The feasibility and accuracy of ultrasound assessment in the labor room

被引:15
|
作者
Usman, S. [1 ,2 ]
Wilkinson, M. [2 ]
Barton, H. [2 ]
Lees, C. C. [1 ,2 ]
机构
[1] Imperial Coll Healthcare NHS Trust, London, England
[2] Imperial Coll London, Inst Reprod Dev Biol, London, England
来源
关键词
Transperineal; fetal position; head perineum distance; caput; cervical dilatation; partogram; FETAL HEAD POSITION; TRANSVAGINAL DIGITAL EXAMINATION; TRANSPERINEAL ULTRASOUND; TRANSABDOMINAL ULTRASOUND; CERVICAL DILATATION; PRELABOR RUPTURE; MEMBRANES; STATION; PREGNANCIES; PREDICTION;
D O I
10.1080/14767058.2018.1465553
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Vaginal examination is widely used to assess the progress of labor; however, it is subjective and poorly reproducible. We aim to assess the feasibility and accuracy of transabdominal and transperineal ultrasound compared to vaginal examination in the assessment of labor and its progress. Methods: Women were recruited as they presented for assessment of labor to a tertiary inner city maternity service. Paired vaginal and ultrasound assessments were performed in 192 women at 24-42 weeks. Fetal head position was assessed by transabdominal ultrasound defined in relation to the occiput position transformed to a 12-hour clock face; fetal head station defined as head-perineum distance by transperineal ultrasound; cervical dilatation by anterior to posterior cervical rim measurement and caput succedaneum by skin-skull distance on transperineal ultrasound. Results: Fetal head position was recorded in 99.7% (298/299) of US and 51.5% (154/299) on vaginal examination (p < .0001(1)). Bland-Altman analysis showed 95% limits of agreement, -5.31 to 4.84 clock hours. Head station was recorded in 96.3% (308/320) on vaginal examination (VE) and 95.9% (307/320) on US (p = .79(1)). Head station and head perineum distance were negatively correlated (Spearman's r = -.57, p < .0001). 54.4% (178/327) of cervical dilatation measurements were determined using US and 100% on VE/speculum (p < .0001). Bland-Altman analysis showed 95% limits of agreement -2.51-2.16 cm. The presence of caput could be assessed in 98.4% (315/320) of US and was commented in 95.3% (305/320) of VEs, with agreement for the presence of caput of 76% (p < .05). Fetuses with caput greater than 10 mm had significantly lower head station (p < .0001). Conclusions: We describe comprehensive ultrasound assessments in the labor room that could be translated to the assessment of women in labor. Fetal head position is unreliably determined by vaginal examination and agrees poorly with US. Head perineum distance has a moderate correlation with fetal head station in relation to the ischial spines based on vaginal examination. Cervical dilatation is not reliably assessed by ultrasound except at dilatations of less than 4 cm. Caput is readily quantifiable by ultrasound and its presence is associated with lower fetal head station. Transabdominal and transperineal ultrasound is feasible in the labor room with an accuracy that is generally greater than vaginal examinations.
引用
收藏
页码:3442 / 3451
页数:10
相关论文
共 50 条
  • [41] Satellite radar interferometry for deformation monitoring: a priori assessment of feasibility and accuracy
    Hanssen, RF
    [J]. INTERNATIONAL JOURNAL OF APPLIED EARTH OBSERVATION AND GEOINFORMATION, 2005, 6 (3-4): : 253 - 260
  • [42] Accuracy of unguided and ultrasound guided Coracohumeral ligament infiltrations - a feasibility cadaveric case series
    Pape, John L.
    Boudier-Reveret, Mathieu
    Brismee, Jean-Michel
    Gilbert, Kerry K.
    Grabs, Detlev
    Sobczak, Stephane
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [43] Three dimensional ultrasound reconstruction of left atrium anatomy: feasibility and accuracy of a novel method
    Asbach, S.
    Biermann, J.
    Jacques, B.
    Bode, C.
    Faber, T.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 558 - 559
  • [44] Ultrasound-Guided Procedures in Rheumatology Daily Practice Feasibility, Accuracy, and Safety Issues
    Cipolletta, Edoardo
    Filippucci, Emilio
    Incorvaia, Antonella
    Schettino, Martina
    Smerilli, Gianluca
    Di Battista, Jacopo
    Tesei, Giulia
    Cosatti, Micaela Ana
    Di Donato, Eleonora
    Tardella, Marika
    Di Matteo, Andrea
    Di Carlo, Marco
    Grassi, Walter
    [J]. JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2021, 27 (06) : 226 - 231
  • [45] Point-of-care transperineal ultrasound for assessment of cervical dilation in labor
    Connell, Phillip
    Turrentine, Mark
    Antoniewicz, Leah
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S559 - S560
  • [46] Pre-Induction Transperineal Ultrasound Assessment for the Prediction of Labor Outcome
    Chan, Winnie W. Y.
    Chaemsaithong, Piya
    Lim, Wen Teng
    Tse, Ada W. T.
    Kwan, Angel H. W.
    Leung, Tak Yeung
    Sahota, Daljit S.
    Poon, Liona C.
    [J]. FETAL DIAGNOSIS AND THERAPY, 2019, 45 (04) : 256 - 267
  • [47] Accuracy of unguided and ultrasound guided Coracohumeral ligament infiltrations – a feasibility cadaveric case series
    John L. Pape
    Mathieu Boudier-Revéret
    Jean-Michel Brismée
    Kerry K. Gilbert
    Detlev Grabs
    Stéphane Sobczak
    [J]. BMC Musculoskeletal Disorders, 21
  • [48] Digital and transvaginal ultrasound cervical assessment for prediction of successful labor induction
    Tanir, H. M.
    Sener, T.
    Yildiz, Z.
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2008, 100 (01) : 52 - 55
  • [49] QUANTITATIVE ULTRASOUND ASSESSMENT OF THE FACET JOINT IN THE LUMBAR SPINE: A FEASIBILITY STUDY
    Liu, Da
    Huang, Ying
    Tian, Dan
    Yin, Jing
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05): : 1226 - 1232
  • [50] Ultrasound Assessment of Umbilical Cord Morphology in the First Trimester: A Feasibility Study
    Narayan, Rajit
    Saaid, Rahmah
    Pedersen, Lars
    Hyett, Jon
    [J]. FETAL DIAGNOSIS AND THERAPY, 2015, 38 (03) : 212 - 217