Toward a Large RF Ion Source for the ITER Neutral Beam Injector: Overview of the ELISE Test Facility and First Results

被引:15
|
作者
Nocentini, Riccardo [1 ]
Fantz, Ursel [1 ]
Franzen, Peter [1 ]
Froeschle, Markus [1 ]
Heinemann, Bernd [1 ]
Riedl, Rudolf [1 ]
机构
[1] Max Planck Inst Plasma Phys, D-85748 Garching, Germany
关键词
Extraction from a large ion source experiment (ELISE); ITER; negative ion source; neutral beam injection; radio frequency (RF); source;
D O I
10.1109/TPS.2013.2293607
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The ion source test facility extraction from a large ion source experiment (ELISE) has recently been built at Max Planck Institute for Plasma Physics (IPP) Garching (Germany) and has been operational since December 2012. ELISE is an important intermediate step in the R&D roadmap that the European domestic agency Fusion for Energy has defined for the International Thermonuclear Experimental Reactor (ITER) neutral beam injectors. This new test facility for a large radio frequency ion source builds up on the experience gained during many years of successful operation of smaller testbeds at IPP. The purpose of ELISE is to extract a negative ion beam, at ITER relevant parameters, using an ion source with the full width (1 m) and half the height of the ITER source. ELISE is designed to generate plasma for up to 1 h and extract a H- or D- beam at up to 60 kV. Available power supplies allow beam pulses of 10 s every 150-180 s. Although ELISE is designed to be as close as possible to the ITER source, technical solutions have been implemented that allow considerable experimental flexibility. Focus was put on easier diagnostic access and ease of maintenance. The results gained during the construction and operation of ELISE are delivering very important information to support the design and operation of the neutral beam test facility PRIMA to be built in Padua (Italy). This paper gives an overview of the project, presents experiences made during commissioning, and shows some basic results obtained so far.
引用
收藏
页码:616 / 623
页数:8
相关论文
共 50 条
  • [21] Development and first results of large area radio frequency plasma source for EAST neutral beam injector
    Xie, Yahong
    Hu, Chundong
    Jiang, Caichao
    Wei, Jianglong
    Gu, Yuming
    Cui, Qinlong
    Xu, Yongjian
    Liang, Lizhen
    Chen, Shiyong
    Xie, Yuanlai
    FUSION ENGINEERING AND DESIGN, 2019, 138 : 24 - 26
  • [22] Improvement of a large negative ion source for the Large Helical Device neutral beam injector
    Takeiri, Y
    Ikeda, K
    Hamabe, M
    Osakabe, M
    Kaneko, O
    Oka, Y
    Tsumori, K
    Asano, E
    Kawamoto, T
    Sato, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 1087 - 1089
  • [23] Detailed design of the RF source for the 1 MV neutral beam test facility
    Marcuzzi, D.
    Dalla Palma, M.
    Pavei, M.
    Heinemann, B.
    Kraus, W.
    Riedl, R.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1253 - 1258
  • [24] Progress of the development of the IPP RF negative ion source for the ITER neutral beam system
    Franzen, P.
    Falter, H. D.
    Fantz, U.
    Kraus, W.
    Berger, M.
    Christ-Koch, S.
    Froeschle, M.
    Gutser, R.
    Heinemann, B.
    Hilbert, S.
    Leyer, S.
    Martens, C.
    McNeely, P.
    Riedl, R.
    Speth, E.
    Wuenderlich, D.
    NUCLEAR FUSION, 2007, 47 (04) : 264 - 270
  • [25] Design of a cooling system for the ITER Ion Source and Neutral Beam test facilities
    Dalla Palma, M.
    Dal Bello, S.
    Fellin, F.
    Zaccaria, P.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1460 - 1464
  • [26] Upgrade and experimental results of radio frequency ion source for neutral beam injector
    Xie, Yahong
    Hu, Chundong
    Jiang, Caichao
    Gu, Yuming
    Xu, Yongjian
    Chen, Shiyong
    Liang, Lizhen
    Liu, Zhimin
    Xie, Yuanlai
    FUSION ENGINEERING AND DESIGN, 2017, 114 : 72 - 75
  • [27] Plasma homogeneity over the extraction beamlet groups at the half size ITER negative ion source at ELISE test facility
    Yordanov, D.
    Wunderlich, D.
    Wimmer, C.
    Riedl, R.
    Navarro, A.
    Fantz, U.
    20TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2024, 2743
  • [28] Performance Test Results of Ion Beam Transport for SST-1 Neutral Beam Injector
    Jana, M. R.
    Mattoo, S. K.
    Uhlemann, R.
    23RD NATIONAL SYMPOSIUM ON PLASMA SCIENCE AND TECHNOLOGY (PLASMA-2008), 2010, 208
  • [29] Analysis and Experimental Study of Impedance Matching Characteristic of RF Ion Source on Neutral Beam Injector
    Jiang, Caichao
    Hu, Chundong
    Xie, Yahong
    Chen, Shiyong
    Cui, Qinglong
    Xie, Yuanlai
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (07) : 2677 - 2679
  • [30] Experimental Results of Ion Beam Extraction of High-Current Ion Source for EAST Neutral Beam Injector
    Xie, Ya Hong
    Hu, Chun Dong
    Liu, Sheng
    Jiang, Cai Chao
    Liang, Li Zhen
    Xu, Yong Jian
    Li, Jun
    Xie, Yuan Lai
    Shen, Peng
    Liu, Zhi Min
    JOURNAL OF FUSION ENERGY, 2013, 32 (04) : 513 - 517