Distal Radius Volar Locking Plate Design and Associated Vulnerability of the Flexor Pollicis Longus

被引:49
|
作者
Limthongthang, Roongsak [1 ]
Bachoura, Abdo
Jacoby, Sidney M.
Osterman, A. Lee
机构
[1] Mahidol Univ, Dept Orthopaed Surg, Fac Med, Siriraj Hosp, Bangkok 10700, Thailand
来源
关键词
Distal radius fracture; flexor tendon rupture; plate prominence; volar plating; watershed line; TENDON RUPTURES; FRACTURE; FIXATION; PLACEMENT;
D O I
10.1016/j.jhsa.2014.01.038
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Flexor pollicis longus (FPL) tendon rupture is a well-documented complication related to the use of distal radius volar locking plates (VLPs). The final common pathway of flexor tendon rupture appears to involve implants prominent at the watershed line. We hypothesized that significant differences in VLP prominence exist between various plate designs. Methods Ten fresh frozen specimens were dissected to identify the path of the FPL in relationship to the distal radius at the watershed line. Five VLP designs were fixed to each specimen based on their anatomic fit, and slid distally until the distal edge of the plate reached the watershed line. The position of each fixed plate was evaluated by fluoroscopy. We used a 3-dimensional laser scanner to create computer models. The total surface area of plate prominence volar to the watershed line and the prominent area beneath the FPL were measured in the axial plane using computer software. Results At the watershed line, the FPL was located at 54% of the maximal width of the radius, as measured from its volar-ulnar comer. There were no significant differences in the location of plate fixation on lateral view radiographs according to the classification of Soong et al. The mean total surface area of plate prominence was 36 mm(2). The mean prominent area beneath the FPL was 10 mm(2). Significant differences in plate prominence were noted for various designs. Conclusions Despite optimal plate placement, various VLP designs were observed to have prominent profiles volar to the watershed line, to varying extents. Copyright (C) 2014 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:852 / 860
页数:9
相关论文
共 50 条
  • [11] Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius
    Bell, JSP
    Wollstein, R
    Citron, ND
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02): : 225 - 226
  • [12] Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the π plate on the volar surface of the distal radius
    Nunley, JA
    Rowan, PR
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1999, 24A (06): : 1279 - 1280
  • [13] Ultrasonographic movement of the flexor pollicis longus tendon before and after removal of a volar plate for the distal radius fracture
    Nanno, Mitsuhiko
    Kodera, Norie
    Tomori, Yuji
    Takai, Shinro
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (01):
  • [14] DELAYED RUPTURE OF FLEXOR POLLICIS LONGUS TENDON AFTER VOLAR PLATING OF THE DISTAL RADIUS
    Koo, Siu Cheong
    Ho, Sheung Tung
    [J]. JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2006, 11 (1-2): : 67 - 70
  • [15] Delayed Rupture of Flexor Pollicis Longus after Volar Plating for a Distal Radius Fracture
    Cho, Chul-Hyun
    Lee, Kyung-Jae
    Song, Kwang-Soon
    Bae, Ki-Cheor
    [J]. CLINICS IN ORTHOPEDIC SURGERY, 2012, 4 (04) : 325 - 328
  • [16] Flexor Pollicis Longus Tendon Rupture after Volar Plating of a Distal Radius Fracture
    Lifchez, Scott D.
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 125 (01) : 21E - 23E
  • [17] Ultrasonographic evaluation of contact configuration between flexor pollicis longus tendon and the volar prominence of volar plate in patients with distal radius fracture
    Kim, Jae Kwang
    Shin, Young Ho
    Kim, Minsoo
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (02) : 1103 - 1108
  • [18] Ultrasonographic evaluation of contact configuration between flexor pollicis longus tendon and the volar prominence of volar plate in patients with distal radius fracture
    Jae Kwang Kim
    Young Ho Shin
    Minsoo Kim
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 1103 - 1108
  • [19] Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
    Lv, Yang-Xun
    Chen, Mang-Mang
    Su, Chen-Xian
    Ye, Hao-Nan
    Yang, Jie
    Li, Jing
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (08)
  • [20] Rupture of the Flexor Pollicis Longus Tendon Involved between the Radial Shaft and the Volar Locking Plate
    Hiraishi, Yuri
    Kimura, Hiroo
    Suzuki, Taku
    Matsumura, Noboru
    Iwamoto, Takuji
    Matsumoto, Morio
    Nakamura, Masaya
    [J]. JOURNAL OF WRIST SURGERY, 2023, 12 (06) : 540 - 542