44] Dosimetry for a monochromatic X-ray source, the CXS
    Norman, A
    Iwamoto, K
    Solberg, T
    Landahl, E
    Luhmann, N
    MEDICAL PHYSICS, 2002, 29 (06) : 1249 - 1249
  • [45] Material discrimination by high-energy x-ray dual-energy imaging
    Wang Xue-Wu
    Li Jian-Min
    Kang Ke-Jun
    Tang Chuan-Xiang
    Mang Li
    Chen Zhi-Qiang
    Li Yuan-Jing
    Zhong Hua-Qiang
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2007, 31 (11): : 1076 - 1081
  • [46] 4 MEV X-RAY FILM DOSIMETRY
    JACOBSON, A
    RADIOLOGY, 1972, 103 (03) : 703 - &
  • [47] Fluorescent Nanogel Sensors for X-ray Dosimetry
    Jiang, Li
    Li, Wenxiang
    Nie, Jing
    Wang, Rensheng
    Chen, Xinjian
    Fan, Wenhui
    Hu, Liang
    ACS SENSORS, 2021, 6 (04) : 1643 - 1648
  • [49] Advances in kilovoltage x-ray beam dosimetry
    Hill, Robin
    Healy, Brendan
    Holloway, Lois
    Kuncic, Zdenka
    Thwaites, David
    Baldock, Clive
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (06): : R183 - R231
  • [50] MOSFET dosimetry of an X-ray microbeam.
    Rosenfeld, AB
    Kaplan, GI
    Kron, T
    Allen, BJ
    Dilmanian, A
    Orion, I
    Ren, B
    Lerch, MLF
    Holmes-Siedle, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 1774 - 1780