Investigating control strategies for a domestic low-temperature heat pump heating system

被引:21
|
作者
Sakellari, D. [1 ]
Forsen, M. [1 ]
Lundqvist, P. [1 ]
机构
[1] Royal Inst Technol, Dept Energy Technol, Div Appl Thermodynam & Refrigerat, S-10044 Stockholm, Sweden
关键词
heat pump; domestic application; heating; floor; modelling; regulation; automatic;
D O I
10.1016/j.ijrefrig.2005.10.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
Despite energy conservation regulations and efforts for improving HVAC operations, numerous domestic buildings do not perform energy efficiently and many times the indoor environment is far away from specified comfort levels. Especially in houses served from low-temperature heating systems the low ability of the heating system to respond to fast changing thermal loads is common. In such cases, the implementation of new, sophisticated controls is an important issue. In this study, we use a reference model of a domestic low temperature heat pump heating system developed in TRNSYS-EES and analyse its operation. Several methods of control strategies have been applied for specified time periods in order to keep the comfort within reasonable ranges. Prognostic climatic control and increased ventilation rates when required are some of these methods. The results depict the influence of the control method on the indoor temperature and the comfort indexes of PMV and PPD. The highest indoor temperature difference for a chosen day reaches 4 degrees C when there is no shading and when there is internal shading with the option of applying prognostic climatic control. Generally, the findings highlight the importance of dynamics in controlling functions and the difficulty of incorporating in models unpredictable factors as the solar radiation. (c) 2005 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:547 / 555
页数:9
相关论文
共 50 条
  • [41] Experimental study on heating characteristics and control strategies of ground source heat pump and radiant floor heating system in an office building
    Zhang, Linhua
    Huang, Xiaokai
    Liang, Li
    Liu, Jiying
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 4060 - 4066
  • [42] Capacity Configuration and Operation Optimization of a Low-Temperature Reactor Nuclear Heating System with Heat Storage
    Liu, Weiqi
    Wang, Jinshi
    Xue, Kai
    Sun, Zhiyong
    Liu, Xingmin
    Li, Gen
    Yan, Junjie
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (04): : 213 - 220
  • [43] A Totally Heat-Driven Refrigeration System Using Low-Temperature Heat Sources for Low-Temperature Applications
    Seyfouri, Zeynab
    Ameri, Mehran
    Mehrabian, Mozaffar Ali
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2019, 27 (02)
  • [44] HIGH-TEMPERATURE HEAT PUMP INTEGRATION INTO DISTRICT HEATING SYSTEM
    Jakovleva, Ludmila
    [J]. 20TH INTERNATIONAL SCIENTIFIC CONFERENCE ENGINEERING FOR RURAL DEVELOPMENT, 2021, : 1312 - 1316
  • [45] Towards energy-use optimisation of a domestic heating system based on a heat pump
    Sakellari, D
    Lundqvist, P
    [J]. STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2001, 47 (08): : 506 - 511
  • [46] Towards energy-use optimisation of a domestic heating system based on a heat pump
    Sakellari, D
    Lundqvist, P
    [J]. THERMAL SCIENCES 2000, 2000, : 549 - 554
  • [47] Towards energy-use optimisation of a domestic heating system based on a heat pump
    Sakellari, Dimitra
    Lundqvist, Per
    [J]. 2001, Assoc. of Mechanical Eng. and Technicians of Slovenia (47):
  • [48] Modelling and simulation results for a domestic exhaust-air heat pump heating system
    Sakellari, D
    Lundqvist, P
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (07): : 1048 - 1056
  • [49] A DOMESTIC SOLAR/HEAT PUMP HEATING SYSTEM INCORPORATING LATENT AND STRATIFIED THERMAL STORAGE
    Trinkl, Christoph
    Zoerner, Wilfried
    Hanby, Vic
    [J]. ES2008: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 611 - 620
  • [50] EXERGY ANALYSIS AND EXPERIMENTAL STUDY OF HEAT PUMP COUPLED REVERSIBLY USED COOLING TOWER IN LOW-TEMPERATURE HEATING MODE
    Wu, J. S.
    Zhang, G. Q.
    Zhang, Q.
    Zhou, J.
    Guo, Y. H.
    Shen, W.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 198 - 203